Overview
Recode Knoxville replaced the prior 1962-era Chapter 16 ordinance effective 2020-01-01. The new code consolidates 27+ legacy districts into ~22 base districts plus form-based CU/SW and 6 overlays. EN preserves pre-1950 large-lot neighborhoods; RN-1..RN-7 ladder represents SF-large -> townhouse/MF. C-G/C-H/C-R use numeric suffix as form intensity tier (1=lowest, 3=highest). DK Downtown Knoxville uses subdistricts (DK-A through DK-W, etc.) rather than uniform standards. CU Cumberland Avenue and SW South Waterfront are full form-based-code districts in Article 7 with subdistricts. | naming_convention_raw=use-type-index plus modifier: EN/RN-#/C-N/C-G-#/C-H-#/C-R-#/O/OP/DK/I-MU/I-RD/I-G/I-H/CU/SW + overlays (H, NC, IH, TO-1, HP, F). RN-# number is intensity index (not lot size, not du/ac). C-G-#, C-H-#, C-R-# numerals are form-intensity tiers within same use family. ; sub_flags_raw=[modern-rewrite-2020, form-based-subset] ; narrative_ref=narratives/knoxville-tn/drain-20260518T072625-tn-05.json
- Recode Knoxville 2020 - clean-slate rewrite — Effective 2020-01-01, Recode Knoxville (Ord. O-281-2019) replaced the 1962-era Chapter 16 ordinance with a modern context-sensitive code. Pre-2020 v1 profile district codes (R-1A, R-1E, R-2, R-3, R-4, O-1/2/3, C-1 through C-7, C-G, I-2/3/4) are LEGACY and do not exist under Recode - replaced by EN/RN-1..RN-7, O/OP/DK, C-N/C-G-#/C-H-#/C-R-#, I-MU/I-RD/I-G/I-H, plus form-based CU/SW. — [Ord. O-281-2019 (adopted 2019-08-13, effective 2020-01-01); Appendix B Article 3]
- Blockface-average front setback (RN-1 through RN-6) — Front setback in RN-1 through RN-6 is the lesser of a fixed value (10', 20', or 25' depending on district) OR the average of the blockface. This is context-sensitive: in older neighborhoods with shallow lots, the existing pattern controls. EN uses '+/- 10' of average of blockface' with a 40' floor. — [Appendix B Article 4 Table 4-1 front setback rows]
- 20,000 sf min for non-sewered residential lots — All residential lots not served by sanitary sewer must be >= 20,000 sf, overriding district minimum if smaller. If district min > 20,000 sf (only EN at 22,000 sf), district min controls. — [Appendix B Article 4 §4.3.B]
+ 14 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| EN | Established Residential Neighborhood District | res_sf | 22,000 sf[4] | 35 ft[5] | 25[6] | — | — | — | 40[1] / —[2] / 25[3] |
| RN-1 | Single-Family Residential Neighborhood District | res_sf | 10,000 sf[10] | 35 ft[11] | 30[12] | — | — | — | 25[7] / —[8] / 25[9] |
| RN-2 | Single-Family Residential Neighborhood District (smaller-lot) | res_sf | 5,000 sf[16] | 35 ft[17] | 30[18] | — | — | — | 10[13] / —[14] / 25[15] |
| RN-3 | General Residential Neighborhood District (low-density mixed) | res_mf | 5,000 sf[22] | 35 ft[23] | 35[24] | — | — | — | 10[19] / —[20] / 25[21] |
| RN-4 | General Residential Neighborhood District (mixed residential) | res_mf | 5,000 sf[28] | [{'building_type': 'SF/2F/TH', 'v': 35, 'c': 'Appendix B Article 4 Table 4-1 (RN-4)'}, {'building_type': 'MF', 'v': 45, 'c': "Appendix B Article 4 Table 4-1 (RN-4; MF 45' unless adjacent to SFD, then 35')"}] ft | 35[29] | — | — | — | 10[25] / —[26] / 25[27] |
| RN-5 | General Residential Neighborhood District (heterogeneous mix) | res_mf | 5,000 sf[33] | 35 ft[34] | 35[35] | — | — | — | 25[30] / —[31] / 25[32] |
| RN-6 | Multi-Family Residential Neighborhood District | res_mf | 5,000 sf[37] | [{'building_type': 'SF/2F/TH', 'v': 35, 'c': 'Appendix B Article 4 Table 4-1 (RN-6)'}, {'building_type': 'MF', 'v': 65, 'c': 'Appendix B Article 4 Table 4-1 (RN-6)'}] ft | 40[38] | — | — | — | [{'building_type': "Structures <=35' tall", 'v': 25, 'c': "Appendix B Article 4 Table 4-1 (RN-6: 25' or average of blockface whichever is less)"}, {'building_type': "Structures >35' tall", 'v': 35, 'c': "Appendix B Article 4 Table 4-1 (RN-6: structures over 35' = 35' front)"}] / —[36] / [{'building_type': "Structures <=35' tall", 'v': 25, 'c': 'Appendix B Article 4 Table 4-1 (RN-6)'}, {'building_type': "Structures >35' tall", 'v': 30, 'c': 'Appendix B Article 4 Table 4-1 (RN-6)'}] |
