Overview
Union City uses a mixed naming convention. Single-family residential districts encode minimum lot size (RS 6000, RS 4500, R 5000). Multi-family residential districts encode minimum site area per unit (RM 3500, RM 2500, RM 1500). Commercial districts use letter-code abbreviations (CPA, CN, CC, CVR, CS, CMU). Industrial districts use letter-code (MG, ML, MS). Station East districts are named (SEMU-R, SEE). Hillside (H) combining district applies as an overlay.
- GIS endpoint corrected: the issue-provided endpoint (maps.hayward-ca.gov/arcgis/rest/services/OpenData/COH_Zoning/FeatureServer/0) serves the City of Hayward — NOT Union City. Correct Union City CA zoning endpoint: https://services7.arcgis.com/T3LbxamSmhpjBppB/arcgis/rest/services/ZoningUpdate_2024_view/FeatureServer (org BMI_NPGS_UnionCity_Admin, 892 features, centroid at lat 37.604 lon -122.082, within 1.5° of city centroid 37.603/-122.019). Three GIS gates all passed.
- ecode360 at ecode360.com/UN5025 returns HTTP 403 to scripted access. Residential and commercial dimensional standards sourced from city-published PDFs on unioncityca.gov. Industrial (MG, ML, MS) and CMU dimensional standards not_captured — no accessible PDF equivalent found for those chapters.
- RS naming is lot-size-encoded (RS 6000 = 6,000 sf min lot; RS 4500 = 4,500 sf min lot). Multi-family RM naming encodes minimum site area per unit (RM 3500 = 3,500 sf/unit). R 5000 (no 'S') is a separate chapter (§18.88) with slightly different standards including one-story 60% lot coverage option.
+ 3 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RS 6000 | Single Family Residential — 6,000 sf Minimum Lot | res_sf | 6,000 sf[1] | 30 ft[2] | 50[3] | —[4] | —[5] | —[6] | — / — / — |
| RS 4500 | Single Family Residential — 4,500 sf Minimum Lot | res_sf | 4,500 sf[7] | 30 ft[8] | 50[9] | —[10] | —[11] | —[12] | — / — / — |
| R 5000 | Single Family Residential — 5,000 sf Minimum Lot (R-5000) | res_sf | 5,000 sf[13] | 30 ft[14] | —[15] | —[16] | —[17] | —[18] | — / — / — |
| RM 3500 | Multi-Family Residential — 3,500 sf Per Unit | res_mf | 7,000 sf[19] | 30 ft[20] | 40[21] | —[22] | —[23] | —[24] | — / — / — |
| RM 2500 | Multi-Family Residential — 2,500 sf Per Unit | res_mf | 6,000 sf[25] | 30 ft[26] | 40[27] | —[28] | —[29] | —[30] | — / — / — |
| RM 1500 | Multi-Family Residential — 1,500 sf Per Unit | res_mf | 6,000 sf[31] | 75 ft[32] | 40[33] | —[34] | —[35] | —[36] | — / — / — |
| CPA | Professional and Administrative Commercial | com | 5,000 sf[37] | 100 ft[38] | 50[39] | —[40] | — | —[41] | — / — / — |
| CN | Neighborhood Commercial | com | 5,000 sf[42] | 30 ft[43] | —[44] | —[45] | — | —[46] | — / — / — |
| CC | Community Commercial | com | 5,000 sf[47] | 100 ft[48] | —[49] | —[50] | — | —[51] | — / — / — |
| CVR | Visitor-Serving Commercial | com | 5,000 sf[52] | 100 ft[53] | —[54] | —[55] | — | —[56] | — / — / — |
| CS | Service Commercial | com | 5,000 sf[57] | 40 ft[58] | —[59] | —[60] | — | —[61] | — / — / — |
| CMU | Corridor Mixed Use Commercial | spec | —[62] | —[63] | —[64] | —[65] | —[66] | —[67] | — / — / — |
| SEMU-R | Station East Mixed Use Residential | spec | 3,500 sf[68] | 100 ft[69] | —[70] | —[71] | —[72] | —[73] | — / — / — |
| SEE | Station East Employment | spec | —[74] | 100 ft[75] | —[76] | —[77] | —[78] | —[79] | — / — / — |
| MG | General Industrial | ind | —[80] | —[81] | —[82] | —[83] | — | —[84] | — / — / — |
| ML | Light Industrial | ind | —[85] | —[86] | —[87] | —[88] | — | —[89] | — / — / — |
| MS | Special Industrial | ind | —[90] | —[91] | —[92] | —[93] | — | —[94] | — / — / — |
| OS | Open Space | spec | —[95] | —[96] | —[97] | —[98] | — | —[99] | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Properties within the mapped Hillside area per the Official Zoning Map (4 polygon features covering hillside terrain in east Union City, centroid near lat 37.592, lon -122.002).
