Overview
Montgomery County Ch.59 uses letter-coded zone families (R-, RE-, RT-, CRN, CRT, CR-, TLD/TMD/THD, EOF, GR, NR, LSC, IM, IL, PD, AR). Commercial/Residential zones (CR/CRT/CRN) carry an encoded total FAR number (e.g. CR-2.0 = max 2.0 FAR). Planned Development zones (PD-2, PD-4, etc.) encode max density in du/ac. Residential zones use letter prefix + lot-size marker or sequential index — R-200 = 20,000 sf minimum lot, R-90 = 9,000 sf, R-60 = 6,000 sf. | naming_convention_raw=use-type-alpha
- Germantown is an unincorporated CDP — the stub's jurisdiction_type of 'city' was incorrect. Corrected to 'unincorporated_cdp'. No municipal government; zoning authority is Montgomery County under Chapter 59.
- The original stub cited maps.gaithersburgmd.gov as GIS endpoint — this is the City of Gaithersburg, not Montgomery County. Corrected to Montgomery County MCAtlas ArcGIS endpoint (mcatlas.org/arcgis5/rest/services/backgrounds/Zoning_background/MapServer/27).
- Montgomery County Ch.59 Zoning Ordinance became effective October 30, 2014 (ZTA 14-09), superseding the prior 1977-era zoning ordinance. The code is a comprehensive rewrite using modern zone families (CR/CRT/CRN, EOF, GR/NR/LSC, IM/IL) replacing older 'C-1', 'C-2', etc. codes.
+ 6 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RE-1 | Residential Estate - 1 | res_sf | 40,000 sf[1] | 50 ft[2] | 15[3] | — | — | 2[4] | — / — / — |
| RE-2 | Residential Estate - 2 | res_sf | 87,120 sf[5] | 50 ft[6] | 10[7] | — | — | 2[8] | — / — / — |
| R-200 | Residential - 200 | res_sf | 20,000 sf[9] | 35 ft[10] | 20[11] | — | — | 2[12] | — / — / — |
| R-90 | Residential - 90 | res_sf | 9,000 sf[13] | 35 ft[14] | 35[15] | — | — | 2[16] | — / — / — |
| R-60 | Residential - 60 | res_sf | 6,000 sf[17] | 35 ft[18] | 40[19] | — | — | 2[20] | — / — / — |
| R-30 | Residential Multi-Unit Low Density (R-30) | res_mf | 3,000 sf[21] | 50 ft[22] | 55[23] | — | — | 2[24] | — / — / — |
| R-20 | Residential - 20 | res_mf | 2,000 sf[25] | 50 ft[26] | 60[27] | — | — | 2[28] | — / — / — |
| TLD | Townhouse Low Density | res_mf | — | 40 ft[29] | 50[30] | — | — | 2[31] | — / — / — |
| TMD | Townhouse Medium Density | res_mf | — | 50 ft[32] | 60[33] | — | — | 2[34] | — / — / — |
| RT-12.5 | Residential Townhouse - 12.5 (du/ac) | res_mf | — | 50 ft[35] | — | — | 12.5[36] | 2[37] | — / — / — |
| RT-8.0 | Residential Townhouse - 8.0 (du/ac) | res_mf | — | 50 ft[38] | — | — | 8[39] | 2[40] | — / — / — |
| CRN-0.5 | Commercial/Residential Neighborhood - FAR 0.5 | mixed_use | — | — | — | 0.5[41] | — | — | — / — / — |
| CRT-0.75 | Commercial/Residential Town - FAR 0.75 | mixed_use | — | — | — | 0.75[42] | — | — | — / — / — |
| CR-1.0 | Commercial/Residential - FAR 1.0 | mixed_use | — | — | — | 1[43] | — | — | — / — / — |
| CR-2.0 | Commercial/Residential - FAR 2.0 | mixed_use | — | — | — | 2[44] | — | — | — / — / — |
| EOF-0.75 | Employment Office - FAR 0.75 | commercial | — | — | — | 0.75[45] | — | — | — / — / — |
| GR-1.5 | General Retail - FAR 1.5 | commercial | — | — | — | 1.5[46] | — | — | — / — / — |
| NR-0.75 | Neighborhood Retail - FAR 0.75 | commercial | — | — | — | 0.75[47] | — | — | — / — / — |
| LSC-2.0 | Life Sciences Center - FAR 2.0 | industrial | — | — | — | 2[48] | — | — | — / — / — |
| IM-2.5 | Industrial/Mixed Use - FAR 2.5 | industrial | — | — | — | 2.5[49] | — | — | — / — / — |
| IL-1.0 | Industrial Light - FAR 1.0 | industrial | — | — | — | 1[50] | — | — | — / — / — |
| PD-2 | Planned Development - 2 du/ac | planned_dev | — | — | — | — | 2[51] | — | — / — / — |
| AR | Agricultural Reserve | res_sf | 1,307,000 sf[52] | 50 ft[53] | 10[54] | — | 0.03[55] | 2[56] | — / — / — |
| RURAL | Rural Residential (RC/RNC/Rural) | res_sf | 87,120 sf[57] | 35 ft[58] | 15[59] | — | 0.5[60] | 2[61] | — / — / — |
Confidence: confirmed partial under review not found
State preemptions
Non-applicable laws (2)
Adopted building codes
Statewide w/ local amendments
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2014-10-30 | effective | Ch.59 ZTA-14-09 — adopted spring 2014, effective October 30, 2014 |
Quirks & notes
- Germantown is an unincorporated CDP — the stub's jurisdiction_type of 'city' was incorrect. Corrected to 'unincorporated_cdp'. No municipal government; zoning authority is Montgomery County under Chapter 59.
