Overview
| res_sf | lot-size-encoded — SF-5 = 5,000 sf min lot; SF-10 = 10,000 sf min lot; SF-20 = 20,000 sf min lot |
|---|---|
| res_mf | density-encoded — MF-18 = 18 du/ac; MF-29 = 29 du/ac; B = 75 du/ac (labeled B not MF-75 in code) |
Joint city-county code administered by Wichita-Sedgwick County Metropolitan Area Planning Commission (MAPC). Applies within the city of Wichita and unincorporated Sedgwick County. District codes are NOT the same as the v1_legacy stub (which had RS-1/RS-2/RS-3 — those are fabricated and do not appear in the UZC). Actual residential districts are RR, SF-20, SF-10, SF-5, TF-3, MF-18, MF-29, B, MH.
- Template-bleed confirmed in v1_legacy stub: districts were fabricated as RS-1/RS-2/RS-3 (do not exist in UZC); actual single-family districts are RR/SF-20/SF-10/SF-5. All dimensional values (lot_coverage=0.5, far=0.5, setback_side=25) in v1 were synthetic fills.
- UZC does not use FAR as a standard dimensional metric — all districts show null FAR. Bulk controlled by setbacks, lot area minimums, and height.
- The '0/5 ft' interior-side setback notation (commercial/office/industrial districts) means 0 ft where abutting a compatible use under a shared-wall provision, 5 ft otherwise — per footnote 1 of the Zoning Chart; see §IV for full detail.
+ 7 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RR | Rural Residential | ag | 87,120 sf[4] | 35 ft[5] | —[6] | —[7] | —[8] | —[9] | 30[1] / 20[2] / 25[3] |
| SF-20 | Single-Family 20,000 | res_sf | 20,000 sf[13] | 35 ft[14] | —[15] | —[16] | —[17] | —[18] | 25[10] / 10[11] / 25[12] |
| SF-10 | Single-Family 10,000 | res_sf | 10,000 sf[22] | 35 ft[23] | —[24] | —[25] | —[26] | —[27] | 25[19] / 10[20] / 25[21] |
| SF-5 | Single-Family 5,000 | res_sf | 5,000 sf[31] | 35 ft[32] | —[33] | —[34] | —[35] | —[36] | 25[28] / 6[29] / 20[30] |
| TF-3 | Two-Family | res_mf | [{'variant': 'single-family', 'value': 3500, 'citation': '§III-B.5, Zoning Chart'}, {'variant': 'two-family', 'value': 3000, 'citation': '§III-B.5, Zoning Chart'}, {'variant': 'multi-family', 'value': 3000, 'citation': '§III-B.5, Zoning Chart'}, {'variant': 'nonresidential', 'value': 5000, 'citation': '§III-B.5, Zoning Chart'}] sf[40] | 35 ft[41] | —[42] | —[43] | —[44] | —[45] | 25[37] / 6[38] / 20[39] |
| MF-18 | Multi-Family 18 du/ac | res_mf | [{'variant': 'single-family', 'value': 3500, 'citation': '§III-B.6, Zoning Chart'}, {'variant': 'two-family', 'value': 3000, 'citation': '§III-B.6, Zoning Chart'}, {'variant': 'multi-family', 'value': 2500, 'citation': '§III-B.6, Zoning Chart'}, {'variant': 'nonresidential', 'value': 5000, 'citation': '§III-B.6, Zoning Chart'}] sf[49] | 45 ft[50] | —[51] | —[52] | 18[53] | —[54] | 25[46] / 6[47] / 20[48] |
| MF-29 | Multi-Family 29 du/ac | res_mf | [{'variant': 'single-family', 'value': 3500, 'citation': '§III-B.7, Zoning Chart'}, {'variant': 'two-family', 'value': 3000, 'citation': '§III-B.7, Zoning Chart'}, {'variant': 'multi-family', 'value': 1500, 'citation': '§III-B.7, Zoning Chart'}, {'variant': 'nonresidential', 'value': 5000, 'citation': '§III-B.7, Zoning Chart'}] sf[58] | 45 ft[59] | —[60] | —[61] | 29[62] | —[63] | 25[55] / 6[56] / 20[57] |
| B | Multi-Family 75 du/ac | res_mf | [{'variant': 'single-family-type-a', 'value': 2500, 'citation': '§III-B.8, Zoning Chart'}, {'variant': 'single-family-type-b', 'value': 2000, 'citation': '§III-B.8, Zoning Chart'}, {'variant': 'multi-family', 'value': 580, 'citation': '§III-B.8, Zoning Chart'}, {'variant': 'nonresidential', 'value': 5000, 'citation': '§III-B.8, Zoning Chart'}] sf[67] | 55 ft[68] | —[69] | —[70] | 75[71] | —[72] | 20[64] / 5[65] / 15[66] |
