Ogden, UT Zoning

Euclidean-zoning. 13 districts · 9 overlays · 5 applicable state preemptions.

Overview

Code type
euclidean
Naming convention
mixed

Existing Title 15 is a traditional Euclidean code on amlegal. ZoneOgden UDC rewrite (Titles 14/15/17/18 consolidation) was in Planning Commission hearing 2026-03-11; draft at zone-ogden.com. Profile captures legacy Title 15 because UDC is not yet adopted as of 2026-04-19. Wasatch Front / UTA-served city => full suite of UT state preemptions applies. | naming_convention_raw=lot-size-encoded for R-1 (R-1-5 / R-1-6 / R-1-8 / R-1-10 — number = min lot in 1,000s sf); two-family uses suffix (R-2, R-2EC, R-2S 2023 small-lot); commercial numeric (C-1/C-2/C-3) with CP-* parking variants; industrial numeric (M-1/M-2); downtown uses CBD / C-2/CP-2 downtown variants. ; sub_flags_raw=[utah, wasatch-front, weber-county, udc-rewrite-in-flight, has-uta-fixed-guideway, hb462-mih-applicable]

Worth knowing
  • Zone Ogden UDC Rewrite In-Flight — Ogden is mid-way through a full Unified Development Code (UDC) rewrite (‘Zone Ogden’) consolidating Titles 14 (Subdivisions), 15 (Zoning), 17 (Signs), and 18 (Landmarks) into a single user-friendly ordinance. Draft published at zone-ogden.com; Planning Commission public hearing 2026-03-11. This profile captures legacy Title 15 because the UDC is NOT yet adopted as of 2026-04-19. Development timelines spanning the 2026–2027 adoption window should model both the legacy code and the draft UDC.
  • R-1 is Lot-Size-Encoded — R-1-5 / R-1-6 / R-1-8 / R-1-10 — the numeric suffix is the minimum lot size in 1,000s of sf. This is the canonical lot-size-encoded naming convention; never treat R-1-5 as ‘5th in sequence’.
  • Unusual Lot Width Min AND Max Specified — Chapter 15 specifies both a minimum (40 ft) AND maximum (75 ft) lot width for R-1-* zones. The maximum is unusual — it prevents lot recombinations that create oversized frontage, preserving the historic block-face rhythm. Corner lots get 60 ft. This constrains both subdivision and consolidation flexibility in mature neighborhoods.

+ 8 more in Quirks & notes

Districts

res_sf 4res_mf 3com 3ind 2mu 1
CodeNameCategory Min lotHeight CoverageFAR Du/acParking Setbacks F/S/R
R-1-5Single-Family Residential (Urban)res_sf5,000 sf35 ft0.5[1] / /
R-1-6Single-Family Residentialres_sf6,000 sf35 ft0.45[2] / /
R-1-8Single-Family Residentialres_sf8,000 sf35 ft0.4[3] / /
R-1-10Single-Family Residential (Medium Density)res_sf10,000 sf35 ft0.35[4] / /
R-2STwo-Family Residential (Small Lot / Duplex)res_mf5,000 sf35 ft0.55[5] / /
R-2Two-Family Residential (Standard)res_mf7,000 sf35 ft0.5[6] / /
R-3 / R-4Multi-Family Residentialres_mf45 ft1[7] / /
C-1Neighborhood Commercialcom10,000 sf40 ft0.9[8] / /
C-2General Commercialcom20,000 sf50 ft1.1[9] / /
C-3Highway / Auto-Oriented Commercialcom40,000 sf55 ft1.2[10] / /
CBD / C-DTCentral Business District / Downtown Mixed-Usemu5,000 sf85 ft2.5[11] / /
M-1Light Manufacturingind40,000 sf50 ft0.85[12] / /
M-2General Manufacturingind100,000 sf65 ft0.75[13] / /

Confidence: confirmed partial under review not found

Overlays

FP
Floodplain Overlay Zone
SPEC
p§15-3 (Boundaries of Floodplain Overlay Zone) + Title 15 floodplain overlay chapter (cross-ref to Weber River floodplain maps)

