Overview
| res_sf | lot-size-encoded (R-200=20,000 sf min; R-90=9,000 sf min; R-60=6,000 sf min) |
|---|---|
| res_mf | density-encoded (R-30=3,000 sf/du; R-20=2,000 sf/du; R-10=1,000 sf/du) |
| res_th | density-encoded (TLD=8 du/ac; TMD=10-12.5 du/ac; THD=15 du/ac) |
| mu | FAR-encoded with subtype prefix (CR-4.0, CRT-2.0, CRN-1.0) |
| ind | FAR-encoded with subtype prefix (IL-1.0, IM-2.5) |
| off | FAR-encoded (EOF-3.0, LSC-1.0) |
Silver Spring is an unincorporated CDP governed entirely by Montgomery County Zoning Ordinance Chapter 59 (effective 2014-10-30), administered by M-NCPPC. No municipal zoning. Downtown Silver Spring around the Metro has CR/CRT commercial-residential zones plus the DSS Overlay Zone and Fenton Village Overlay. Nomenclature for CR/CRT/CRN zones: number after dash = maximum total FAR; individual lot maps also carry C (commercial) FAR, R (residential) FAR, and H (height-ft) designations.
- Silver Spring is an unincorporated CDP — no municipal government. All zoning authority resides with Montgomery County, administered by the Maryland-National Capital Park and Planning Commission (M-NCPPC). Montgomery County Code Chapter 59 is the sole zoning ordinance.
- CR/CRT/CRN zones use a compound notation: the base code (e.g., CRT) is followed by a total FAR number (e.g., CRT-2.0). Individual parcels on the Sectional Map Amendment also carry C FAR, R FAR, and H (max height in feet) designators. The zoning map must be consulted for site-specific limits within the CR family.
- Downtown Silver Spring around the WMATA Red Line Metro station is in the DSS (Downtown Silver Spring) Overlay Zone (§4.9.8, codified via ZTA 22-03). The DSS Overlay supersedes the former Ripley/South Silver Spring (RSS) Overlay, which was deleted in 2022. The Fenton Village (FV) Overlay Zone (§4.9.8 pre-ZTA-22-03 numbering; now §4.9.9) applies to the Fenton Street corridor.
+ 3 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RE-2 | Residential Estate — 2 Acres | res_sf | 87,120 sf[2] | 35 ft[3] | —[4] | — | —[5] | — | —[1] / — / — |
| RE-2C | Residential Estate — 2 Acres Cluster | res_sf | 87,120 sf[6] | 35 ft[7] | —[8] | — | — | — | — / — / — |
| RE-1 | Residential Estate — 1 Acre (40,000 sf) | res_sf | 40,000 sf[9] | 35 ft[10] | —[11] | — | — | — | — / — / — |
| R-200 | Residential — 200 (20,000 sf) | res_sf | 20,000 sf[12] | 35 ft[13] | —[14] | — | — | — | — / — / — |
| R-90 | Residential — 90 (9,000 sf) | res_sf | 9,000 sf[18] | 35 ft[19] | 30[20] | — | — | — | 30[15] / 8[16] / 25[17] |
| R-60 | Residential — 60 (6,000 sf) | res_sf | 6,000 sf[24] | 35 ft[25] | 35[26] | — | — | — | 25[21] / 8[22] / 20[23] |
| R-30 | Residential Multi-Unit Low Density — 30 | res_mf | 12,000 sf[27] | —[28] | —[29] | — | —[30] | — | — / — / — |
| R-20 | Residential Multi-Unit Medium Density — 20 | res_mf | 16,000 sf[31] | —[32] | — | — | —[33] | — | — / — / — |
| R-10 | Residential Multi-Unit High Density — 10 | res_mf | 20,000 sf[34] | —[35] | — | — | —[36] | — | — / — / — |
| TLD | Townhouse Low Density | res_th | —[37] | —[38] | — | — | 8[39] | — | — / — / — |
| TMD | Townhouse Medium Density | res_th | —[40] | —[41] | — | — | 12.5[42] | — | — / — / — |
| THD | Townhouse High Density | res_th | 40,000 sf[43] | —[44] | — | — | 15[45] | — | — / — / — |
| CRN | Commercial/Residential Neighborhood | mu | — | [{'variant': 'min', 'value': 25}, {'variant': 'max', 'value': 65}] ft[47] | — | [{'variant': 'min', 'value': 0.25}, {'variant': 'max', 'value': 1.5}][48] | —[49] | — | —[46] / — / — |
| CRT | Commercial/Residential Town Center | mu | — | [{'variant': 'min', 'value': 35}, {'variant': 'max', 'value': 150}] ft[51] | — | [{'variant': 'min', 'value': 0.25}, {'variant': 'max', 'value': 4.0}][52] | —[53] | — | —[50] / — / — |
| CR | Commercial/Residential | mu | — | [{'variant': 'min', 'value': 35}, {'variant': 'max', 'value': 300}] ft[54] | — | [{'variant': 'min', 'value': 0.5}, {'variant': 'max', 'value': 8.0}][55] | —[56] | — | — / — / — |
| EOF | Employment Office | off | — | [{'variant': 'min', 'value': 35}, {'variant': 'max', 'value': 200}] ft[57] | — | [{'variant': 'min', 'value': 0.5}, {'variant': 'max', 'value': 4.0}][58] | — | — | — / — / — |
| GR | General Retail | com | — | —[59] | — | 1.5[60] | — | — | — / — / — |
| LSC | Life Science Center | off | — | [{'variant': 'min', 'value': 35}, {'variant': 'max', 'value': 200}] ft[61] | — | [{'variant': 'min', 'value': 0.5}, {'variant': 'max', 'value': 2.5}][62] | — | — | — / — / — |
| IL | Industrial Light | ind | — | —[63] | — | 1[64] | — | — | — / — / — |
| IM | Industrial Moderate | ind | — | —[65] | — | [{'variant': 'IM-1.5', 'value': 1.5}, {'variant': 'IM-2.5', 'value': 2.5}][66] | — | — | — / — / — |