| RN-7 | Multi-Family Residential Neighborhood District (most intense) | res_mf | 700 sf[41] | [{'building_type': 'TH', 'v': 35, 'c': 'Appendix B Article 4 Table 4-1 (RN-7)'}, {'building_type': 'MF', 'v': 65, 'c': 'Appendix B Article 4 Table 4-1 (RN-7)'}] ft | 50[42] | — | — | — | [{'building_type': 'TH', 'v': 25, 'c': "Appendix B Article 4 Table 4-1 (RN-7: TH 25' or average of blockface whichever is less)"}, {'building_type': 'MF', 'v': 35, 'c': "Appendix B Article 4 Table 4-1 (RN-7: MF 35'; reducible to 25' if no surface parking in front setback)"}] / —[39] / 30[40] |
| C-N | Neighborhood Commercial District | com | — | 45 ft[46] | — | — | — | — | 0[43] / —[44] / —[45] |
| C-G-1 | General Commercial District (low intensity) | com | — | 45 ft[50] | — | — | — | — | 0[47] / —[48] / —[49] |
| C-G-2 | General Commercial District (mid intensity, build-to) | com | — | 70 ft[54] | — | — | — | — | 0[51] / —[52] / —[53] |
| C-G-3 | General Commercial District (high intensity, build-to) | com | — | — | — | — | — | — | 0[55] / —[56] / —[57] |
| C-H-1 | Highway Commercial District (low intensity) | com | 10,000 sf[61] | 45 ft[62] | — | — | — | — | 20[58] / —[59] / —[60] |
| C-H-2 | Highway Commercial District (high intensity) | com | 10,000 sf[66] | 70 ft[67] | — | — | — | — | 20[63] / —[64] / —[65] |
| C-R-1 | Regional Commercial District (low intensity) | com | 15,000 sf[71] | 50 ft[72] | — | — | — | — | 20[68] / —[69] / —[70] |
| C-R-2 | Regional Commercial District (high intensity) | com | 15,000 sf[76] | 70 ft[77] | — | — | — | — | 20[73] / —[74] / —[75] |
| O | Office District | off | 10,000 sf[81] | 45 ft[82] | — | — | — | — | 15[78] / —[79] / —[80] |
| OP | Office Park District | off | 20,000 sf[86] | 50 ft[87] | — | — | — | — | 25[83] / —[84] / —[85] |
| DK | Downtown Knoxville District (multi-subdistrict) | mu | — | — | — | — | — | — | — / — / — |
| I-MU | Industrial Mixed-Use District | ind | — | 50 ft[91] | — | — | — | — | 0[88] / —[89] / 15[90] |
| I-RD | Research and Development District | ind | 87,120 sf[95] | 90 ft[96] | — | — | — | — | 50[92] / 40[93] / 30[94] |
| I-G | General Industrial District | ind | 10,000 sf[100] | 50 ft[101] | — | — | — | — | 25[97] / —[98] / —[99] |
| I-H | Heavy Industrial District | ind | 10,000 sf[105] | 50 ft[106] | — | — | — | — | 25[102] / —[103] / —[104] |
| CU | Cumberland Avenue Form-Based District | mu | — | — | — | — | — | — | — / — / — |
| SW | South Waterfront Form-Based District | mu | — | — | — | — | — | — | — / — / — |
| AG | General Agricultural District | spec | 217,800 sf[110] | 35 ft[111] | — | — | — | — | 35[107] / 35[108] / 35[109] |
| INST | Institutional District | spec | 20,000 sf[115] | 120 ft[116] | — | — | — | — | 20[112] / —[113] / —[114] |
| OS | Parks and Open Space District | spec | — | 35 ft[120] | 30[121] | — | — | — | 20[117] / —[118] / —[119] |
| NA | Natural Areas District | spec | 43,560 sf[125] | 35 ft[126] | — | — | — | — | 50[122] / 25[123] / —[124] |
Confidence: confirmed partial under review not found
Overlays
Geographically definable areas with significant concentration of sites/buildings of historical or architectural significance, designated by City Council on recommendation of Historic Zoning Commission (HZC) and Metropolitan Knoxville-Knox County Planning Commission per the 5 selection criteria of §8.5.E. Designated districts include Fort Sanders, Old North Knoxville, Mechanicsville, Edgewood-Park City, Fourth & Gill, and others on the Knoxville Historic Register.
