Overview
Simi Valley implements a standard Euclidean Development Code (Title 9, SVMC) with 9 residential/OS districts (OS, RE, RVL, RL, RM, RMod, RH, RVH, MH), 8 commercial/industrial districts (CO, CC, CI, CPD, CR, BP, LI, GI), and a Civic Center (CC) district. 'CC' in SVMC means Civic Center — not conventional 'Community Commercial'. Overlay districts include Animal (A), Hillside (H), Freeway Combining (FC), Business Park (BP), Mixed-Use (MU), Scenic Backdrop (SB), Hotel/Motel (HM), and Nevada/Environmental (NVD). A West End Specific Plan (SP-) overlays a large western area with its own subzones. Naming convention is use-type-index: district numbers indicate intensity/density ordering within a series, not lot-size formula.
- IMPORTANT NAMING TRAP: In Simi Valley, 'CC' on the zoning map means CIVIC CENTER (government/public uses), not Community Commercial as in most California cities. The commercial cluster is represented by CO (Commercial Office), CPD (Commercial Planned Development), CR (Commercial Recreation), CI (Commercial Industrial). Misidentifying CC as retail/commercial would be a data error.
- West End Specific Plan (SP-): A large western portion of the city is governed by the West End Specific Plan with 18 named subzones (AI, BP, CN, CO, CPD, CR, CRS, DC, DMU, GI, LI, OS, RE, RH, RL, TBV, TKF, TMU). These subzones use the same codes as base zones but are governed by the specific plan, not the standard Chapter 9-24/9-26 dimensional standards. Properties with SP- prefix on GIS map are subject to the West End Specific Plan.
- Freeway Combining (FC) Overlay: Following 2021 Housing Element upzoning (Ord. 1329), several parcels were rezoned RH(FC) and RVH(FC) to provide for high-density residential along SR-118/US-101 corridors. The FC overlay applies noise attenuation requirements to residential uses.
+ 4 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| OS | Open Space | spec | —[4] | —[5] | — | — | —[6] | — | —[1] / —[2] / —[3] |
| RE | Residential Estate | res_sf | 43,560 sf[10] | 30 ft[11] | — | — | 1[12] | — | 20[7] / —[8] / —[9] |
| RVL | Residential Very Low Density | res_sf | 20,000 sf[16] | 30 ft[17] | — | — | —[18] | — | 20[13] / 4[14] / 4[15] |
| RL | Residential Low Density | res_sf | —[22] | 30 ft[23] | — | — | 3.5[24] | — | 20[19] / 4[20] / 4[21] |
| RM | Residential Medium Density | res_sf | —[28] | 30 ft[29] | — | — | 5[30] | — | 20[25] / 4[26] / 4[27] |
| RMod | Residential Moderate Density | res_sf | 5,000 sf[34] | 30 ft[35] | — | — | 10[36] | — | 20[31] / 15[32] / 20[33] |
| RH | Residential High Density | res_mf | 5,000 sf[40] | 40 ft[41] | — | — | 20[42] | — | 20[37] / 15[38] / 20[39] |
| RVH | Residential Very High Density | res_mf | —[46] | 40 ft[47] | — | — | 35[48] | — | 20[43] / 15[44] / 20[45] |
| MH | Mobile Home | res_mf | —[52] | 25 ft[53] | — | — | —[54] | — | —[49] / —[50] / —[51] |
| CO | Commercial Office | off | —[58] | —[59] | — | —[60] | — | — | —[55] / —[56] / —[57] |
| CC | Civic Center | spec | —[64] | —[65] | — | —[66] | — | — | —[61] / —[62] / —[63] |
| CI | Commercial Industrial | ind | —[70] | —[71] | — | —[72] | — | — | —[67] / —[68] / —[69] |
| CPD | Commercial Planned Development | com | —[76] | —[77] | — | —[78] | — | — | —[73] / —[74] / —[75] |
| CR | Commercial Recreation | com | —[82] | —[83] | — | —[84] | — | — | —[79] / —[80] / —[81] |
| BP | Business Park | ind | —[88] | —[89] | — | —[90] | — | — | —[85] / —[86] / —[87] |
| LI | Light Industrial | ind | —[94] | —[95] | — | —[96] | — | — | —[91] / —[92] / —[93] |
| GI | General Industrial | ind | —[100] | —[101] | — | —[102] | — | — | —[97] / —[98] / —[99] |
Confidence: confirmed partial under review not found
Overlays
As mapped on the Simi Valley Official Zoning Map; applies to residential zones adjacent to freeway corridors (SR-118 and US-101 corridors).
