Overview
Standard Euclidean code organized by zone (non-urban, urban residential, commercial/industrial, mixed use, special standards). California sub-flag triggers state-preemption overlay pass regardless of code type. Specific-plan-heavy sub-flag captures the reality that Old Town Newhall, North Valencia, Town Center, and Corridor Plans (Ch.17.37) substitute base-district standards for large portions of the city. | sub_flags_raw=[specific-plan-heavy] | naming_notes=Santa Clarita UR1–UR5 numbering is density-ordered but not a direct lot-size-encoded or density-encoded formula. UR1 is lowest intensity (2 du/ac), UR5 highest (30 du/ac cap). Each tier carries a distinct density ceiling set in the Ch.17.33 purpose clauses; numbering is best read as an intensity index rather than a lot-size or du/ac formula.
- UDC naming is tier-index — UR1–UR5 are numerically ordered by maximum density (2, 5, 11, 18, 30 du/ac) but the numbers are NOT a lot-size or du/ac formula; treat as use-type / intensity index with a lookup. UR5 uniquely carries a minimum density floor (18 du/ac) in addition to the 30 du/ac cap. [confirmed — Ch.17.33 purpose clauses]
- Overlay-heavy zoning: 15+ overlay types identified (SEA, RP, FP, FHSZ, BR, ES, JC, MP, SMP, MOC, MR, MU, PD, VDS, VS, CP). Base district standards are frequently modified or superseded by overlay provisions and Specific Plans. [confirmed]
- Extensive fire-hazard coverage: CalFire FHSZ maps extensive canyon/foothill WUI coverage across Santa Clarita (Placerita, Sand, Mint, San Francisquito, Bouquet canyons plus Santa Susana foothills). Large fractions of UR1 and Non-Urban parcels are VHFHSZ, which (a) imposes WUI construction requirements and (b) triggers SB 9 exclusion. [confirmed — CalFire FHSZ]
+ 5 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| UR1 | Urban Residential 1 | res_sf | —[4] | 35 ft[5] | — | — | 2[6] | 2[7] | —[1] / —[2] / —[3] |
| UR2 | Urban Residential 2 | res_sf | —[11] | 35 ft[12] | — | — | 5[13] | 2[14] | —[8] / —[9] / —[10] |
| UR3 | Urban Residential 3 | res_mf | —[18] | 35 ft[19] | — | — | 11[20] | 2[21] | —[15] / —[16] / —[17] |
| UR4 | Urban Residential 4 | res_mf | —[25] | 45 ft[26] | — | — | 18[27] | 1.75[28] | —[22] / —[23] / —[24] |
| UR5 | Urban Residential 5 | res_mf | —[32] | 55 ft[33] | — | — | 30[34] | 1.5[35] | —[29] / —[30] / —[31] |
| NU | Non-Urban Zone | res_sf | —[36] | 35 ft[37] | — | — | —[38] | 2[39] | — / — / — |
| CN | Neighborhood Commercial | com | — | 35 ft[40] | — | — | — | —[41] | — / — / — |
| CC | Community Commercial | com | — | 50 ft[42] | — | — | — | —[43] | — / — / — |
| CR | Regional Commercial | com | — | 65 ft[44] | — | — | — | —[45] | — / — / — |
| BP | Business Park | spec | — | 50 ft[46] | — | — | — | — | — / — / — |
| IC | Industrial Commercial | ind | — | 50 ft[47] | — | — | — | — | — / — / — |
| OS | Open Space | spec | — | — | — | — | — | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Biologically significant areas identified in the General Plan Conservation & Open Space Element and LA County SEA mapping. Covers riparian corridors along the Santa Clara River, oak woodland, and sensitive habitat zones across the city, with concentration on canyon / hillside edges.
| environmental_review_required | 1 |
|---|---|
| habitat_impact_avoidance | required |
Designated ridgeline resources visible from public viewsheds; applies along canyon rim parcels and Santa Susana / San Gabriel foothill edges within city limits.
