Overview
| res_sf | lot-size-encoded (R-200 = min 20,000 SF; R-90 = min 9,000 SF; R-60 = min 6,000 SF; RE series = large estate lots) |
|---|---|
| res_mf | density-encoded (RT-8.0/10.0/12.5 = du/ac; R-30/R-20 = density-based multifamily) |
| com | letter-code with FAR suffix (CRT-2.0, CRN-0.75, NR-0.75, PCC, PRC) |
Montgomery County Chapter 59 (2014). Olney is governed entirely by county zoning; no municipal code exists. The 2005 Olney Master Plan guides zone application in the Olney Town Center area (CRT, CRN, NR) and recommends RNC zoning for peripheral conservation parcels (e.g. former Norbeck Country Club site). PD zones (PD-3, PD-7, PD-9) are Planned Development floating zones applied to specific projects.
- Olney is an UNINCORPORATED CDP — no municipal government, mayor, or city council. Montgomery County is the zoning authority under Chapter 59 (eff. 2014-10-30). The stub at code_source previously pointed to library.municode.com/md/olney which is incorrect (Olney has no municipal code).
- The 2005 Olney Master Plan recommended the Mixed-Use Town Center concept for the Georgia Ave / Route 108 core, implemented through CRT and CRN zone designations. It also recommended RNC zoning for the former Norbeck Country Club site (~38 RNC parcels now mapped).
- The Montgomery County Chapter 59 zoning ordinance (2014 comprehensive rewrite effective 2014-10-30) replaced the pre-2014 zoning code. PCC (Planned Convenience Center) and PRC (Planned Retail Center) are legacy floating zones carried forward from the old code and still appear on the Olney zoning map.
+ 3 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RE-2 | Residential Estate - 2 Zone | res_sf | 87,120 sf[4] | 50 ft[5] | 25[6] | — | 0.5[7] | — | 50[1] / 17[2] / 35[3] |
| RE-2C | Residential Estate - 2C Zone | res_sf | 87,120 sf[11] | 50 ft[12] | 25[13] | — | —[14] | — | 50[8] / 17[9] / 35[10] |
| RE-1 | Residential Estate - 1 Zone | res_sf | 40,000 sf[18] | 50 ft[19] | 15[20] | — | 1.09[21] | — | 50[15] / 17[16] / 35[17] |
| R-200 | Residential - 200 Zone | res_sf | 20,000 sf[25] | 50 ft[26] | 25[27] | — | 2.18[28] | 2[29] | 40[22] / 12[23] / 30[24] |
| R-90 | Residential - 90 Zone | res_sf | 9,000 sf[33] | 35 ft[34] | 30[35] | — | 4.84[36] | — | 30[30] / 8[31] / 25[32] |
| R-60 | Residential - 60 Zone | res_sf | 6,000 sf[40] | 35 ft[41] | 35[42] | — | 7.26[43] | — | 25[37] / 8[38] / 20[39] |
| RNC | Rural Neighborhood Cluster Zone | res_sf | 25,000 sf[47] | 35 ft[48] | 10[49] | — | 0.2[50] | — | 40[44] / 15[45] / 35[46] |
| RC | Rural Cluster Zone | res_sf | — | — | — | — | — | — | — / — / — |
| AR | Agricultural Reserve Zone | ag | 40,000 sf[51] | — | 10[52] | — | —[53] | — | — / — / — |
| RT-8.0 | Residential Townhouse - 8.0 Zone | res_th | — | — | — | — | 8[54] | — | — / — / — |
| RT-10.0 | Residential Townhouse - 10.0 Zone | res_th | — | — | — | — | 10[55] | — | — / — / — |
| RT-12.5 | Residential Townhouse - 12.5 Zone | res_th | — | — | — | — | 12.5[56] | — | — / — / — |
| R-30 | Residential Multi-Unit Low Density - 30 Zone | res_mf | — | — | — | — | — | — | — / — / — |
| R-20 | Residential Multi-Unit Medium Density - 20 Zone | res_mf | — | — | — | — | — | — | — / — / — |
| PD-3 | Planned Development - 3 Zone | spec | — | — | — | — | 3[57] | — | — / — / — |
| PD-7 | Planned Development - 7 Zone | spec | — | — | — | — | 7[58] | — | — / — / — |
| PD-9 | Planned Development - 9 Zone | spec | — | — | — | — | 9[59] | — | — / — / — |
| CRT-2.0 | Commercial/Residential Town - 2.0 FAR | mu | — | —[60] | — | 2[61] | — | — | — / — / — |
| CRT-0.75 | Commercial/Residential Town - 0.75 FAR | mu | — | —[62] | — | 0.75[63] | — | — | — / — / — |
| CRT-0.25 | Commercial/Residential Town - 0.25 FAR | mu | — | —[64] | — | 0.25[65] | — | — | — / — / — |
| CRN-0.75 | Commercial/Residential Neighborhood - 0.75 FAR | mu | — | —[66] | — | 0.75[67] | — | — | — / — / — |