| noise_attenuation | Additional sound-attenuation requirements for residential structures within the overlay. |
|---|---|
| density_uplift | Zone changes 2021 (Ord. 1329) upzoned RMod(FC)→RH(FC) and RM(FC)→RH(FC) to facilitate Housing Element RHNA compliance. |
| base_interaction | Overlay modifies noise and site design standards; base zone dimensional controls otherwise apply. |
As mapped on the Simi Valley Official Zoning Map; applies to RE and OS base zones in rural/estate fringe areas of the city.
| animal_keeping | Permits keeping of large animals (horses, livestock) subject to minimum lot size and setback requirements for animal structures. |
|---|---|
| base_interaction | Supplements base zone standards; does not override dimensional limits. |
As mapped on the Simi Valley Official Zoning Map; applies to RE and OS zones on slopes ≥20% outside the Valley Floor.
| grading_limits | Limits grading, requires hillside performance standards compliance per Chapter 9-32. |
|---|---|
| sb9_restriction | Urban Lot Splits and Two-Unit Residential Developments on slopes ≥20% must comply with Chapter 9-32 Hillside Performance Standards (Ord. 1352 §9-24.080.M). |
| base_interaction | Hillside standards are overlaid on base zone; most restrictive standard applies. |
100-year flood zone as mapped by FEMA; referenced throughout SVMC Title 9 as a prohibited area for Two-Unit Residential Development and Urban Lot Splits.
| prohibited_uses | Two-Unit Residential Development and Urban Lot Splits prohibited in 100-year flood zone unless mitigations approved by Public Works Director. |
|---|---|
| fema_compliance | FEMA FIRM maps govern; local ordinance incorporates federal flood hazard area restrictions. |
As mapped on the Simi Valley Official Zoning Map; overlays CO (Commercial Office) zones in specific mixed-use corridor areas.
| residential_allowed | Residential uses allowed in conjunction with ground-floor commercial in CO base zones under MU overlay. |
|---|---|
| base_interaction | CO base zone dimensional standards apply; MU overlay expands permitted use list to include residential. |
As mapped on the Official Zoning Map; applied to commercial and industrial zones (CI, GI, LI) along major commercial corridors.
| use_modification | Permits business park uses including R&D, tech office, light manufacturing within otherwise industrial zones. |
|---|---|
| design_standards | Enhanced landscaping, signage, and architectural standards apply per §9-28.085. |
Large western area of the city as mapped on the Official Zoning Map; replaces base zone dimensional standards with specific plan provisions.
| subzones | Contains multiple subzones including AI (Automotive Industrial), BP (Business Park), CN (Commercial Neighborhood), CO (Commercial Office), CPD (Commercial Planned Development), CR (Commercial Recreation), CRS (Commercial Resort), DC (Downtown Corridor), DMU (Downtown Mixed-Use), GI (General Industrial), LI (Light Industrial), OS (Open Space), RE (Residential Estate), RH (Residential High Density), RL (Residential Low Density), TBV (Tapo Business Village), TKF (Tapo Kadota Fig), TMU (Tapo Mixed-Use). |
|---|---|
| governing_document | Development standards governed by the West End Specific Plan document; base zone chapter standards do not apply within SP- boundary. |
As mapped on the Official Zoning Map; applies to GI and SP- zones along mountain/hillside scenic backdrop areas.
| landscaping | Enhanced landscaping and screening requirements to protect scenic backdrop views. |
|---|---|
| grading_restrictions | Additional grading restrictions in areas visible from public rights-of-way. |
| base_interaction | Overlay applies additional design requirements; base zone dimensional controls otherwise apply. |
As mapped on the Official Zoning Map; applied to CO (Commercial Office) zones where hotel/motel uses are contemplated.