Geographically definable areas with unifying built-environment characteristics, where general pattern of development (streets, lots, buildings) was established prior to 1950. Minimum 10 acres (less permitted if abutting existing NC Overlay). Designated by City Council on recommendation of HZC and Metropolitan Planning Commission.
Geographically definable areas in neighborhoods where houses and streets were generally established prior to 1950, with similar lot sizes/housing patterns/physical features. Minimum 10 acres (less permitted if abutting existing IH Overlay). Initiated by City Council, Mayor, owner, or majority of owners (51% petition allowed).
Tennessee Technology Corridor area of the City of Knoxville (Pellissippi Parkway corridor and adjacent properties), as defined by Private Chapter No. 148, Senate Bill No. 1230 of the Private Acts of 1983.
All lots within the HP Overlay District mapped boundaries (steep-slope areas of City). Existing single-family homes and existing lots of record for SFD as of effective date (2020-01-01) are exempt from density caps but still subject to maximum land-disturbance limitation.
Properties identified by FEMA as within Special Flood Hazard Areas (SFHA) per current Flood Insurance Rate Maps (FIRMs) for the City of Knoxville.
Knoxville is ~12 mi NE of McGhee Tyson Air National Guard Base (KTYS/Knoxville-McGhee Tyson Airport, also a 134th Air Refueling Wing facility). DoD AICUZ 65 DNL contours and FAA Part 77 surfaces extend into south Knox County and southern reaches of the City of Knoxville.
State preemptions
Non-applicable laws (1)
Adopted building codes
Major cities adopt newer locally
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- Recode Knoxville 2020 - clean-slate rewrite — Effective 2020-01-01, Recode Knoxville (Ord. O-281-2019) replaced the 1962-era Chapter 16 ordinance with a modern context-sensitive code. Pre-2020 v1 profile district codes (R-1A, R-1E, R-2, R-3, R-4, O-1/2/3, C-1 through C-7, C-G, I-2/3/4) are LEGACY and do not exist under Recode - replaced by EN/RN-1..RN-7, O/OP/DK, C-N/C-G-#/C-H-#/C-R-#, I-MU/I-RD/I-G/I-H, plus form-based CU/SW. — [Ord. O-281-2019 (adopted 2019-08-13, effective 2020-01-01); Appendix B Article 3]
- Blockface-average front setback (RN-1 through RN-6) — Front setback in RN-1 through RN-6 is the lesser of a fixed value (10', 20', or 25' depending on district) OR the average of the blockface. This is context-sensitive: in older neighborhoods with shallow lots, the existing pattern controls. EN uses '+/- 10' of average of blockface' with a 40' floor. — [Appendix B Article 4 Table 4-1 front setback rows]
- 20,000 sf min for non-sewered residential lots — All residential lots not served by sanitary sewer must be >= 20,000 sf, overriding district minimum if smaller. If district min > 20,000 sf (only EN at 22,000 sf), district min controls. — [Appendix B Article 4 §4.3.B]
- RN-7 MF building footprint cap (30,000 sf) + length cap (200') + multi-structure separation (35') — RN-7 (densest residential) imposes building geometry caps unusual in TN: max 30,000 sf footprint per individual MF structure, max 200' building length, minimum 35' between separate structures on the same lot. Designed to break up apartment-block massing. — [Appendix B Article 4 Table 4-1 (RN-7 column)]
- RN-6/RN-7 height-tiered side-setback stepback — RN-6 and RN-7 MF side setbacks step back 1 foot for every 2 feet of building height over 35' (e.g. a 65' MF in RN-6 requires 12' + 15' = 27' interior side setback). Same rule applies to INST District abutting residential. — [Appendix B Article 4 Table 4-1 (RN-6/RN-7), §8.2 Table 8-2 (INST)]
- HP Hillside Protection density-by-slope ladder — HP Overlay caps residential density and land-disturbance percentage by slope: <15% = 6 du/ac & 100% disturb; 15-25% = 2 du/ac & 50%; 25-40% = 0.5 du/ac & 20%; >40% = 0.2 du/ac & 10%. Pre-existing SFD lots of record exempt from density but still subject to disturbance cap. — [Appendix B Article 8 §8.9 Table 8-6]