| MH | Manufactured Housing | res_sf | [{'variant': 'site-in-wichita', 'value': 217800, 'note': '5 ac = 217,800 sf', 'citation': '§III-B.9, Zoning Chart'}, {'variant': 'subdivision-lots', 'value': 5000, 'citation': '§III-B.9, Zoning Chart'}, {'variant': 'nonresidential', 'value': 10000, 'citation': '§III-B.9, Zoning Chart'}] sf[76] | 35 ft[77] | —[78] | —[79] | —[80] | —[81] | 25[73] / 6[74] / 20[75] |
| NO | Neighborhood Office | off | [{'variant': 'sf-or-nonresidential', 'value': 5000, 'citation': '§III-B.10, Zoning Chart'}, {'variant': 'two-family-or-mf', 'value': 3000, 'citation': '§III-B.10, Zoning Chart'}] sf[85] | 35 ft[86] | —[87] | —[88] | —[89] | —[90] | 20[82] / 0[83] / 10[84] |
| GO | General Office | off | [{'variant': 'single-family', 'value': 2500, 'citation': '§III-B.11, Zoning Chart'}, {'variant': 'two-family', 'value': 2000, 'citation': '§III-B.11, Zoning Chart'}, {'variant': 'multi-family', 'value': 580, 'citation': '§III-B.11, Zoning Chart'}, {'variant': 'nonresidential', 'value': 5000, 'citation': '§III-B.11, Zoning Chart'}] sf[94] | 60 ft[95] | —[96] | —[97] | —[98] | —[99] | 20[91] / 0[92] / 10[93] |
| NR | Neighborhood Retail | com | [{'variant': 'sf-or-nonresidential', 'value': 5000, 'citation': '§III-B.12, Zoning Chart'}, {'variant': 'two-family', 'value': 3000, 'citation': '§III-B.12, Zoning Chart'}, {'variant': 'multi-family', 'value': 2000, 'citation': '§III-B.12, Zoning Chart'}] sf[103] | 35 ft[104] | —[105] | —[106] | —[107] | —[108] | 20[100] / 0[101] / 10[102] |
| LC | Limited Commercial | com | [{'variant': 'single-family', 'value': 2500, 'citation': '§III-B.14, Zoning Chart'}, {'variant': 'two-family', 'value': 2000, 'citation': '§III-B.14, Zoning Chart'}, {'variant': 'multi-family', 'value': 580, 'citation': '§III-B.14, Zoning Chart'}, {'variant': 'nonresidential', 'note': 'No minimum', 'value': 0, 'citation': '§III-B.14, Zoning Chart'}] sf[112] | 80 ft[113] | —[114] | —[115] | —[116] | —[117] | 20[109] / 0[110] / 10[111] |
| OW | Office Warehouse | ind | 5,000 sf[121] | 45 ft[122] | —[123] | —[124] | —[125] | —[126] | 20[118] / 0[119] / 10[120] |
| GC | General Commercial | com | [{'variant': 'single-family', 'value': 2500, 'citation': '§III-B.16, Zoning Chart'}, {'variant': 'two-family', 'value': 2000, 'citation': '§III-B.16, Zoning Chart'}, {'variant': 'multi-family', 'value': 580, 'citation': '§III-B.16, Zoning Chart'}, {'variant': 'nonresidential', 'note': 'No minimum', 'value': 0, 'citation': '§III-B.16, Zoning Chart'}] sf[130] | 80 ft[131] | —[132] | —[133] | —[134] | —[135] | 20[127] / 0[128] / 10[129] |
| IP-A | Industrial Park - Airport | ind | —[139] | 60 ft[140] | —[141] | —[142] | —[143] | —[144] | 50[136] / 15[137] / 10[138] |
| IP | Industrial Park | ind | —[148] | 60 ft[149] | —[150] | —[151] | —[152] | —[153] | 50[145] / 15[146] / 10[147] |
| CBD | Central Business District | cbd | [{'variant': 'single-family', 'value': 2500, 'citation': '§III-B.19, Zoning Chart'}, {'variant': 'two-family', 'value': 2000, 'citation': '§III-B.19, Zoning Chart'}, {'variant': 'multi-family', 'value': 250, 'citation': '§III-B.19, Zoning Chart'}, {'variant': 'nonresidential', 'note': 'No minimum', 'value': 0, 'citation': '§III-B.19, Zoning Chart'}] sf[157] | -1 ft[158] | —[159] | —[160] | -1[161] | —[162] | 0[154] / 0[155] / 0[156] |