| PRC | Planned Retirement Community | spec | — | —[67] | — | — | —[68] | — | — / — / — |
| PD | Planned Development | spec | — | —[69] | — | — | —[70] | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
All properties within the Downtown Silver Spring downtown plan districts as defined in the Silver Spring Downtown and Adjacent Communities (SSDAC) Sector Plan — entire downtown plan area except the Adjacent Communities district. Applied via Sectional Map Amendment.
| purpose | Implements SSDAC Sector Plan recommendations for land use, density, height, affordability, design, and public open space |
|---|---|
| mpdu_required_pct | 15 |
| mpdu_threshold_units | 20 |
| mpdu_statute | Chapter 25A Montgomery County Code |
| height_incentive_area | Specific parcels in Height Incentive Area may receive up to 150% of mapped height (max 300 ft) for optional method development with MPDUs >15%, Housing Initiative Fund contribution, or activating ground-floor uses; select SSDAC-recommended parcels may reach 360 ft |
| density_bonus | CR zone 8.0 FAR parcels: not subject to C FAR or R FAR sub-limits; excess FAR via DSS Density mechanism requires $5/sf Civic Improvement Fund contribution |
| design_review | Silver Spring Design Advisory Panel review required for projects seeking additional height |
| public_benefits | Min 10 points exceptional design required; transit proximity and structured parking excluded from public benefit point calculation |
| land_use_additions | Light manufacturing for food production and rooftop urban farming permitted as accessory uses in CR zone |
| fenton_village_nested | Fenton Village (FV) Overlay Zone is a nested sub-overlay within the DSS Overlay Zone area |
Properties along the Fenton Street corridor in downtown Silver Spring, as defined by the FV Overlay Sectional Map Amendment boundary; boundaries expanded slightly east per ZTA 22-03
| purpose | Facilitates organized, cohesive development pattern appropriate for urban environment; encourages attractive design; ensures compatibility |
|---|---|
| retail_bay_limit | Retail bays limited to 60-ft facade width (exception for grocery stores and basement-level retailers) |
| small_bay_requirement | Developments with retail must provide two small bays: one under 1,200 sf and one under 2,000 sf |
| major_highway | Georgia Avenue |
| eastern_road | Fenton Street |
| nested_within_DSS | The FV Overlay Zone falls within the larger DSS Overlay Zone area |
Properties within 0.75 mile (3,960 ft) of Silver Spring WMATA Red Line / MARC Brunswick Line station — a qualifying frequent-rail station under HEAA §7-503
| density_floor_du_ac | 15 |
|---|---|
| density_within_0.25mi_rail | 30 |
| parking_maximum_per_unit | 1 |
| parking_within_0.25mi_rail | 0 |
| affordability_required_pct | 15 |
| affordability_ami_cap | 60 |
| affordability_term_rental_years | 40 |
| affordability_term_forsale_years | 30 |
| density_bonus_pct | 30 |
| by_right | True |
| critical_area_carveout | HEAA does not override Chesapeake Bay Critical Area Program; LDA and RCA caps control inside the 1,000-ft Critical Area — not applicable to Silver Spring (not in Critical Area) |
Properties within FEMA-designated Special Flood Hazard Area (SFHA) as shown on FIRM panels for Montgomery County; particularly along Sligo Creek and tributaries within Silver Spring CDP
| nfip_participant | Montgomery County participates in NFIP |
|---|---|
| freeboard_ft | — |
| floodway_encroachment | No new development permitted in regulatory floodway |
| sfha_requirement | Structures must meet BFE+freeboard requirements per Chapter 19 |
Statewide — applies to all residential zones in Montgomery County including Silver Spring CDP
| adu_by_right | True |
|---|---|
| local_implementation_deadline | 2026-10-01 |
| note | DLS codified LU section not yet published as of research date; tracked as bill-named per preemptions.json |
State preemptions
Non-applicable laws (2)
Adopted building codes
Statewide w/ local amendments
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-02-03 | last amended | Montgomery County Zoning Ordinance current version as of 2026-02-03 per montgomeryplanning.org |
| 2014-10-30 | effective | ZTA 14-09, Chapter 59 Zoning Ordinance 2014 — County Council adoption spring 2014, effective October 30, 2014 |
Quirks & notes
- Silver Spring is an unincorporated CDP — no municipal government. All zoning authority resides with Montgomery County, administered by the Maryland-National Capital Park and Planning Commission (M-NCPPC). Montgomery County Code Chapter 59 is the sole zoning ordinance.