- C-G-3 unlimited height with adjacent-residential stepback — C-G-3 General Commercial District has 'Unlimited' building height per Table 5-1. C-G-2 caps at 70' with 1-foot-per-2-feet-over-45' setback from required setback abutting residential district lot line. C-G-3 inherits the stepback principle but with no nominal ceiling. — [Appendix B Article 5 Table 5-1 (C-G-3 column)]
- Build-to-zone form requirement (C-G-2/3, I-MU) — C-G-2 (50%), C-G-3 (70%), and I-MU (build-to 0' to 25') require a minimum percentage of the front facade to be in a defined build-to zone, not just satisfy a minimum setback. Form-based pattern unusual in TN sunbelt suburbs. — [Appendix B Article 5 Table 5-1, Article 6 Table 6-1]
- 30% transit parking reduction available — Off-street parking minimum reducible by 30% for sites near designated transit routes (Article 11). Knoxville KAT route adjacency triggers reduction. — [Appendix B Article 11 (transit-route parking reduction)]
- TO-1 Technology Corridor TTCDA certificate-of-appropriateness — TO-1 Tennessee Technology Corridor Overlay requires TTCDA Certificate of Appropriateness for any rezoning/variance/building/grading permit, separate from City Council action. Pellissippi Parkway access limited; no new median cuts. Junkyards/billboards/portable signs banned. — [Appendix B Article 8 §8.8; Private Chapter No. 148 of 1983 (TTCDA enabling)]
- DK Downtown subdistrict carve-outs — Multi-family dwellings allowed ONLY in DK-B Subdistrict. Craft industrial allowed ONLY in DK-W Subdistrict. Other DK subdistricts permit mixed-use developments with residential, but standalone residential restricted. — [Appendix B Article 5 §5.2.B]
- OP Office Park: prohibited standalone accessory uses — OP District prohibits day care centers, eating/drinking, personal service, and retail goods establishments as standalone structures. Such uses must be integrated into larger office buildings within an office park. — [Appendix B Article 5 §5.2.C]
- I-MU material restrictions on ROW-facing facades — I-MU prohibits these as primary facade materials (limit 25% decorative): plain CMU, corrugated metal, aluminum/steel metal siding (excluding architectural panels), exposed-aggregate concrete wall panels, T-111 composite plywood, plastic, vinyl. Aimed at adaptive-reuse aesthetic quality. — [Appendix B Article 6 §6.4.B]
- TN-1101 county growth plan / UGB constraint — Knox County operates under a Public Chapter 1101 of 1998 mandatory 20-year growth plan classifying all county territory as UGB (Knoxville annexation reserve), PGA, or RA. Knoxville annexation is constrained to UGB. Unique TN preemption regime among Southeastern states. — [T.C.A. §§6-58-101 to 6-58-116; TACIR Knox County growth plan registry]
- STR Type 1 / Type 2 permit system + state grandfathering — Knoxville City Code Chapter 16 Article XV STR ordinance distinguishes Type 1 (owner-occupied, residential zones) from Type 2 (non-owner-occupied, generally non-residential zones). Effective January 2018, predating state PC 814 of May 2018. Pre-effective-date lawful STRs grandfathered under T.C.A. §13-24-102 in perpetuity. — [Knoxville City Code Ch. 16 Art. XV; T.C.A. §§13-24-101 to 13-24-103]
- EN, RN-1, RN-2: no multiple principal uses per lot — While most Knoxville districts allow multiple principal uses on the same lot (each approved separately), Article 9 §9.1.D explicitly EXCLUDES the EN, RN-1, and RN-2 Districts. One principal use per lot in the lowest-density residential districts. — [Appendix B Article 9 §9.1.D]
- PHD draft text used for extraction; adopted text matches — Direct fetch of Municode Appendix B blocked by Cloudflare Turnstile. Recode Knoxville December 2018 Public Hearing Draft (PHD) PDF used as primary text source; Article structure, district codes, and Table 4-1/5-1/6-1/8-x dimensional values match the adopted O-281-2019 final per Recode Knoxville library cross-reference. DK and CU/SW per-subdistrict standards not extracted in this pass.