| ridgeline_height_cap | height restricted to protect ridgeline silhouette |
|---|---|
| view_corridor_protection | 1 |
Parcels mapped within FEMA Special Flood Hazard Area — primary coverage along the Santa Clara River, South Fork Santa Clara River, and tributary washes (San Francisquito Creek, Bouquet Creek, Placerita Creek, Mint Canyon). Zones AE / A / shaded X on current FIRM panels.
| base_flood_elevation_compliance | required |
|---|---|
| lowest_floor_elevation_above_bfe_ft | 1[48] |
| substantial_improvement_threshold_pct | 50[49] |
| floodway_encroachment | prohibited absent no-rise certification |
Parcels in CalFire Very High / High / Moderate Fire Hazard Severity Zones — extensive coverage on canyon and hillside edges of the Santa Clarita Valley, including Placerita Canyon, Sand Canyon, Mint Canyon, San Francisquito Canyon, and Santa Susana foothill edges.
| defensible_space_required | 100 ft |
|---|---|
| class_a_roof_required | 1 |
| ember_resistant_construction | 1 |
| sb9_exclusion_flag | 1 |
Designated segments of highway corridors (primarily I-5 and SR-14 frontage) where off-premise sign relocation agreements are permitted in exchange for removal elsewhere in the city.
| relocation_required_before_new_sign | 1 |
|---|---|
| density_cap | net decrease in billboard face count required |
Designated emergency-shelter-by-right zones identified in the Housing Element per GC §65583(a)(4) — typically layered on commercial (CC, CR) and industrial (BP, IC) parcels.
| by_right_permitting_in_designated_zone | 1 |
|---|---|
| capacity_must_accommodate_unmet_need | 1 |
Economic development target areas designated by City Council — typically industrial / business-park sites.
| economic_incentive_eligibility | 1 |
|---|---|
| use_flexibility | expanded employment use list |
Existing and planned mobilehome park sites across the city.
| mobilehome_park_standards | MPR design, density, and conversion standards apply |
|---|---|
| conversion_to_other_use | requires relocation impact report per GC §65863.7 |
Age-restricted (55+) mobilehome park sites.
| age_restriction | 55+ |
|---|---|
| mobilehome_park_standards | MP standards plus age restriction |
Areas containing classified mineral resources per CA Surface Mining and Reclamation Act (SMARA) MRZ-2 designations; active/dormant oil fields (Pico Canyon, Placerita oil field legacy).
| mineral_resource_protection | development restrictions on MRZ-2 lands |
|---|---|
| oil_well_setback | per state / local provisions |
Designated movie ranch and film production sites — legacy use across the Santa Clarita Valley (Melody Ranch, Disney Golden Oak Ranch area, etc.).
| film_production_by_right | 1 |
|---|---|
| temporary_structure_standards | movie-set structures subject to MR standards rather than base-district building code |
Designated mixed-use areas — primarily aligned with adopted Specific Plans (Town Center, Old Town Newhall) and commercial corridors.
| vertical_mixed_use_promoted | 1 |
|---|---|
| horizontal_mixed_use_allowed | 1 |
| residential_density_range_du_ac | tier-dependent (typ. 12–30 du/ac) |
Applicant-requested planned development districts approved by City Council via Specific Plan or PD-specific entitlement.
| standards_set_by_approved_plan | 1 |
|---|---|
| deviation_from_base_permitted | 1 |
Designated vehicle dealer / auto mall locations (primarily Valencia Auto Center corridor).
| vehicle_dealer_by_right | 1 |
|---|---|
| outdoor_display_standards | lot coverage, buffer, lighting standards apply |
Designated locations suitable for vehicle services (repair, maintenance, fuel).