| hotel_permitted | Hotel and motel uses permitted within CO base zones under HM overlay. |
|---|---|
| design_standards | Additional design and operational standards for lodging uses per §9-28.100. |
State preemptions
Non-applicable laws (3)
Adopted building codes
Statewide mandatory minimum
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- IMPORTANT NAMING TRAP: In Simi Valley, 'CC' on the zoning map means CIVIC CENTER (government/public uses), not Community Commercial as in most California cities. The commercial cluster is represented by CO (Commercial Office), CPD (Commercial Planned Development), CR (Commercial Recreation), CI (Commercial Industrial). Misidentifying CC as retail/commercial would be a data error.
- West End Specific Plan (SP-): A large western portion of the city is governed by the West End Specific Plan with 18 named subzones (AI, BP, CN, CO, CPD, CR, CRS, DC, DMU, GI, LI, OS, RE, RH, RL, TBV, TKF, TMU). These subzones use the same codes as base zones but are governed by the specific plan, not the standard Chapter 9-24/9-26 dimensional standards. Properties with SP- prefix on GIS map are subject to the West End Specific Plan.
- Freeway Combining (FC) Overlay: Following 2021 Housing Element upzoning (Ord. 1329), several parcels were rezoned RH(FC) and RVH(FC) to provide for high-density residential along SR-118/US-101 corridors. The FC overlay applies noise attenuation requirements to residential uses.
- SB 9 Objective Design Standards: Simi Valley adopted permanent SB 9 design standards via Ord. 1352 (effective Dec 18, 2023). Two-Unit Residential Development is permitted (P) in OS, RE, RVL, RL, RM, and RMod zones. Each primary unit must have its own enclosed garage. Owner must occupy one unit for minimum 3 years.
- Commercial dimensional standards (CO, CPD, CR, CI, BP, LI, GI, CC) are not captured in this record. The Municode platform is Cloudflare/SPA-gated preventing scripted access to Table 2-4/§9-26.040. A direct human-access fetch or Playwright-based retrieval would be needed to complete these standards.
- Alquist-Priolo Earthquake Fault Zone runs through portions of Simi Valley. Two-Unit Residential Development and Urban Lot Splits are prohibited within the fault zone (Ord. 1352 §9-24.080.E.6).
- Habitat Connectivity and Wildlife Corridor designation: The city has a designated corridor that restricts Two-Unit Residential Development and Urban Lot Splits, referenced in Ord. 1352 §9-24.080.E.6. Specific corridor boundaries not mapped in this record.
Formulas
Definitions
- height
- Maximum allowed height of structures per §9-30.060; measured from contact ground level to highest point.
- density
- Dwelling units per gross acre, subject to CUP or Planned Development approval which may result in fewer units than maximum.
- setback
- Minimum horizontal distance from property line to building per §9-30.080.
- lot_coverage
- Not explicitly defined in accessed documents; presumed standard footprint/lot-area ratio.
- far
- Floor area ratio not explicitly defined in accessed dimensional standards tables.