| CRN-0.5 | Commercial/Residential Neighborhood - 0.5 FAR | mu | — | —[68] | — | 0.5[69] | — | — | — / — / — |
| NR-0.75 | Neighborhood Retail - 0.75 FAR | com | — | — | — | 0.75[70] | — | — | — / — / — |
| PCC | Planned Convenience Center | com | — | — | — | — | — | — | — / — / — |
| PRC | Planned Retail Center | com | — | — | — | — | — | — | — / — / — |
| EOF-1.5 | Employment Office Flex - 1.5 FAR | off | — | — | — | 1.5[71] | — | — | — / — / — |
| RURAL | Rural Zone | ag | — | — | — | — | — | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Olney Town Center area centered on intersection of Georgia Avenue (MD-97) and Route 108 in Olney CDP
| description | The 2005 Olney Master Plan guides zone designations in the town center; it recommended CRT zones (mixed-use to 1.0 FAR and 20 du/ac) for the core, RNC zoning for peripheral conservation parcels (former Norbeck Country Club), and open space preservation. The plan established the Olney Town Center Advisory Committee (OTCAC). Not a separate overlay in the Ch.59 code — rather, master plan guidance is implemented through underlying zone assignments. |
|---|---|
| max_far_in_core | 1.0 (CRT-2.0 zone with mapped C/R/H limits) |
| density_in_core_du_ac | 20 (as recommended by master plan) |
FEMA-mapped Special Flood Hazard Areas (Zone AE, Zone A) along Brooke Farm Creek, Laytonsville Branch, and unnamed tributaries within Olney CDP
| base_flood_elevation | per FEMA FIRM panels for Montgomery County MD |
|---|---|
| local_freeboard | not_found — Montgomery County freeboard above BFE not stated in available sources |
| fema_firm_status | adopted |
Individually designated historic sites and districts within Olney CDP as listed on the Montgomery County Master Plan for Historic Preservation and/or National Register
| designation_authority | Historic Preservation Commission (HPC) of Montgomery County |
|---|---|
| review_required | Demolition and alteration permits for designated resources require HPC approval |
| sandy_spring_olney_historic_district | Sandy Spring/Olney Rural Historic District listed on National Register; boundaries partially overlap Olney CDP |
Regulated stream buffers along Brooke Farm Creek and other tributaries in Olney CDP; stream classification per MD DNR
| buffer_width | 25-100 ft depending on stream classification per §Ch.22B |
|---|---|
| vegetated_buffer_required | True |
Applies to qualifying parcels within 0.75 mi of MARC/Metro/light rail station OR within 0.5 mi of qualifying high-frequency bus service. Olney has no rail station; high-frequency bus trigger must be evaluated per parcel.
| rail_station_present | False |
|---|---|
| high_frequency_bus_assessment | Olney is served by RideOn Route 60 and Ride On connections at Georgia Ave/Route 108; frequency threshold (qualifying high-frequency bus) must be verified against HEAA implementing regulations — not confirmed in this research pass |
| density_floor_if_triggered_du_ac | 15 |
| max_parking_per_unit_if_triggered | 1 |
State preemptions
Non-applicable laws (3)
Adopted building codes
Statewide w/ local amendments
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2014-10-30 | effective | Chapter 59 header: 'October 30, 2014' effective date stamped on each section (e.g. §4.3.5, §4.4.8) |
| 2014-03-04 | adoption | Montgomery County Council adoption, spring 2014; Chapter 59 comprehensive rewrite |
Quirks & notes
- Olney is an UNINCORPORATED CDP — no municipal government, mayor, or city council. Montgomery County is the zoning authority under Chapter 59 (eff. 2014-10-30). The stub at code_source previously pointed to library.municode.com/md/olney which is incorrect (Olney has no municipal code).
- The 2005 Olney Master Plan recommended the Mixed-Use Town Center concept for the Georgia Ave / Route 108 core, implemented through CRT and CRN zone designations. It also recommended RNC zoning for the former Norbeck Country Club site (~38 RNC parcels now mapped).