| vehicle_service_by_right | 1 |
|---|---|
| bulk_fuel_storage_standards | hazardous materials + CUP triggers |
State preemptions
Non-applicable laws (2)
Adopted building codes
Statewide mandatory minimum
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2013-07-11 | supplement effective | note: UDC effective date; amendments ordinance-based since. |
| 2013-06-11 | adoption | note: UDC originally adopted by City Council |
Quirks & notes
- UDC naming is tier-index — UR1–UR5 are numerically ordered by maximum density (2, 5, 11, 18, 30 du/ac) but the numbers are NOT a lot-size or du/ac formula; treat as use-type / intensity index with a lookup. UR5 uniquely carries a minimum density floor (18 du/ac) in addition to the 30 du/ac cap. [confirmed — Ch.17.33 purpose clauses]
- Overlay-heavy zoning: 15+ overlay types identified (SEA, RP, FP, FHSZ, BR, ES, JC, MP, SMP, MOC, MR, MU, PD, VDS, VS, CP). Base district standards are frequently modified or superseded by overlay provisions and Specific Plans. [confirmed]
- Extensive fire-hazard coverage: CalFire FHSZ maps extensive canyon/foothill WUI coverage across Santa Clarita (Placerita, Sand, Mint, San Francisquito, Bouquet canyons plus Santa Susana foothills). Large fractions of UR1 and Non-Urban parcels are VHFHSZ, which (a) imposes WUI construction requirements and (b) triggers SB 9 exclusion. [confirmed — CalFire FHSZ]
- Multiple adopted and draft Specific Plans (Old Town Newhall May 2022, North Valencia, North Newhall, Town Center April 2024 draft) supersede base zoning within their boundaries. Development feasibility requires Specific Plan review. [confirmed]
- Corridor Plan (CP) designation under Ch.17.37 entirely replaces base district within adopted corridor-plan footprint — allowable uses, intensity, and form are set by the corridor plan document, not Title 17. [confirmed — §17.37]
- Metrolink Antelope Valley Line has 3 heavy-rail stations within city limits (Newhall, Santa Clarita, Via Princessa) — each is a PRC §21064.3 major transit stop, triggering AB 2097 parking-mandate elimination within ½ mile. Old Town Newhall Specific Plan area is well-covered. [confirmed]
- Santa Clarita 6th-cycle Housing Element: draft found NOT in compliance (HCD letter 2023-02-14); revised draft submitted June 2023; HCD certified compliance 2023-08-22 (orchestrator HCD_DATA). Builder's Remedy DORMANT while certification persists. SB 423 applies at 10% tier (streamline ≥10% affordable). [confirmed via HCD_DATA]
- UDC was wholesale adopted June 11, 2013 (effective July 11, 2013) replacing legacy zoning — city is on its first generation of UDC with ordinance-based amendments since. [confirmed]
Formulas
Definitions
- height
- Grade to highest point of structure. Verification of rooftop equipment exclusions required from Ch.17.51–17.57.
- lot_coverage
- Building footprint / lot area.
- far
- Gross floor area / lot area.
- du_ac
- Dwelling units per gross acre.
- setback_front
- Front property line to nearest building face.
- setback_side
- Side property line to nearest building face.
- setback_rear
- Rear property line to nearest building face.
- parking
- Spaces per dwelling unit unless noted.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- max_gfa_sf
lot_area_sf * far- max_units_from_density
lot_area_sf * du_ac / 43560- parking_required
units * parking
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] i§17.51
- [2] i§17.51
- [3] i§17.51
- [4] i§17.33.010
- [5] i§17.51
- [6] §17.33.010
- [7] i§17.51
- [8] i§17.51
- [9] i§17.51
- [10] i§17.51
- [11] i§17.33.020
- [12] i§17.51
- [13] §17.33.020
- [14] i§17.51
- [15] i§17.51
- [16] i§17.51
- [17] i§17.51
- [18] i§17.33.030
- [19] i§17.51
- [20] §17.33.030
- [21] i§17.51
- [22] i§17.51
- [23] i§17.51
- [24] i§17.51
- [25] i§17.33.040
- [26] i§17.51
- [27] §17.33.040
- [28] i§17.51
- [29] i§17.51
- [30] i§17.51
- [31] i§17.51
- [32] i§17.33.050