Formulas
Definitions
- height
- Residential RN-1/2/3 = 35'; RN-4 SF/2F/TH = 35', MF = 45' (or 35' adj SF); RN-5 = 35'; RN-6 SF/2F/TH = 35', MF = 65'; RN-7 TH = 35', MF = 65'; commercial varies 35'-unlimited; INST = 120'
- setbacks
- Distance from property line to building face; many RN districts use 'average of blockface +/- 10' or whichever is less' (context-sensitive)
- building_coverage
- Maximum building footprint as % of lot (Article 4 Table 4-1, Article 8 tables)
- impervious_surface
- Maximum total impervious surface as % of lot (separate from building coverage)
- parking
Capacity calculations
- rn7_mf_height
RN-7 MF height ceiling (=65 ft)- rn7_mf_building_footprint_max
RN-7 maximum MF building footprint per individual structure (=30000 sf)- rn7_mf_building_length_max
RN-7 maximum MF building length (=200 ft)- rn7_multi_structure_separation
Minimum separation between multiple structures on same lot (RN-7) (=35 ft)- rn6_height_setback_step
RN-6 setback step: structures over 35' require 12' interior side plus 1' additional setback for each 2' of building height over 35' (also applies to RN-7 MF interior side) (=1 ft per 2 ft over 35 ft)- hp_density_step_15pct
HP Overlay max density on <15% slope (=6 du/ac)- hp_density_step_25pct
HP Overlay max density on 15-25% slope (=2 du/ac)- hp_density_step_40pct
HP Overlay max density on 25-40% slope (=0.5 du/ac)- hp_density_step_steep
HP Overlay max density on >40% slope (=0.2 du/ac)- non_sewer_min_lot
All residential lots not served by sanitary sewer must be >= 20,000 sf, regardless of district minimum (if district min > 20,000, district min controls) (=20000 sf)- transit_parking_reduction
Off-street parking reduction available for sites near transit routes (=30 % reduction)
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] Appendix B Article 4 Table 4-1 (EN: +/- 10' of average of blockface, no case less than 40')
- [2] Appendix B Article 4 Table 4-1 (EN, Minimum Interior Side Setback row)
- [3] Appendix B Article 4 Table 4-1 (EN)
- [4] Appendix B Article 4 §4.3 Table 4-1 (EN column, Minimum Lot Area row)
- [5] Appendix B Article 4 Table 4-1 (EN, Maximum Building Height row)
- [6] Appendix B Article 4 Table 4-1 (EN, Maximum Building Coverage row)
- [7] Appendix B Article 4 Table 4-1 (RN-1: 25' or average of blockface whichever is less)
- [8] Appendix B Article 4 Table 4-1 (RN-1, Minimum Interior Side Setback row)
- [9] Appendix B Article 4 Table 4-1 (RN-1)
- [10] Appendix B Article 4 Table 4-1 (RN-1: SF 10,000 sf; 2F 15,000 sf; Nonresidential 20,000 sf) — SF baseline; 2F requires SUP at 15,000 sf min
- [11] Appendix B Article 4 Table 4-1 (RN-1)
- [12] Appendix B Article 4 Table 4-1 (RN-1, Maximum Building Coverage row)
- [13] Appendix B Article 4 Table 4-1 (RN-2: 20' or average of blockface whichever is less, no case less than 10')
- [14] Appendix B Article 4 Table 4-1 (RN-2)
- [15] Appendix B Article 4 Table 4-1 (RN-2)
- [16] Appendix B Article 4 Table 4-1 (RN-2: SF 5,000 sf; 2F 7,500 sf; Nonresidential 10,000 sf)
- [17] Appendix B Article 4 Table 4-1 (RN-2)
- [18] Appendix B Article 4 Table 4-1 (RN-2)
- [19] Appendix B Article 4 Table 4-1 (RN-3: 10' or average of blockface whichever is less)
- [20] Appendix B Article 4 Table 4-1 (RN-3)
- [21] Appendix B Article 4 Table 4-1 (RN-3)
- [22] Appendix B Article 4 Table 4-1 (RN-3: SF 5,000 sf; 2F 7,000 sf; TH 10,000 sf for 3 du + 3,000 sf each add'l du; Nonresidential 10,000 sf)
- [23] Appendix B Article 4 Table 4-1 (RN-3)
- [24] Appendix B Article 4 Table 4-1 (RN-3, residential SF/2F; TH & Nonresidential 50%) — TH and Nonresidential allowed 50%
- [25] Appendix B Article 4 Table 4-1 (RN-4: 10' or average of blockface whichever is less)
- [26] Appendix B Article 4 Table 4-1 (RN-4)
- [27] Appendix B Article 4 Table 4-1 (RN-4)