| geographic_applicability | Applied as a combining district overlay to base residential zones in the Hillside area east of the city core. |
|---|---|
| supplemental_standards | Additional grading, slope, and development standards apply per Title 18 Hillside Combining District chapter. Precise standards not_captured — ecode360 source blocked to scripted access. |
| gis_confirmed | Verified present in Overlay_and_Combining_Districts_View FeatureServer layer (4 polygons, OBJECTID 1-4). |
Properties individually designated as historic landmarks or located within a locally designated historic district per Planning Commission approval under Chapter 18.106.
| designation_criteria | Planning Commission may designate structures, improvements, natural features, objects, or areas that exemplify special elements of cultural, social, economic, political, aesthetic, architectural, or natural history. |
|---|---|
| review_required | Alterations to designated properties require review under Chapter 18.106 landmark and historic preservation procedures. |
| interaction | Applies as an overlay to base zoning districts; base dimensional standards remain but exterior alterations are subject to historic review. |
Properties within FEMA-mapped Special Flood Hazard Areas (SFHA) as shown on the Flood Insurance Rate Map (FIRM) adopted by Union City under Chapter 18.98.
| fema_adoption | City has adopted FEMA FIRM per Chapter 18.98 statutory authorization. |
|---|---|
| purpose | Flood hazard reduction through limitations on development, fill, and alteration of watercourses in flood-prone areas. |
| freeboard_requirements | General provisions and flood hazard reduction standards apply per §18.98; precise freeboard above BFE not_captured (source blocked). |
| administration | Floodplain Administrator designated per Chapter 18.98 to administer FEMA NFIP requirements. |
Properties within the Station District Specific Plan area surrounding the Union City BART Station, including SEMU-R and SEE base zoning districts.
| bart_station | Union City BART Station (heavy rail) — qualifies as major transit stop under GC §21064.3. |
|---|---|
| districts_within | SEMU-R (Station East Mixed Use Residential) and SEE (Station East Employment) base districts implement TOD standards with minimum density floors and ground-floor commercial requirements. |
| min_density | SEMU-R: minimum 25 du/ac, average 50 du/ac, maximum 100 du/ac (§18.37.020). |
| parking_standard | AB 2097 applies within 0.5 miles of Union City BART Station — local parking minimums prohibited for qualifying projects per GC §65863.2. |
Any qualifying housing project with affordable units as a percentage of base project units, anywhere in Union City.
| bonus_tiers | Up to 50% base density bonus (additional AB 1287 stacking not confirmed from primary source); affordability tiers per GC §65915. |
|---|---|
| incentives | 1 to 4 development concessions and incentives based on affordability percentage. |
| interaction | Overrides local height, setback, density, and FAR limits to the extent required to permit the density bonus units. |
State preemptions
Non-applicable laws (2)
Adopted building codes
Statewide mandatory minimum
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- GIS endpoint corrected: the issue-provided endpoint (maps.hayward-ca.gov/arcgis/rest/services/OpenData/COH_Zoning/FeatureServer/0) serves the City of Hayward — NOT Union City. Correct Union City CA zoning endpoint: https://services7.arcgis.com/T3LbxamSmhpjBppB/arcgis/rest/services/ZoningUpdate_2024_view/FeatureServer (org BMI_NPGS_UnionCity_Admin, 892 features, centroid at lat 37.604 lon -122.082, within 1.5° of city centroid 37.603/-122.019). Three GIS gates all passed.