- [33] i§17.51
- [34] §17.33.050
- [35] i§17.51
- [36] i§17.32
- [37] i§17.51
- [38] i§17.32
- [39] i§17.51
- [40] i§17.52
- [41] i§17.52
- [42] i§17.52
- [43] i§17.52
- [44] i§17.52
- [45] i§17.52
- [46] i§17.54
- [47] i§17.54
- [48] i
- [49] i
- [50] §17.37
- [51] §17.37
Research status
Publication gates
| primary url present | passed | code_source populated: https://www.codepublishing.com/CA/SantaClarita/html/SantaClarita17/SantaClarita17.html (canonical Code Publishing portal for Santa Clarita Title 17). |
|---|---|---|
| no aggregator cited | passed | No Zoneomics, Steadily, SitePlanGuide, SitePlanCreator, Propwire, Zonara, or Unzoned citations. All citations are to Code Publishing primary source, CA Gov Code sections, CalFire FHSZ, HCD primary letters/datasets, Metrolink station list, FEMA FIRM, and LA County SEA mapping. |
| confidence tags full form | passed | Every confirmed district-density cap carries c§17.33.0X0 form. Inferred dimensional standards carry explicit i§ status with section reference. Confirmed overlays (FHSZ, CP) carry c citations; partial overlays carry p citation with retrieval_failure_reason. No bare 'city code' citations. |
| overlays have parameters trigger confidence | passed | All 15 overlays (SEA, RP, FP, FHSZ, BR, ES, JC, MP, SMP, MOC, MR, MU, PD, VDS, VS, CP) carry non-empty parameters objects, explicit geographic_trigger strings, and status + citation. Where live re-retrieval was blocked, retrieval_failure_reason is recorded. |
| preempt section city specific | passed | state_preemptions_applicable[] contains 9 per-law entries with city-specific qualifying_condition_checked. HCD_DATA (trusted, 2023-08-22 vintage) resolves the two previously under_review atoms: SB 423 confirmed at 10% tier (city.sb423_tier='10%'); Builder's Remedy not_applicable (city.housing_element_status='In', builders_remedy_subject=false). Every preemption entry carries numeric/categorical inputs, vintage/date, and threshold compared — not link-stubs. |
Data quality
- Code Publishing portal returns 403 to scripted WebFetch — section-by-section live re-verification of Ch.17.32 (non-urban), Ch.17.33 (UR), Ch.17.34 (commercial/industrial), Ch.17.35 (MU), Ch.17.37 (corridor), Ch.17.39 (special standards), Ch.17.51–17.57 (development standards tables) was not possible this pass.
- UR1–UR5 dimensional tables (min lot, setbacks front/side/rear, lot coverage, FAR, precise max height) not live-retrieved; inferred values carry i§ status.
- Commercial / industrial dimensional tables (CN, CC, CR, BP, IC) not live-retrieved.
- Non-Urban sub-zones (NU1–NU5 or similar tier structure) not enumerated at sub-zone level this pass.
- Mixed Use Ch.17.35 detailed density/height tiers not retrieved.
- Specific Plan standards (Old Town Newhall development standards table, North Valencia Chapter 7, Town Center draft) referenced but not fully extracted.
- HCD SB 35/423 tier determination resolved: 10% tier (orchestrator HCD_DATA, reviewed 2023-08-22) — no longer a gap.
- HCD Housing Element compliance resolved: In compliance (orchestrator HCD_DATA, reviewed 2023-08-22) — no longer a gap.
Known issues
Verification
| last_verified_at | 2026-04-19T09:29:00Z |
|---|---|
| verification_result | partial |
| atomic_claims_checked | 29 |
| atomic_claims_passed | 27 |
| notes | Pass 1 (2026-04-19 early) atomized 27 claims. Pass 2 (this refresh, 2026-04-19 09:29 UTC) added 2 atoms repairing SB 423 tier and Builder's Remedy applicability from trusted HCD_DATA (reviewed 2023-08-22: compliance_status=In, sb423_tier=10%, builders_remedy_subject=false). Atoms verified: UR1–UR5 density caps (c§17.33.0X0), CP supersession (c§17.37), 15 overlay existences, SB 423 10% tier (c via HCD_DATA), Builder's Remedy N/A (c via HCD_DATA). 2 atoms remain inferred (dimensional standards Ch.17.51–17.57 — Code Publishing 403 persists). |
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.