| LI | Limited Industrial | ind | —[166] | 80 ft[167] | —[168] | —[169] | —[170] | —[171] | 20[163] / 0[164] / —[165] |
| GI | General Industrial | ind | —[175] | 80 ft[176] | —[177] | —[178] | —[179] | —[180] | 20[172] / 0[173] / —[174] |
Confidence: confirmed partial under review not found
Overlays
Applies to locally-designated historic districts and properties; also applies to State and National Historic Register environs per K.S.A. 75-2724 (500-ft review zone). Source: Zoning Chart Special Purpose section
| requirement | Design review required for alterations, demolition, and new construction within designated area |
|---|---|
| administration | Wichita-Sedgwick County Metropolitan Area Planning Commission; landmarks board review |
| citation | §III-C.1, Zoning Chart |
Applies to parcels within the accident potential zones (APZ) and noise contours (≥65 dB DNL) of McConnell Air Force Base, Wichita. Sub-districts A-O I, A-O II N, A-O II S, A-O III N, A-O III S based on proximity to flight paths. Source: Zoning Chart; McConnell AFB AICUZ study
| prohibited_uses_A-O_II | Mobile Food Unit in City prohibited in A-O II N and A-O II S (§III-C.5.g.(2) per Ord. 50-541); residential uses restricted or prohibited depending on sub-zone |
|---|---|
| prohibited_uses_A-O_III | Mobile Food Unit in City prohibited in A-O III N and A-O III S (§III-C.5.g.(3) per Ord. 50-541) |
| height_restriction | Height limited by AICUZ imaginary surfaces and Part 77; airport zoning permit required for structures in airport hazard areas per Airport Hazard Zoning Code (updated Sept 2025) |
| federal_overlay_ref | DoD AICUZ McConnell AFB; K.S.A. 12-769 through 12-775 state companion |
| citation | §III-C.5, Ord. 50-541 §§7-8 |
Applies around five regulated airports: Wichita Dwight D. Eisenhower National Airport (KICT), Colonel James Jabara Airport, McConnell AFB, Beech Factory Airport, Cessna Airport. Height hazard zones A through D based on distance from airport.
| zone_a | Nearest airport — permits structures up to 25 ft without permit |
|---|---|
| zone_d | Farthest — permits structures up to 200 ft without permit |
| permit_required | Any tower or transmitting structure regardless of height; structures exceeding zone height limits |
| federal_overlay_ref | FAA 14 CFR Part 77 imaginary surfaces; FAA Advisory Circular AC 150/5300-13 RPZ standards |
| citation | K.S.A. 3-301 through 3-322; Airport Hazard Zoning Code (Sept 2025 revision) |
Applies to parcels within FEMA-mapped Special Flood Hazard Area (SFHA) — 100-year floodplain — and the regulatory floodway of the Arkansas River and its tributaries within Wichita. Wichita participates in NFIP.
| freeboard | 1 ft above Base Flood Elevation (BFE) for new residential construction in SFHA per local ordinance; commercial may differ — requires §IV verification |
|---|---|
| floodway_prohibition | No fill or development that increases BFE per 44 CFR 60.3(d) and local floodplain ordinance |
| permit_required | Local floodplain development permit required for any construction in SFHA |
| state_permit | KDAW-DWR stream obstruction permit required for works in regulatory floodway per K.S.A. 12-768 |
| citation | K.S.A. 12-766 through 12-768; local floodplain ordinance (§IV); FEMA FIRM panels for Sedgwick County |
Applies to the Old Town warehouse district in downtown Wichita. Geographically bounded overlay — see Zoning Code Supplement map.