- ecode360 at ecode360.com/UN5025 returns HTTP 403 to scripted access. Residential and commercial dimensional standards sourced from city-published PDFs on unioncityca.gov. Industrial (MG, ML, MS) and CMU dimensional standards not_captured — no accessible PDF equivalent found for those chapters.
- RS naming is lot-size-encoded (RS 6000 = 6,000 sf min lot; RS 4500 = 4,500 sf min lot). Multi-family RM naming encodes minimum site area per unit (RM 3500 = 3,500 sf/unit). R 5000 (no 'S') is a separate chapter (§18.88) with slightly different standards including one-story 60% lot coverage option.
- Station East districts (SEMU-R §18.37 and SEE §18.36) share FAR range 0.40–3.0 and 100 ft max height. SEMU-R has a minimum density floor of 25 du/ac and average of 50 du/ac — density cannot go lower than 25 du/ac. Co-working space required in buildings ≥250 units.
- Overlay_and_Combining_Districts_View FeatureServer confirmed a Hillside (H) combining district with 4 polygon features in east Union City. Precise dimensional modifications under the Hillside chapter not_captured due to ecode360 access block.
- The GIS ZoningUpdate_2024_view dataset was last updated August 2024 per ArcGIS item metadata, suggesting it reflects 2024 zoning amendments.
Formulas
Definitions
- height
- Vertical distance from average contact ground level to the highest point of the roof structure per Title 18 general definitions.
- density
- Dwelling units per net acre of site area.
- setback
- Minimum horizontal distance from property line to nearest point of principal structure.
- lot_coverage
- Maximum buildable footprint as a percentage of total lot area.
- far
- Total gross floor area divided by net lot area.
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §18.20 Residential Stds PDF
- [2] §18.20 Residential Stds PDF
- [3] §18.20 Residential Stds PDF
- [4] §18.20 not_captured — not shown in residential standards PDF
- [5] §18.20 not explicitly stated — single dwelling unit per lot max
- [6] §18.50 not_captured — not in residential standards PDF
- [7] §18.20 Residential Stds PDF
- [8] §18.20 Residential Stds PDF
- [9] §18.20 Residential Stds PDF
- [10] §18.20 not_captured
- [11] §18.20 not explicitly stated
- [12] §18.50 not_captured
- [13] §18.88 Residential Stds PDF; ecode360.com/43316342
- [14] §18.88 Residential Stds PDF Note 9 (lesser of 2 stories or 30 ft)
- [15] §18.88 Residential Stds PDF Note 3
- [16] §18.88 not_captured
- [17] §18.88 not explicitly stated
- [18] §18.88 not_captured
- [19] §18.30 Residential Stds PDF
- [20] §18.30 Residential Stds PDF
- [21] §18.30 Residential Stds PDF
- [22] §18.30 not_captured
- [23] §18.30 density governed by min 3,500 sf per unit; du/ac not explicitly stated in PDF
- [24] §18.50 not_captured
- [25] §18.30 Residential Stds PDF
- [26] §18.30 Residential Stds PDF
- [27] §18.30 Residential Stds PDF
- [28] §18.30 not_captured
- [29] §18.30 density governed by min 2,500 sf per unit
- [30] §18.50 not_captured
- [31] §18.30 Residential Stds PDF
- [32] §18.30 Residential Stds PDF
- [33] §18.30 Residential Stds PDF
- [34] §18.30 not_captured
- [35] §18.30 density governed by min 1,500 sf per unit
- [36] §18.50 not_captured
- [37] §18.36 Commercial Stds PDF