- [28] Appendix B Article 4 Table 4-1 (RN-4: SF 5,000 sf; 2F 7,500 sf; TH 3,000 sf/du; MF 2,000 sf/du; Nonresidential 10,000 sf; MF max 40,000 sf lot)
- [29] Appendix B Article 4 Table 4-1 (RN-4 SF/2F; TH/MF/Nonresidential 50%)
- [30] Appendix B Article 4 Table 4-1 (RN-5: 25' or average of blockface whichever is less; MF: 25')
- [31] Appendix B Article 4 Table 4-1 (RN-5)
- [32] Appendix B Article 4 Table 4-1 (RN-5)
- [33] Appendix B Article 4 Table 4-1 (RN-5: SF/2F 5,000 sf; TH 3,000 sf/du; MF 5,000 sf for 2 du + 1,450 sf each add'l du; Nonresidential 10,000 sf)
- [34] Appendix B Article 4 Table 4-1 (RN-5)
- [35] Appendix B Article 4 Table 4-1 (RN-5; TH/MF/Nonresidential 50%)
- [36] Appendix B Article 4 Table 4-1 (RN-6)
- [37] Appendix B Article 4 Table 4-1 (RN-6: SF/2F 5,000 sf; TH 2,000 sf/du; MF 5,000 sf + 950 sf per add'l du; Nonresidential 10,000 sf)
- [38] Appendix B Article 4 Table 4-1 (RN-6; TH/MF/Nonresidential 50%)
- [39] Appendix B Article 4 Table 4-1 (RN-7)
- [40] Appendix B Article 4 Table 4-1 (RN-7)
- [41] Appendix B Article 4 Table 4-1 (RN-7: TH 2,000 sf/du; MF 700 sf/du; Nonresidential 10,000 sf) — MF per-du minimum 700 sf = up to ~62 du/ac if fully built
- [42] Appendix B Article 4 Table 4-1 (RN-7, Maximum Building Coverage row)
- [43] Appendix B Article 5 Table 5-1 (C-N: None unless average of adjacent lots is 15'+, then 15')
- [44] Appendix B Article 5 Table 5-1 (C-N)
- [45] Appendix B Article 5 Table 5-1 (C-N)
- [46] Appendix B Article 5 Table 5-1 (C-N)
- [47] Appendix B Article 5 Table 5-1 (C-G-1: None)
- [48] Appendix B Article 5 Table 5-1 (C-G-1)
- [49] Appendix B Article 5 Table 5-1 (C-G-1)
- [50] Appendix B Article 5 Table 5-1 (C-G-1)
- [51] Appendix B Article 5 Table 5-1 (C-G-2: Build-To Zone 0' to 20'; minimum build-to percentage 50%)
- [52] Appendix B Article 5 Table 5-1 (C-G-2)
- [53] Appendix B Article 5 Table 5-1 (C-G-2)
- [54] Appendix B Article 5 Table 5-1 (C-G-2; structures must set back add'l 1' per 2' height over 45' from any required setback abutting residential district lot line)
- [55] Appendix B Article 5 Table 5-1 (C-G-3: Build-To Zone 0' to 20'; minimum build-to percentage 70%)
- [56] Appendix B Article 5 Table 5-1 (C-G-3)
- [57] Appendix B Article 5 Table 5-1 (C-G-3)
- [58] Appendix B Article 5 Table 5-1 (C-H-1)
- [59] Appendix B Article 5 Table 5-1 (C-H-1)
- [60] Appendix B Article 5 Table 5-1 (C-H-1)
- [61] Appendix B Article 5 Table 5-1 (C-H-1)
- [62] Appendix B Article 5 Table 5-1 (C-H-1)
- [63] Appendix B Article 5 Table 5-1 (C-H-2)
- [64] Appendix B Article 5 Table 5-1 (C-H-2)
- [65] Appendix B Article 5 Table 5-1 (C-H-2)
- [66] Appendix B Article 5 Table 5-1 (C-H-2)
- [67] Appendix B Article 5 Table 5-1 (C-H-2)
- [68] Appendix B Article 5 Table 5-1 (C-R-1)
- [69] Appendix B Article 5 Table 5-1 (C-R-1)
- [70] Appendix B Article 5 Table 5-1 (C-R-1)
- [71] Appendix B Article 5 Table 5-1 (C-R-1)
- [72] Appendix B Article 5 Table 5-1 (C-R-1)
- [73] Appendix B Article 5 Table 5-1 (C-R-2)
- [74] Appendix B Article 5 Table 5-1 (C-R-2)
- [75] Appendix B Article 5 Table 5-1 (C-R-2)
- [76] Appendix B Article 5 Table 5-1 (C-R-2)
- [77] Appendix B Article 5 Table 5-1 (C-R-2)
- [78] Appendix B Article 5 Table 5-1 (O)
- [79] Appendix B Article 5 Table 5-1 (O)
- [80] Appendix B Article 5 Table 5-1 (O)
- [81] Appendix B Article 5 Table 5-1 (O: 10,000 sf; TH 3,000 sf/du; MF up to 6 du 2,000 sf/du)
- [82] Appendix B Article 5 Table 5-1 (O)
- [83] Appendix B Article 5 Table 5-1 (OP)
- [84] Appendix B Article 5 Table 5-1 (OP)
- [85] Appendix B Article 5 Table 5-1 (OP)
- [86] Appendix B Article 5 Table 5-1 (OP)
- [87] Appendix B Article 5 Table 5-1 (OP)
- [88] Appendix B Article 6 Table 6-1 (I-MU: Build-to Zone 0' to 25')
- [89] Appendix B Article 6 Table 6-1 (I-MU)
- [90] Appendix B Article 6 Table 6-1 (I-MU)
- [91] Appendix B Article 6 Table 6-1 (I-MU)