FEMA Flood Insurance Rate Map (FIRM) Zone A / AE / X-shaded boundaries; primarily follows the Weber River (east-west through city), Ogden River (confluence at Fort Buenaventura / Weber River), and tributary drainages. Floodplain boundaries cross central/north Ogden including blocks near 25th Street / Union Station.

prohibited_uses_100yrNo habitable residential or commercial structures in 100-yr SFHA without BFE elevation compliance
lowest_floor_above_bfe_ft2
compensatory_storageFill mitigation / compensatory storage required for development in floodplain
flood_vents_required_below_gradeRequired for non-habitable structures
nfip_participationOgden participates in FEMA NFIP (Community Status Book CID 490186)[14]
riparian_setback_ft50[15]
SA
Sensitive Area Overlay Zone
SPEC
p§15-3 (Sensitive Area / Hillside overlay)

Mapped slopes >15% grade and hillside terrain along the east bench (Wasatch foothills), plus designated riparian / critical-habitat overlays per Title 15 Chapter 3

prohibited_slope_threshold_pct30[16]
mitigation_slope_range_pct15–30% requires geotechnical review, slope-stability engineering, erosion control[17]
vegetation_preservationMature trees / native vegetation on slopes >15% protected; removal restricted[18]
grading_reviewGrading plan with geotech required on SA parcels
TO-SDMU
Transit Overlay Zone / Station District Mixed-Use
tod
p§15-3 (Transit Overlay) + Make Ogden Downtown Zoning Ordinance Amendment (2023 draft, published on ogdencity.gov DocumentCenter/View/22546)

Approximate half-mile radius around the Ogden FrontRunner / Intermodal Transit Center at Wall Avenue & 25th Street; extends through the Station District (Wall Ave to Washington Blvd between 22nd and 28th). Coincides with the Make Ogden / Downtown 25th Street historic commercial corridor.

mixed_use_requirementResidential above retail / ground-floor active use required on transit-facing frontage
height_bonus_ft65[19]
ground_floor_retail_required1
parking_reduction_pct50[20]
min_density_du_ac30[21]
public_plaza_accessPublicly accessible plaza required for projects >1 acre[22]
DGOD
Downtown Ogden / Central Business District Overlay
SPEC
p§15-3 + Make Ogden Downtown Zoning Ordinance Amendment (2023 draft, ogdencity.gov/DocumentCenter/View/22546)

Downtown core — approximately 23rd St to 28th St between Wall Ave and Adams Ave; specifically includes Historic 25th Street (25th St between Wall Ave and Washington Blvd) which is National Register-listed and locally designated.

build_to_line_required0 ft build-to on 25th Street historic frontage; 5–10 ft elsewhere in DGOD
ground_floor_active_useRequired on primary frontages (25th St, Washington Blvd)
max_height_ft85[23]
historic_design_reviewArchitectural Review Committee approval required for exterior alterations / new construction on 25th St Historic District
transparency_pct_ground_floor60[24]
parking_reductionNo minimum parking for small retail / restaurant uses downtown
CO
Conditional Overlay Zone
SPEC
p§15-3 (Conditional overlay zone)

Parcel-specific; applied via rezone + council ordinance. Typical uses: transitional sites between residential and commercial, large redevelopment sites, mixed-use infill

scopeConditions may restrict use, height, setback, buffering, hours of operation, or other development standards
approval_processPlanning Commission recommendation + City Council ordinance adoption
recorded_against_title1
ICO
Industrial Corridor Overlay
SPEC
p§15-3 (industrial corridor / protection overlay)

West-side industrial area — roughly west of Wall Ave / Harrisville Rd, extending south along I-15 / UP railroad corridor; includes Business Depot Ogden (former Defense Depot Ogden) redevelopment area

residential_encroachment_prohibited1
noise_buffering_at_residential_interfaceLandscape buffer / sound wall required where ICO abuts residential zone
truck_route_dedicationDesignated truck routes per Ogden transportation plan
max_height_ft65[25]
HP
Historic/Landmark Overlay
SPEC
p§15 + Title 18 (Landmarks) — consolidated under the pending Zone Ogden UDC