| parking_deviation | Allows deviations from standard parking requirements in §IV-A |
|---|---|
| use_deviation | Allows some uses not otherwise permitted in underlying base district |
| design_standards | Special design standards for building materials, facades, and compatibility with existing warehouse character |
| citation | §III-C.3, Zoning Chart |
Applied by text/map amendment to specific areas where additional use restrictions or development standards are needed to ensure compatibility. Geographic trigger varies by application — set at time of rezoning.
| parameters | Use restrictions and development standards specified in the individual P-O resolution at time of designation |
|---|---|
| citation | §III-C.4, Zoning Chart |
Applies to the Delano Neighborhood area of Wichita. Geographically bounded overlay preserving the Delano district character.
| purpose | Preserve and promote the character of the Delano Neighborhood |
|---|---|
| requirements | Design review and compatibility standards for alterations and new construction |
| citation | §III-C.2, Zoning Chart |
Applies where transportation corridor preservation plans are in effect. Assures review of impact of transportation projects on adjacent neighborhood character.
| purpose | Review transportation project impacts on neighborhood character |
|---|---|
| citation | §III-C, Zoning Chart |
Applies to parcels in proximity to McConnell AFB where anti-terrorism/force protection site development regulations are required.
| purpose | Protect McConnell AFB from terrorist activities through Site Development Regulations |
|---|---|
| requirements | Minimum standoff distances and site development restrictions per DoD AT/FP standards |
| federal_overlay_ref | DoD Unified Facilities Criteria UFC 4-010-01 (AT/FP standards) |
| citation | §III-C.6, Zoning Chart |
not_found
| not_found | No local affordable housing bonus overlay found in Zoning Chart or Municode TOC search. Kansas does not have a statewide ADU/density-bonus preemption statute. Search performed on Zoning Chart PDF and wichita.gov documents page. |
|---|
State preemptions
Adopted building codes
No statewide code
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-05-26 | retrieved at | Zoning Chart PDF retrieved from https://www.wichita.gov/DocumentCenter/View/9758/Zoning-Chart-PDF |
| 2017-06-13 | amendment effective | Ordinance No. 50-541 (most recent amendment in sedgwickcounty.org index as of 2026-05-26) |
| 2009-09-25 | codification start | Ordinance No. 48-451, adopting base UZC by reference in City Code Sec. 28.04.010 |
Quirks & notes
- Template-bleed confirmed in v1_legacy stub: districts were fabricated as RS-1/RS-2/RS-3 (do not exist in UZC); actual single-family districts are RR/SF-20/SF-10/SF-5. All dimensional values (lot_coverage=0.5, far=0.5, setback_side=25) in v1 were synthetic fills.
- UZC does not use FAR as a standard dimensional metric — all districts show null FAR. Bulk controlled by setbacks, lot area minimums, and height.
- The '0/5 ft' interior-side setback notation (commercial/office/industrial districts) means 0 ft where abutting a compatible use under a shared-wall provision, 5 ft otherwise — per footnote 1 of the Zoning Chart; see §IV for full detail.
- The '6/0 ft' interior-side setback notation (SF-5, TF-3) means 6 ft standard; 0 ft for Lots of Record ≤40 ft wide existing at time of Wichita Ordinance No. 10-107 adoption (Oct 1, 1928) per §III-B.4 — confirmed via Google snippet.
- Height expressed as 'X + 1 ft increase per 1 ft additional setback' for GO (60 ft base), LC/GC (80 ft), LI/GI (80 ft), and B (55 ft) districts — scalar v field captures base height only.
- District code 'B' (Multi-Family 75 du/ac) breaks the MF-nn naming pattern used for lower density residential districts — this is the actual code designation in the UZC.
- The UZC is a joint City of Wichita / Sedgwick County code administered by MAPC. City Code Sec. 28.04.010 adopts the UZC by reference (Ordinance No. 48-451). The Municode library entry is hosted under 'wichita-sedgwick_county_unified' not under either city or county separately.
- Parking standards at §IV-A.4 (Use Regulations Schedule) not extracted in this pass — parking KPI left as not_captured across all districts. Requires dedicated §IV-A pass.
- Lot coverage standards not explicitly tabulated in Zoning Chart — the UZC controls bulk primarily through setbacks and height. Lot coverage provisions may exist in §IV Site Development Standards but were not retrieved in this pass.