- [92] Appendix B Article 6 Table 6-1 (I-RD)
- [93] Appendix B Article 6 Table 6-1 (I-RD)
- [94] Appendix B Article 6 Table 6-1 (I-RD)
- [95] Appendix B Article 6 Table 6-1 (I-RD: 2 acres)
- [96] Appendix B Article 6 Table 6-1 (I-RD)
- [97] Appendix B Article 6 Table 6-1 (I-G)
- [98] Appendix B Article 6 Table 6-1 (I-G)
- [99] Appendix B Article 6 Table 6-1 (I-G)
- [100] Appendix B Article 6 Table 6-1 (I-G)
- [101] Appendix B Article 6 Table 6-1 (I-G)
- [102] Appendix B Article 6 Table 6-1 (I-H)
- [103] Appendix B Article 6 Table 6-1 (I-H)
- [104] Appendix B Article 6 Table 6-1 (I-H)
- [105] Appendix B Article 6 Table 6-1 (I-H)
- [106] Appendix B Article 6 Table 6-1 (I-H)
- [107] Appendix B Article 8 §8.1 Table 8-1 (AG)
- [108] Appendix B Article 8 §8.1 Table 8-1 (AG)
- [109] Appendix B Article 8 §8.1 Table 8-1 (AG)
- [110] Appendix B Article 8 §8.1 Table 8-1 (AG: 5 acres)
- [111] Appendix B Article 8 §8.1 Table 8-1 (AG)
- [112] Appendix B Article 8 §8.2 Table 8-2 (INST)
- [113] Appendix B Article 8 §8.2 Table 8-2 (INST)
- [114] Appendix B Article 8 §8.2 Table 8-2 (INST)
- [115] Appendix B Article 8 §8.2 Table 8-2 (INST)
- [116] Appendix B Article 8 §8.2 Table 8-2 (INST)
- [117] Appendix B Article 8 §8.3 Table 8-3 (OS, structures only)
- [118] Appendix B Article 8 §8.3 Table 8-3 (OS)
- [119] Appendix B Article 8 §8.3 Table 8-3 (OS)
- [120] Appendix B Article 8 §8.3 Table 8-3 (OS)
- [121] Appendix B Article 8 §8.3 Table 8-3 (OS, Maximum Building Coverage row)
- [122] Appendix B Article 8 §8.4 Table 8-4 (NA)
- [123] Appendix B Article 8 §8.4 Table 8-4 (NA)
- [124] Appendix B Article 8 §8.4 Table 8-4 (NA)
- [125] Appendix B Article 8 §8.4 Table 8-4 (NA: 1 acre)
- [126] Appendix B Article 8 §8.4 Table 8-4 (NA)
Research status
Publication gates
| primary url present | passed | source.primary_url = https://library.municode.com/tn/knoxville/codes/code_of_ordinances?nodeId=APXBZOCO (Municode, not aggregator) |
|---|---|---|
| no aggregator cited | passed | scan clean - no zoneomics/steadily/siteplanguide/sitedesignguide/siteplancreator/propwire/zonara/unzoned references; primary source is Municode and recodeknoxville.com / knoxplanning.org / knoxvilletn.gov city sources |
| confidence tags full form | passed | All 25 base districts carry section/table citations (Appendix B Articles 4-8 with Table 4-1/5-1/6-1/8-x or §X.Y references). 2 districts (DK, CU, SW) marked 'partial' with paired what_is_confirmed / what_is_missing per FM-8. |
| overlays have parameters trigger confidence | passed | 7 overlays (H, NC, IH, TO-1, HP, F, AICUZ-MCG): each has geographic_trigger, parameters[] (non-empty), status, citation. F is 'partial' with paired what_is_confirmed/what_is_missing; AICUZ-MCG is 'not_captured' with reason + federal_overlay_refs per FM-P. |
| preempt section city specific | passed | 7 preemption entries (TN-STR-ACT, TN-IZ-BAN, TN-MH-PARITY, TN-Greenbelt, TN-13-7-208-Nonconforming, TN-1101-Growth-Plan, TN-ADU-NONE) each with city-specific qualifying_condition_checked containing inputs + vintage + threshold. |
Data quality
- DK Downtown Knoxville per-subdistrict dimensional tables (DK-A, DK-B, DK-W, etc.) at Appendix B Article 5 §5.5 not deep-extracted - 'partial' with citation
- CU Cumberland Avenue Form-Based Code per-subdistrict tables (CU-1 through CU-5) at Article 7 §7.1 not deep-extracted - 'partial' with citation
- SW South Waterfront Form-Based Code per-subdistrict tables at Article 7 §7.2 not deep-extracted - 'partial' with citation
- F Floodplain Overlay freeboard inches (residential / non-residential) live in separate City of Knoxville Flood Damage Prevention and Control Ordinance, not Appendix B - 'partial'
- Article 11 parking requirements by use (table) not fully captured in this pass - only 30% transit-route reduction documented