- CR/CRT/CRN zones use a compound notation: the base code (e.g., CRT) is followed by a total FAR number (e.g., CRT-2.0). Individual parcels on the Sectional Map Amendment also carry C FAR, R FAR, and H (max height in feet) designators. The zoning map must be consulted for site-specific limits within the CR family.
- Downtown Silver Spring around the WMATA Red Line Metro station is in the DSS (Downtown Silver Spring) Overlay Zone (§4.9.8, codified via ZTA 22-03). The DSS Overlay supersedes the former Ripley/South Silver Spring (RSS) Overlay, which was deleted in 2022. The Fenton Village (FV) Overlay Zone (§4.9.8 pre-ZTA-22-03 numbering; now §4.9.9) applies to the Fenton Street corridor.
- Residential Townhouse zones in Silver Spring use the 2014-code TLD/TMD/THD designations, which replaced the legacy RT-6/RT-8/RT-10/RT-12.5/RT-15 floating zones. Both legacy RT and new T-family codes appear on maps because conversion was phased via Sectional Map Amendments.
- Silver Spring has large swaths of R-60 (6,000 sf min lot) single-family detached neighborhoods east and west of the downtown core, transitioning to R-90 further out. The CR-6.0 and CR-8.0 designations in the immediate downtown reflect the high-density transit-station development intent of the SSDAC Plan.
- HEAA 2024 (§7-501 to §7-508) applies: Silver Spring Metro (WMATA Red Line) is a qualifying rail station; properties within 0.75 mile (3,960 ft) of the station qualify for by-right multifamily at ≥15 du/ac with 15% MPDUs at ≤60% AMI. The Silver Spring Metro/MARC station at the core of the downtown puts most CR/CRT zones inside the TOD trigger radius.
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §4.4.6
- [2] §4.4.6 Ch.59 (2 acres × 43,560)
- [3] §4.4.6 Ch.59
- [4] §4.4.6
- [5] n§4.4.6
- [6] §4.4.6 Ch.59 (2 acres base)
- [7] §4.4 Ch.59
- [8] §4.4.6
- [9] §4.4.5 Ch.59 per montgomeryplanning.org/development/zoning/directory.shtm
- [10] §4.4 Ch.59
- [11] §4.4.5
- [12] §4.4.7 Ch.59; confirmed at montgomeryplanning.org/development/zoning/directory.shtm
- [13] §4.4.7 Ch.59
- [14] §4.4.7
- [15] §4.4.8 Ch.59 — DPS sheet: 30 ft or EBL whichever greater
- [16] §4.4.8 Ch.59 — DPS sheet: total 25 ft combined; one side min 8 ft
- [17] §4.4.8 Ch.59 — DPS sheet: 25 ft rear
- [18] §4.4.8 Ch.59 — DPS development standards sheet retrieved 2026-06-02
- [19] §4.4.8 Ch.59 — DPS sheet: 35 ft to roof peak or 30 ft mean height eaves/ridge
- [20] §4.4.8 Ch.59 — DPS sheet: 30% including accessory buildings
- [21] §4.4.9 Ch.59 — DPS sheet: 25 ft or EBL whichever greater
- [22] §4.4.9 Ch.59 — DPS sheet: total 18 ft combined; one side min 8 ft
- [23] §4.4.9 Ch.59 — DPS sheet: 20 ft rear
- [24] §4.4.9 Ch.59 — DPS development standards sheet retrieved 2026-06-02
- [25] §4.4.9 Ch.59 — DPS sheet: 35 ft to roof peak or 30 ft mean height eaves/ridge
- [26] §4.4.9 Ch.59 — DPS sheet: 35% including accessory buildings
- [27] §4.4.13 Ch.59 per montgomeryplanning.org/development/zoning/directory.shtm
- [28] §4.4.13
- [29] §4.4.13
- [30] §4.4.13
- [31] §4.4.14 Ch.59 per montgomeryplanning.org/development/zoning/directory.shtm
- [32] §4.4.14
- [33] §4.4.14
- [34] §4.4.16 Ch.59 per montgomeryplanning.org/development/zoning/directory.shtm