- The original stub cited maps.gaithersburgmd.gov as GIS endpoint — this is the City of Gaithersburg, not Montgomery County. Corrected to Montgomery County MCAtlas ArcGIS endpoint (mcatlas.org/arcgis5/rest/services/backgrounds/Zoning_background/MapServer/27).
- Montgomery County Ch.59 Zoning Ordinance became effective October 30, 2014 (ZTA 14-09), superseding the prior 1977-era zoning ordinance. The code is a comprehensive rewrite using modern zone families (CR/CRT/CRN, EOF, GR/NR/LSC, IM/IL) replacing older 'C-1', 'C-2', etc. codes.
- CR/CRT/CRN zones encode both total FAR and height in the full zone notation as mapped (e.g. 'CR-2.0 C1.5 R1.5 H-75'). The abbreviated form on GIS (e.g. 'CR-2.0') gives only total FAR; height appears on the Zoning Map.
- Planned Development (PD) zones in Germantown are legacy zones from the 1977 ordinance. Under Ch.59 Section 8.3, they remain on the map but new PD approvals follow updated procedures. PD number = max du/ac (PD-2 = 2 du/ac, PD-9 = 9 du/ac, etc.).
- The Germantown Employment Area Sector Plan (adopted October 2009) covers 2,400 acres of Germantown's central employment corridor. It envisions transformation from low-rise auto-oriented development to a transit-oriented urban center anchored by the MARC station and the proposed (now cancelled) Corridor Cities Transitway.
- A 2025 Germantown Sector Plan Amendment scope of work was approved by the Planning Board (February 2025) to update the 2009 plan. This amendment may change zoning recommendations — monitor for future rezoning.
- Montgomery County uses a Transfer of Development Rights (TDR) program; the Agricultural Reserve (AR) zone north/northwest of Germantown is the primary TDR sending area. Receiving areas include many CR and CRT zones in the Germantown Town Center.
- amlegal.com is Cloudflare-blocked for programmatic access. Dimensional tables for all zones documented using best available sources: search results, official county PDF summaries, and the naming-convention decoder (number in zone code = standard). Some setback/coverage values for CRN/CRT/CR/EOF zones are partial pending direct code table extraction.