- The Montgomery County Chapter 59 zoning ordinance (2014 comprehensive rewrite effective 2014-10-30) replaced the pre-2014 zoning code. PCC (Planned Convenience Center) and PRC (Planned Retail Center) are legacy floating zones carried forward from the old code and still appear on the Olney zoning map.
- CRT and CRN zones use a composite notation on the zoning map showing four values: total FAR, C-FAR (nonresidential), R-FAR (residential), H (height in feet). The zone suffix in the database (e.g. CRT-2.0) captures only the total FAR; the full C/R/H designation is map-specific.
- The Sandy Spring/Olney Rural Historic District is listed on the National Register of Historic Places; portions of this district overlap the Olney CDP boundary. Montgomery County Chapter 24A governs local HP review; HPC approval required for demolition and major alteration of designated resources.
- GIS source verified: https://mcatlas.org/arcgis5/rest/services/backgrounds/Zoning_background/MapServer/27 — HTTP 200, 8,567 total features, Olney bbox (39.094–39.194, -77.121–-77.021) returned 593 features with 26 distinct zone codes; sample centroid within 1.5° of Olney centroid (-77.071, 39.144).
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §4.4.4 RE-2 Front setback 50'
- [2] §4.4.4 RE-2 Side setback (min) 17'; sum 35'
- [3] §4.4.4 RE-2 Rear setback 35'
- [4] §4.4.4 RE-2 Lot Area min 2 acres (87,120 SF); Montgomery Planning RE-2 Fact Sheet 9-16-14
- [5] §4.4.4 RE-2 Principal Building max height 50'
- [6] §4.4.4 RE-2 Coverage max 25%
- [7] i§4.4.4 RE-2 2-acre minimum = max ~0.5 du/ac (implied; no explicit du/ac stated in standards)
- [8] §4.4.5 RE-2C Front setback 50'
- [9] §4.4.5 RE-2C Side setback 17'; sum 35'
- [10] §4.4.5 RE-2C Rear setback 35'
- [11] §4.4.5 RE-2C Lot Area min 2 acres; Montgomery Planning RE2CZoningFactSheet 9-16-14
- [12] §4.4.5 RE-2C Principal Building max height 50'
- [13] §4.4.5 RE-2C Coverage max 25%
- [14] i§4.4.5 RE-2C Standard method: density 1 lot/5 acres max; cluster form on 5-acre minimum site
- [15] §4.4.3 RE-1 Front setback 50'
- [16] §4.4.3 RE-1 Side setback 17'; sum 35'
- [17] §4.4.3 RE-1 Rear setback 35'
- [18] §4.4.3 RE-1 Lot Area min 40,000 SF; Montgomery Planning RE1ZoningFactSheet 9-16-14
- [19] §4.4.3 RE-1 Principal Building max height 50'
- [20] §4.4.3 RE-1 Coverage max 15% (all roofed structures)
- [21] i§4.4.3 RE-1 40,000 SF lot yields ~1.09 du/ac max (implied from lot area)
- [22] §4.4.7 R-200 Minimum setback from street 40'
- [23] §4.4.7 R-200 Minimum side yard 12'; sum of 2 side yards 25'
- [24] §4.4.7 R-200 Minimum rear yard 30'
- [25] §4.4.7 R-200 Lot area min 20,000 SF (0.45 acres); Montgomery Planning R200.pdf fact sheet
- [26] §4.4.7 R-200 Maximum building height 50 ft
- [27] §4.4.7 R-200 Maximum building coverage 25%
- [28] §4.4.7 R-200 yields max 2.18 units/acre (stated on fact sheet)
- [29] §4.4.7 R-200 Parking: 2 off-street spaces/dwelling unit
- [30] §4.4.8 R-90 Front setback 30'
- [31] §4.4.8 R-90 Side setback (min) 8'; sum 25'
- [32] §4.4.8 R-90 Rear setback 25'
- [33] §4.4.8 R-90 Lot area min 9,000 SF; Wayback amlegal 0-0-0-60200
- [34] §4.4.8 R-90 Principal building max height 35' (flat roof) / 30' (to mean of gable); 40' if PB site plan
- [35] §4.4.8 R-90 Coverage max 30%
- [36] §4.4.8 R-90 Density max 4.84 units/acre
- [37] §4.4.9 R-60 Front setback 25'
- [38] §4.4.9 R-60 Side setback (min) 8'; sum 18'
- [39] §4.4.9 R-60 Rear setback 20'
- [40] §4.4.9 R-60 Lot area min 6,000 SF; Wayback amlegal 0-0-0-60201
- [41] §4.4.9 R-60 Principal building max 35' flat roof / 30' mean gable; 40' if PB site plan
- [42] §4.4.9 R-60 Coverage max 35%
- [43] §4.4.9 R-60 Density max 7.26 units/acre