- [35] §4.4.16
- [36] §4.4.16
- [37] §4.4.17
- [38] §4.4.17
- [39] §4.4.17 Ch.59 per zoning directory: RT-8 = 8 du/ac equivalent
- [40] §4.4.18
- [41] §4.4.18
- [42] §4.4.18 Ch.59 per zoning directory: RT-12.5 = 12.5 du/ac equivalent
- [43] §4.4.19 Ch.59: minimum tract area 40,000 sf
- [44] §4.4.19
- [45] §4.4.19 Ch.59 per zoning directory: RT-15 = 15 du/ac equivalent
- [46] §4.5.3
- [47] §4.5.2 Ch.59 per ZTA 22-03 Table; montgomeryplanning.org CR zones
- [48] §4.5.2 Ch.59 per ZTA 22-03 Table; montgomeryplanning.org CR zones
- [49] §4.5.3
- [50] §4.5.3
- [51] §4.5.2 Ch.59 per ZTA 22-03 Table
- [52] §4.5.2 Ch.59 per ZTA 22-03 Table
- [53] §4.5.3
- [54] §4.5.2 Ch.59 per ZTA 22-03 Table; DSS Overlay §4.9.8 allows up to 360 ft on select parcels
- [55] §4.5.2 Ch.59 per ZTA 22-03 Table
- [56] §4.5.3
- [57] §4.6 Ch.59 per Montgomery Planning Employment Zones fact sheet
- [58] §4.6 Ch.59 per Montgomery Planning Employment Zones fact sheet
- [59] §4.6
- [60] §4.6 Ch.59 per GIS zone code GR-1.5
- [61] §4.6 Ch.59 per Montgomery Planning Employment Zones fact sheet
- [62] §4.6 Ch.59 per Montgomery Planning Employment Zones fact sheet
- [63] §4.7
- [64] §4.7 Ch.59 per GIS code IL-1.0; FAR from code suffix
- [65] §4.7
- [66] §4.7 Ch.59 per GIS codes IM-1.5 and IM-2.5
- [67] §4.8
- [68] §4.8 Ch.59
- [69] § PD-series
- [70] § PD-series Ch.59 legacy; numeric suffix = max du/ac per approved plans
Research status
Publication gates
| primary url present | passed | source.primary_url = https://montgomeryplanning.org/development/zoning/ — authoritative Montgomery County Planning Department domain; not an aggregator |
|---|---|---|
| no aggregator cited | passed | scan clean — no zoneomics, steadily, siteplanguide, propwire, zonara, unzoned, or siteplancreator references |
| confidence tags full form | passed | All confirmed (c) fields carry §-citations from Ch.59 or named section references. Partial (p) fields carry retrieval_failure_reason. 18 confirmed fields with full citations. |
| overlays have parameters trigger confidence | passed | 5 overlays: DSS (§4.9.8), FV (§4.9.9), HEAA-TOD (§7-501), FLOODPLAIN, HB1466-ADU — all have non-empty params, trigger, and confidence codes |
| preempt section city specific | passed | MD is not on Gate-5 active-preemption required list (CA/TX/FL/WA/OR/MT/CO/UT/AZ/NJ/CT). Preemptions section populated with 4 laws with city-specific qualifying_condition_checked. |
Data quality
- Height, setbacks, and lot coverage not captured for RE-2, RE-2C, RE-1, R-200 from primary source (DPS PDFs redirected and were binary; primary §4.4 tables not retrieved)
- Height, setbacks, lot coverage for R-30, R-20, R-10, TLD, TMD, THD not captured
- GR, IL, IM detailed standards (setbacks, coverage) not captured — zone code suffixes give FAR; H-designator from SMA parcel maps not retrieved
- CR/CRT/CRN setback details: complex setback regime per §4.5.3 (increases 1 ft/ft above max zone height) not fully documented
- PD zones: each approved plan has site-specific standards not in the ordinance text
- Floodplain freeboard for Montgomery County not confirmed from primary source
Other cities in this state