- McConnell AFB AICUZ airport overlay sub-zones (A-O I, A-O II N, A-O II S, A-O III N, A-O III S) are mapped on a separate Supplement Map (wichita.gov/DocumentCenter/View/9753); the PDF is a map image only with minimal text extraction possible.
Formulas
Definitions
- height
- Vertical distance from grade to highest point of structure. Two-story cap in some SF districts per §III-B. See Zoning Chart footnote 1 for conditional height maximums.
- lot_coverage
- Not separately tabulated in Zoning Chart; FAR and setbacks effectively govern coverage. See §IV (Site Development Standards) for lot coverage provisions.
- far
- Not a standard dimensional metric in the UZC — the code uses lot area minimums, setbacks, and height to control bulk, not FAR ratios.
- du_ac
- Density control varies: MF districts use named du/ac caps encoded in the district designation (MF-18, MF-29, B=75 du/ac). SF/TF districts control density via minimum lot area per unit.
- setback_front
- Minimum distance from front property line to nearest building face; see Zoning Chart columns. Street-side setback applies to corner lots.
- setback_side
- Interior-side setback applies between interior lot lines. 0/5 ft notation: 0 ft if abutting another commercial/industrial use under shared-wall provision, 5 ft otherwise. 6/0 ft notation for residential: 6 ft standard, 0 ft for infill lots of record per §III-B.
- setback_rear
- Minimum distance from rear property line to building face; see Zoning Chart columns.
- parking
- Off-street parking governed by §IV-A.4 Use Regulations Schedule. Not captured in this profile — requires separate extraction from Sec. IV-A.
Capacity calculations
- max_footprint_sf
No FAR — governed by setbacks and height- buildable_width_ft
lot_width_ft - setback_interior_side_ft - setback_street_side_or_interior_ft- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- max_stories_approx
max_height_ft / 10
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
Municode (library.municode.com) returns HTTP 403 Cloudflare challenge on direct fetch. Dimensional data sourced from official Zoning Chart PDF at wichita.gov/DocumentCenter (unblocked). Use Regulations chart sourced from same. Ordinance amendment text sourced from sedgwickcounty.org PDF (unblocked). Wayback Machine cdx search confirmed Municode UZC is an SPA (server-rendered HTML unavailable). GIS endpoint not searched in this pass.
- [1] §III-B.1
- [2] §III-B.1
- [3] §III-B.1
- [4] §III-B.1
- [5] §III-B.1
- [6] n
- [7] n
- [8] n
- [9] n
- [10] §III-B.2
- [11] §III-B.2
- [12] §III-B.2
- [13] §III-B.2
- [14] §III-B.2
- [15] n
- [16] n
- [17] n
- [18] n
- [19] §III-B.3
- [20] §III-B.3
- [21] §III-B.3
- [22] §III-B.3
- [23] §III-B.3
- [24] n
- [25] n
- [26] n
- [27] n
- [28] §III-B.4
- [29] §III-B.4
- [30] §III-B.4
- [31] §III-B.4
- [32] §III-B.4
- [33] n
- [34] n
- [35] n
- [36] n
- [37] §III-B.5
- [38] §III-B.5
- [39] §III-B.5
- [40] §III-B.5
- [41] §III-B.5
- [42] n
- [43] n
- [44] n
- [45] n
- [46] §III-B.6
- [47] §III-B.6
- [48] §III-B.6
- [49] §III-B.6
- [50] §III-B.6
- [51] n
- [52] n
- [53] §III-B.6
- [54] n
- [55] §III-B.7
- [56] §III-B.7
- [57] §III-B.7
- [58] §III-B.7
- [59] §III-B.7
- [60] n
- [61] n
- [62] §III-B.7
- [63] n
- [64] §III-B.8
- [65] §III-B.8
- [66] §III-B.8
- [67] §III-B.8
- [68] §III-B.8
- [69] n
- [70] n
- [71] §III-B.8
- [72] n
- [73] §III-B.9
- [74] §III-B.9
- [75] §III-B.9
- [76] §III-B.9
- [77] §III-B.9
- [78] n
- [79] n
- [80] n
- [81] n
- [82] §III-B.10
- [83] §III-B.10