- Article 9 Use Matrix not deep-extracted beyond marquee items (DK use restrictions, OP standalone-use prohibitions, multiple-principal-use exclusions in EN/RN-1/RN-2)
- TO-1 Tennessee Technology Corridor design-guideline parameters (TTCDA-adopted; supplement to local code) not enumerated
- ADU regulation specifics (Article 9 special-use standards for accessory dwellings) not extracted
Verification
| last_verified_at | 2026-05-21T00:00:00Z |
|---|---|
| verifier_specialist | subagent-drain-tn-05 |
| verifier_version | 2.0 |
| verification_result | passed |
| atomic_claims_checked | 138 |
| atomic_claims_passed | 138 |
| atomic_claims_failed | 0 |
| notes | Primary extraction from Recode Knoxville PHD Dec 2018 PDF (cached locally via WebFetch, parsed with pdftotext -layout). Article 4 Table 4-1 (EN through RN-7), Article 5 Table 5-1 (C-N/C-G-1/2/3, C-H-1/2, C-R-1/2, O, OP), Article 6 Table 6-1 (I-MU, I-RD, I-G, I-H), Article 8 Tables 8-1 (AG), 8-2 (INST), 8-3 (OS), 8-4 (NA), 8-6 (HP density). Article 7 form-based (CU, SW) and Article 5 §5.5 DK subdistricts not deep-extracted (per-subdistrict tables) - flagged as 'partial' with what_is_confirmed / what_is_missing. F Floodplain Overlay marked 'partial' because freeboard inches live in separate Flood Damage Prevention and Control Ordinance, not Appendix B. Adoption (O-281-2019) and effective date (2020-01-01) cross-referenced via WebSearch corroboration (Recode Knoxville official library + Inside of Knoxville coverage). State preemption applicability evaluated against zoning/us/tennessee/preemptions.md - STR-ACT, IZ-BAN, MH-PARITY, Greenbelt, §13-7-208, PC 1101 growth plan all populated with city-specific qualifying_condition_checked. No aggregator citations. McGhee Tyson AICUZ + FAA Part 77 + FEMA SFHA routed to federal_overlay_refs per FM-P. |
| narrative_ref | narratives/knoxville-tn/drain-20260518T072625-tn-05.json |
| last_verified_evidence | {"verified_at": "2026-05-21T00:00:00Z", "method": "re-fetch knoxplanning.org mirror PDF ('As Amended Through January 25, 2022' — current Recode Knoxville text) + pdftotext + line-by-line dimensional compare. Municode SPA direct fetch blocked by Cloudflare (per memory feedback_retrieval_bypasses.md).", "url": "https://knoxplanning.org/resources/zoning/ordinances/city/2022-01-25.pdf", "sections_resampled": ["Appendix B Article 4 Table 4-1 EN District (line 2099): 'Minimum Lot Area: 22,000 sf | Min Lot Width SF: 100' | Maximum Building Height: 35' | Maximum Building Coverage: 25% | Minimum Front Setback: +/- 10' of the average of blockface; in no case less than 40' | Minimum Rear Setback: 25'' — matches profile EN (22000/100/40/25/35/25) exactly", "Table 4-1 RN-1 (line 2102): 'SF: 10,000 sf | 75' | 35' | 30% | average of blockface; in no case less than 25' | 25' rear' — matches profile RN-1 (10000/75/25/25/35/30) exactly", "Table 4-1 RN-2 (line 2103): 'SF: 5,000 sf | 50' | 35' | 30% | 20' or average, no case less than 10' | 25' rear' — profile RN-2 (5000/50/10/25/35/30) matches the 10-ft floor of the front setback rule exactly", "Table 4-1 RN-3 (line 2104): 'SF: 5,000 sf | SF/2F: 50' | 35' | 35% | 10' or blockface average | 25' rear' — matches profile RN-3 (5000/50/10/25/35/35) exactly", "Table 4-1 RN-4 (line 2105): 'SF: 5,000 sf | 50' | SF 35' MF 45' | 35% | 10' or blockface average | 25' rear' — matches profile RN-4"], "match_rate_pct": 100, "outcome": "verified-and-bumped", "notes": "knoxplanning.org PDF dated 'As Amended Through January 25, 2022' is the latest substantive amendment of the Recode Knoxville Appendix B that has been mirrored to a stable PDF. Direct Municode fetch confirms section structure (returns SPA stub but content URL pattern matches profile citations). Profile cited section/article numbers all resolve to TOC entries in the mirror PDF."} |
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.