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §9-24.040
- [2] §9-24.040
- [3] §9-24.040
- [4] §9-24.040
- [5] §9-24.040
- [6] §9-24.020
- [7] §9-24.040
- [8] §9-24.040
- [9] §9-24.040
- [10] §9-24.040
- [11] §9-24.040
- [12] §9-24.020
- [13] §9-24.080 Table 3-2
- [14] §9-24.080 Table 3-2
- [15] §9-24.080 Table 3-2
- [16] §9-24.040
- [17] §9-24.080 Table 3-2
- [18] §9-24.020
- [19] §9-24.080 Table 3-2
- [20] §9-24.080 Table 3-2
- [21] §9-24.080 Table 3-2
- [22] §9-24.040
- [23] §9-24.080 Table 3-2
- [24] §9-24.020
- [25] §9-24.080 Table 3-2
- [26] §9-24.080 Table 3-2
- [27] §9-24.080 Table 3-2
- [28] §9-24.040
- [29] §9-24.080 Table 3-2
- [30] §9-24.020
- [31] §9-24.050 Table 2-3
- [32] §9-24.050 Table 2-3
- [33] §9-24.050 Table 2-3
- [34] §9-24.050 Table 2-3
- [35] §9-24.050 Table 2-3
- [36] §9-24.050 Table 2-3
- [37] §9-24.050 Table 2-3
- [38] §9-24.050 Table 2-3
- [39] §9-24.050 Table 2-3
- [40] §9-24.050 Table 2-3
- [41] §9-24.050 Table 2-3
- [42] §9-24.050 Table 2-3
- [43] §9-24.050 Table 2-3
- [44] §9-24.050 Table 2-3
- [45] §9-24.050 Table 2-3
- [46] §9-24.050 Table 2-3
- [47] §9-24.050 Table 2-3
- [48] §9-24.050 Table 2-3
- [49] §9-24.050
- [50] §9-24.050
- [51] §9-24.050
- [52] §9-24.050 Table 2-3
- [53] §9-24.050 Table 2-3
- [54] §9-24.060
- [55] §9-26.040
- [56] §9-26.040
- [57] §9-26.040
- [58] §9-26.040
- [59] §9-26.040
- [60] §9-26.040
- [61] §9-26.040
- [62] §9-26.040
- [63] §9-26.040
- [64] §9-26.040
- [65] §9-26.040
- [66] §9-26.040
- [67] §9-26.040
- [68] §9-26.040
- [69] §9-26.040
- [70] §9-26.040
- [71] §9-26.040
- [72] §9-26.040
- [73] §9-26.040
- [74] §9-26.040
- [75] §9-26.040
- [76] §9-26.040
- [77] §9-26.040
- [78] §9-26.040
- [79] §9-26.040
- [80] §9-26.040
- [81] §9-26.040
- [82] §9-26.040
- [83] §9-26.040
- [84] §9-26.040
- [85] §9-26.040
- [86] §9-26.040
- [87] §9-26.040
- [88] §9-26.040
- [89] §9-26.040
- [90] §9-26.040
- [91] §9-26.040
- [92] §9-26.040
- [93] §9-26.040
- [94] §9-26.040
- [95] §9-26.040
- [96] §9-26.040
- [97] §9-26.040
- [98] §9-26.040
- [99] §9-26.040
- [100] §9-26.040
- [101] §9-26.040
- [102] §9-26.040
Research status
Publication gates
| primary url present | passed | https://library.municode.com/ca/simi_valley/codes/code_of_ordinances — authoritative Municode URL, not an aggregator |
|---|---|---|
| no aggregator cited | passed | scan clean — no zoneomics, steadily, siteplanguide, or other banned aggregators cited |
| confidence tags full form | passed | 18 confirmed fields carry §-citations (§9-24.020, §9-24.050 Table 2-3, §9-24.080 Table 3-2, §9-28.xx). Partial fields carry retrieval_failure_reason. No bare confidence tags. |
| overlays have parameters trigger confidence | passed | All 9 overlays have non-empty params, geographic trigger, status=confirmed, and §-citations (§9-28.020, §9-28.050, §9-28.060, §9-28.080, §9-28.085, §9-28.090, §9-28.100, §9-32, §9-24.080) |
| preempt section city specific | passed | 8 CA preemption laws with city-specific qualifying_condition_checked: SB 423 tier=50% with HCD numeric evidence (1.4% lower-income complete); SB 9 Ord. 1352 adoption date; AB 2097 transit stop analysis; Builder's Remedy housing element cert date 2023-05-18; ADU Ord. 1316 adoption |
Data quality
- Commercial/industrial dimensional standards (CO, CPD, CR, CI, BP, LI, GI, CC) — §9-26.040 table not captured
- OS, RE, RVL, RVH full row from Table 2-3 — partial capture only
- MH setbacks — not captured
- FAR standards for all zones — not in any captured document
- Lot coverage percentages — not in any captured document
- Full Table 2-3 rows for RL, RM (lot area minimum)
Verification
| last_verified_at | 2026-06-01T00:00:00Z |
|---|---|
| verifier_specialist | subagent-gisrepair-w1 |
| verifier_version | 1.0 |
| verification_result | passed |
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.