- [44] §4.3.5 RNC Front setback (public street) 40'
- [45] §4.3.5 RNC Side setback 15'
- [46] §4.3.5 RNC Rear setback 35'
- [47] §4.3.5 RNC Lot area min 25,000 SF (detached house); DevelopmentStandardsForRncZone.pdf
- [48] §4.3.5 RNC Principal building max height 35'
- [49] §4.3.5 RNC Lot coverage max 10% (detached house)
- [50] §4.3.5 RNC Density max 1 lot per 5 acres (0.2 du/ac); 60% open space requirement
- [51] §4.2.3 AR Lot area min 40,000 SF (child lot max 3 acres); DevelopmentStandardsForArZone.pdf
- [52] §4.2.3 AR Coverage max 10%; up to 40% for greenhouse-dominant use with site plan
- [53] §4.2.3 AR Density 1 lot per 25 acres; only child lots (≤3 ac) and voluntary conservation lots permitted
- [54] §8.2.4 RT-8.0 The number suffix encodes max du/ac; 8.0 du/ac maximum for this designation
- [55] §8.2.4 RT-10.0 Number suffix = max du/ac; 10.0 du/ac maximum
- [56] §8.2.4 RT-12.5 Number suffix = max du/ac; 12.5 du/ac maximum
- [57] i§59-D-4 PD zone density approximated from PD number designation
- [58] i§59-D-4 PD zone density approximated from PD number
- [59] i§59-D-4 PD zone density approximated from PD number
- [60] i§4.5 CRT zone height range 35-150ft; specific height mapped per zone designation (CRT-2.0 map designation sets specific H value)
- [61] §4.5.2 CRT-2.0 Maximum total FAR 2.0 (the number suffix = total FAR cap)
- [62] i§4.5 CRT height range 35-150ft; specific H value set on zoning map designation
- [63] §4.5.2 CRT-0.75 Maximum total FAR 0.75
- [64] i§4.5 CRT height range 35-150ft; H value on zoning map
- [65] §4.5.2 CRT-0.25 Maximum total FAR 0.25; note: ZTA 14-09 made 0.25 FAR a valid CRT floor
- [66] i§4.5 CRN height range 25-65ft; specific H mapped on zoning designation
- [67] §4.5.2 CRN-0.75 Maximum total FAR 0.75; CRN range 0.25-1.5 FAR
- [68] i§4.5 CRN height range 25-65ft
- [69] §4.5.2 CRN-0.5 Maximum total FAR 0.5; CRN range 0.25-1.5 FAR
- [70] i§4.6 NR-0.75 Maximum total FAR 0.75 (number suffix = FAR cap for NR family)
- [71] i§4.7 EOF-1.5 Number suffix = total FAR cap; Employment zone family
Research status
Publication gates
| primary url present | passed | code_source = https://codelibrary.amlegal.com/codes/montgomerycounty/latest/montgomeryco_md_zone2014/0-0-0-1 — starts with https://, not an aggregator domain |
|---|---|---|
| no aggregator cited | passed | scan clean — no zoneomics, steadily, siteplanguide, sitedesignguide, siteplancreator, propwire, zonara, or unzoned domains cited |
| confidence tags full form | passed | 22 confirmed fields carry §-citations (e.g. c§4.4.7, c§4.4.8, c§4.4.9, c§4.3.5, c§4.5.2); all c-tagged values cite §-reference per Gate 3 |
| overlays have parameters trigger confidence | passed | 5 overlays, all have non-empty params, trigger, status, and confidence fields |
| preempt section city specific | passed | MD is not an active-preemption state; Gate 5 does not require non-empty state_preemptions_applicable array. 4 laws evaluated with city-specific qualifying_condition_checked for Olney CDP context |
Data quality
- RC zone dimensional standards not retrieved
- RT zone (RT-8.0, RT-10.0, RT-12.5) full dimensional standards not retrieved — Article 8 floating zones
- R-30 and R-20 dimensional standards not retrieved (Wayback returned 404 for sections 60215/60217)
- PCC and PRC legacy zone dimensional standards not retrieved
- NR zone height and setback standards not retrieved
- EOF zone height standards not retrieved
- Rural zone dimensional standards not retrieved
- CRT and CRN specific H values on zoning map not extracted (require per-parcel map lookup)
- HEAA high-frequency bus trigger for Olney RideOn service not verified against implementing regulations
Other cities in this state