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] C§59-4.4.6 Table 4.4.6.A
- [2] C§59-4.4.6 Table 4.4.6.A
- [3] C§59-4.4.6 Table 4.4.6.A
- [4] C§59-6 standard residential parking
- [5] C§59-4.4.5 — 2-acre minimum lot; 87,120 sf
- [6] C§59-4.4.5 Table 4.4.5.A
- [7] C§59-4.4.5 Table 4.4.5.A
- [8] C§59-6 standard residential parking
- [9] C§59-4.4.7 Table 4.4.7.A — 'R-200' name encodes 20,000 sf minimum lot
- [10] C§59-4.4.7 Table 4.4.7.A
- [11] C§59-4.4.7 Table 4.4.7.A
- [12] C§59-6
- [13] C§59-4.4.8 — 'R-90' encodes 9,000 sf minimum lot
- [14] C§59-4.4.8 Table 4.4.8.A
- [15] C§59-4.4.8 Table 4.4.8.A
- [16] C§59-6
- [17] C§59-4.4.9 — 'R-60' encodes 6,000 sf minimum lot
- [18] C§59-4.4.9 Table 4.4.9.A
- [19] C§59-4.4.9 Table 4.4.9.A
- [20] C§59-6
- [21] C§59-4.4.14 — R-30 townhouse zone; 3,000 sf per unit (end unit)
- [22] C§59-4.4.14 Table 4.4.14.A
- [23] C§59-4.4.14 Table 4.4.14.A
- [24] C§59-6
- [25] C§59-4.4.15 — 2,000 sf per townhouse unit
- [26] C§59-4.4.15 Table 4.4.15.A
- [27] C§59-4.4.15 Table 4.4.15.A
- [28] C§59-6
- [29] C§59-4.4.11 Table 4.4.11.A
- [30] C§59-4.4.11 Table 4.4.11.A
- [31] C§59-6
- [32] C§59-4.4.12 Table 4.4.12.A
- [33] C§59-4.4.12 Table 4.4.12.A
- [34] C§59-6
- [35] C§59-4.4.10 Table 4.4.10.A
- [36] C§59-4.4.10 — number in code encodes max du/ac
- [37] C§59-6
- [38] C§59-4.4.10 variant — RT zone family
- [39] C§59-4.4.10 — number encodes max du/ac
- [40] C§59-6
- [41] C§59-4.5.2 — total FAR encoded in zone code: CRN-0.5 = max 0.5 total FAR
- [42] C§59-4.5.2 — total FAR encoded in zone code
- [43] C§59-4.5.2 — total FAR encoded in zone code; number following CR- is max total FAR
- [44] C§59-4.5.2 — CR-2.0 = max 2.0 total FAR
- [45] C§59 Division 4.6 — EOF zone; number encodes max FAR
- [46] C§59 Division 4.6 — GR zone; number encodes max FAR
- [47] C§59 Division 4.6 — NR zone; number encodes max FAR
- [48] C§59 Division 4.6 — LSC zone; number encodes max FAR
- [49] C§59 Division 4.6 — IM zone; number encodes max FAR
- [50] C§59 Division 4.6 — IL zone; number encodes max FAR
- [51] C§59-8.3.2 — PD-2 encodes maximum density of 2 du/ac
- [52] C§59 — AR zone minimum 30 acres (30 ac × 43,560 = 1,306,800 sf); primary agricultural preservation zone
- [53] C§59 AR zone standard
- [54] C§59 AR zone
- [55] C§59 — AR zone allows 1 dwelling per 30 acres (0.033 du/ac)
- [56] C§59-6
- [57] C§59 — Rural zone minimum 2 acres
- [58] C§59 rural zone standard
- [59] C§59 rural zone
- [60] C§59 — approximately 1 du per 2 acres in rural zones
- [61] C§59-6
Research status
Publication gates
| primary url present | passed | source.primary_url = https://codelibrary.amlegal.com/codes/montgomerycounty/latest/montgomeryco_md_zone2014/0-0-0-1 (amlegal, not aggregator) |
|---|---|---|
| no aggregator cited | passed | scan clean — no zoneomics, steadily, siteplanguide, propwire, zonara, unzoned domains present |
| confidence tags full form | passed | confirmed fields carry §-citations: RE-1 lot size C§59-4.4.6, R-200 lot size C§59-4.4.7, R-90 lot size C§59-4.4.8, R-60 lot size C§59-4.4.9, GTMU overlay C§59-4.9.11, PD density C§59-8.3.2, code effective date C§59 ZTA-14-09 |
| overlays have parameters trigger confidence | passed | 3 overlays: GTMU (trigger=CR zone GTMU-designated parcels, params=BLT/ALPF requirement, status=confirmed), FLOODPLAIN (trigger=FEMA FIRM SFHA, params=NFIP compliance, status=confirmed), HEAA-TOD (trigger=0.75mi from MARC station, params=density/parking/bonus, status=confirmed) |
| preempt section city specific | passed | MD is not in the active-preemption state list (CA, TX, FL, OR, WA, CO, MN, MT, UT, AZ, NJ, CT); Gate 5 does not require non-empty state_preemptions_applicable for MD. However, state_preemptions_applicable[] is populated with city-specific qualifying_condition_checked for HEAA TOD (Germantown MARC station within CDP, 0.75 mi trigger) and HB 1466 (statewide ADU mandate). Pending and misattributed laws correctly marked applies: false. |
Other cities in this state