- [84] §III-B.10
- [85] §III-B.10
- [86] §III-B.10
- [87] n
- [88] n
- [89] n
- [90] n
- [91] §III-B.11
- [92] §III-B.11
- [93] §III-B.11
- [94] §III-B.11
- [95] §III-B.11
- [96] n
- [97] n
- [98] n
- [99] n
- [100] §III-B.12
- [101] §III-B.12
- [102] §III-B.12
- [103] §III-B.12
- [104] §III-B.12
- [105] n
- [106] n
- [107] n
- [108] n
- [109] §III-B.14
- [110] §III-B.14
- [111] §III-B.14
- [112] §III-B.14
- [113] §III-B.14
- [114] n
- [115] n
- [116] n
- [117] n
- [118] §III-B.15
- [119] §III-B.15
- [120] §III-B.15
- [121] §III-B.15
- [122] §III-B.15
- [123] n
- [124] n
- [125] n
- [126] n
- [127] §III-B.16
- [128] §III-B.16
- [129] §III-B.16
- [130] §III-B.16
- [131] §III-B.16
- [132] n
- [133] n
- [134] n
- [135] n
- [136] §III-B.22
- [137] §III-B.22
- [138] §III-B.22
- [139] §III-B.22
- [140] §III-B.22
- [141] n
- [142] n
- [143] n
- [144] n
- [145] §III-B.23
- [146] §III-B.23
- [147] §III-B.23
- [148] §III-B.23
- [149] §III-B.23
- [150] n
- [151] n
- [152] n
- [153] n
- [154] §III-B.19
- [155] §III-B.19
- [156] §III-B.19
- [157] §III-B.19
- [158] §III-B.19
- [159] n
- [160] n
- [161] §III-B.19
- [162] n
- [163] §III-B.20
- [164] §III-B.20
- [165] §III-B.20
- [166] §III-B.20
- [167] §III-B.20
- [168] n
- [169] n
- [170] n
- [171] n
- [172] §III-B.21
- [173] §III-B.21
- [174] §III-B.21
- [175] §III-B.21
- [176] §III-B.21
- [177] n
- [178] n
- [179] n
- [180] n
Research status
Publication gates
| primary url present | passed | source.primary_url = https://library.municode.com/ks/wichita-sedgwick_county_unified/codes/unified_zoning_code — https, not an aggregator domain |
|---|---|---|
| no aggregator cited | passed | scan clean — no Zoneomics, Steadily, SitePlanGuide, Propwire, Zonara, or Unzoned references in record |
| confidence tags full form | passed | 87 confirmed fields carry §-citations (e.g. c§III-B.1 through c§III-B.21, c§III-C.1 through c§III-C.6, c§IV). All confirmed KPI values carry district-section citations. No bare 'confirmed' without citation. |
| overlays have parameters trigger confidence | passed | 9 overlays documented: H-O, A-O, AHZ, FP, OT-O, P-O, D-O, CP-O, AFBP-O. Each has non-empty params, geographic_trigger (or not_found with search_performed for AH overlay), status, and §-citation. AH overlay explicitly documented as not_found with search evidence. |
| preempt section city specific | passed | 6 laws evaluated with city-specific qualifying_condition_checked: K.S.A. 12-758(h) [pop 397,532 / first-class city], K.S.A. 12-766 [NFIP participation / Arkansas River SFHA], K.S.A. 12-769 [McConnell AFB in Sedgwick County / A-O districts confirmed], K.S.A. 3-301 [5 airports confirmed at wichita.gov/1582], K.S.A. 75-2715 [H-O overlay / KHS environs], K.S.A. 12-741 [first-class city / Ord. 48-451 enabling clause]. Kansas is not in the Gate 5 mandatory list (CA/TX/FL/OR/WA/CO/MN/MT/UT/AZ/NJ/CT) but preemption entries are provided and city-specific. |
Data quality
- Parking standards (§IV-A.4) not extracted — requires dedicated §IV-A pass
- Lot coverage provisions (§IV Site Development Standards) not extracted
- FAR not a UZC metric — null for all districts (confirmed, not a gap)
- Airport overlay sub-zone boundaries (A-O I through A-O III S) are map-only — geographic trigger documented but boundaries not in text form
- Municode live version (library.municode.com) 403-blocked by Cloudflare; could not confirm any post-2017 amendments incorporated since Ord. 50-541
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.