- [38] §18.36 Commercial Stds PDF
- [39] §18.36 Commercial Stds PDF
- [40] §18.36 not_captured — not shown in commercial standards PDF
- [41] §18.50 not_captured
- [42] §18.36 Commercial Stds PDF
- [43] §18.36 Commercial Stds PDF
- [44] §18.36 no maximum shown in PDF
- [45] §18.36 not_captured
- [46] §18.50 not_captured
- [47] §18.36 Commercial Stds PDF
- [48] §18.36 Commercial Stds PDF
- [49] §18.36 no maximum shown
- [50] §18.36 not_captured
- [51] §18.50 not_captured
- [52] §18.36 Commercial Stds PDF
- [53] §18.36 Commercial Stds PDF
- [54] §18.36 no maximum shown
- [55] §18.36 not_captured
- [56] §18.50 not_captured
- [57] §18.36 Commercial Stds PDF
- [58] §18.36 Commercial Stds PDF
- [59] §18.36 no maximum shown
- [60] §18.36 not_captured
- [61] §18.50 not_captured
- [62] §18.35 not_captured — ecode360 blocked
- [63] §18.35 not_captured
- [64] §18.35 not_captured
- [65] §18.35 not_captured
- [66] §18.35 not_captured
- [67] §18.35 not_captured
- [68] §18.37.040 (City PDF Chapter 18.37)
- [69] §18.37.100 (City PDF Chapter 18.37)
- [70] §18.37.080 — 'not restricted'
- [71] §18.37.060 (City PDF Chapter 18.37)
- [72] §18.37.020 & §18.37.050 (min 25 du/ac, max 100 du/ac, avg ≥50 du/ac)
- [73] §18.37 not explicitly stated; AB 2097 applies within 0.5mi BART
- [74] §18.36 SEE not_captured — search snippet references only
- [75] §18.36 SEE (search snippet: 'maximum height of buildings shall be one hundred (100) feet')
- [76] §18.36 SEE not_captured
- [77] §18.36 SEE (search snippet: 'FAR range is between 0.40 and 3.0')
- [78] §18.36 SEE — employment district, not residential
- [79] §18.36 not_captured
- [80] §18.40 not_captured — ecode360 blocked
- [81] §18.40 not_captured
- [82] §18.40 not_captured
- [83] §18.40 not_captured
- [84] §18.40 not_captured
- [85] §18.40 not_captured
- [86] §18.40 not_captured
- [87] §18.40 not_captured
- [88] §18.40 not_captured
- [89] §18.40 not_captured
- [90] §18.40 not_captured
- [91] §18.40 not_captured
- [92] §18.40 not_captured
- [93] §18.40 not_captured
- [94] §18.40 not_captured
- [95] §18.XX not_captured — open space districts typically exempt from residential dimensional standards
- [96] §18.XX not_captured
- [97] §18.XX not_captured
- [98] §18.XX not_captured
- [99] §18.XX not_captured
Research status
Publication gates
| primary url present | passed | source.primary_url = https://ecode360.com/UN5025 — https, city's official municipal code host, not an aggregator |
|---|---|---|
| no aggregator cited | passed | scan clean — no zoneomics, steadily, siteplanguide, or other aggregator domains present |
| confidence tags full form | passed | all confirmed (c§) fields carry section citations (§18.20, §18.30, §18.36, §18.37, §18.88, §18.106, §18.98); partial (p§) fields carry retrieval reason |
| overlays have parameters trigger confidence | passed | all 5 overlays have non-empty params, trigger, confidence, and ordinance fields |
| preempt section city specific | passed | 8 CA preemption laws with city-specific qualifying_condition_checked: pop 72874/2020 Census, HCD 6th cycle status, BART station verification, SB 423 tier=50%, ADU Ch.18.34 reference |
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.