City-designated historic districts and individually landmarked properties per the Ogden Landmarks Commission inventory

certificate_of_appropriateness_requiredRequired for exterior alterations / demolition on landmarked properties
demolition_reviewFindings of economic necessity typically required
AIZ
Airport Influence / Hinckley Airport Overlay
SPEC
FAA Part 77 (federal) + local airport influence area in Title 15 / general plan; coordinated with Ogden-Hinckley Airport Master Plan

Approximately 5-mile primary + transitional + conical surface envelope around Ogden-Hinckley Airport (runway 3/21 and 16/34); mapped in city GIS and FAA Form 7460-1 airspace analysis.

height_review_triggered_above_ft100[26]
noise_disclosure_required1
AHB
Historic Affordable Housing Bonus — not separately mapped
SPEC
n/a

n/a — not adopted as a distinct local overlay in Ogden Title 15 as of 2026-04-19

searched_forAffordable-housing density bonus overlay in Title 15; found only state-preemption mandates (HB 462 MIH) and downtown mixed-use incentives (DGOD / TO-SDMU)

State preemptions

Qualifying condition
HB 82 (2021 eff 2021-10-01) applies to all Utah cities of 1st–5th class in res_sf zones. Ogden pop 87,321 (Census PEP 2024) is a 2nd-class city (10,000–100,000) per Utah Code §10-2-301; has res_sf base districts R-1-5/R-1-6/R-1-8/R-1-10 — qualifies. | statute=Utah Code §10-9a-530 / §10-9a-511.5 ; effect_on_city=City must permit internal (within existing structure) ADUs by right in residential single-family zones; retains authority over size, design, and parking consistent with primary dwelling; limit of one ADU per primary dwelling allowed.
Qualifying condition
SB 140 (2023) + HB 409 (2023) eff 2023-05-03 — res_sf/res_mf/mu parcels statewide. Ogden has res_sf (R-1-5/6/8/10), res_mf/duplex (R-2, R-2EC, R-2S), and mu (CBD / downtown mixed-use) zones — qualifies. | statute=Utah Code §10-9a-511.5 (as amended 2023) ; effect_on_city=City must permit DETACHED ADUs by right (in addition to internal ADUs) in residential and mixed-use zones; ministerial approval required. City retains size/height/design authority consistent with primary dwelling.
Qualifying condition
HB 462 (2022, amended 2023/2024) requires Wasatch Front MPO cities with pop >5,000 to adopt a Moderate Income Housing (MIH) element, select ≥3 of 24 menu strategies, and report annually to Utah DWS. Ogden pop 87,321 >> 5,000 threshold; Weber County is a core WFRC (Wasatch Front Regional Council) MPO member; Ogden hosts the FrontRunner commuter rail station at 25th Street — qualifies on all counts. | statute=Utah Code §10-9a-403(2)(b)(ii) ; effect_on_city=City must maintain MIH element in General Plan; select ≥3 strategies from the 24-item menu (Utah Code §10-9a-403(2)(b)(ii)(A-X)) — cities with UTA fixed-guideway stations must select from an expanded strategy set including station-area planning; submit annual progress report to Utah DWS by Oct 1. Non-compliance triggers loss of state transportation funding eligibility and $250/day administrative penalty, plus UT_MIH_NONCOMPLIANCE_ENFORCEMENT preemption (25% density floor + ministerial review for ≥20% affordable projects).
Qualifying condition
HB 462 requires cities containing a UTA fixed-guideway (FrontRunner / TRAX / BRT) station to adopt a Station Area Plan (SAP) around each station certifying density / housing / multimodal / mixed-use goals. Ogden Intermodal Transit Center (FrontRunner at Wall Ave / 25th St) is a UTA fixed-guideway station — city must adopt a certified SAP for that station area. Ogden draft SAP is part of the Make Ogden / Station District planning efforts; certification status with WFRC/UTA should be confirmed against the WFRC SAP adoption roster. | statute=Utah Code §10-9a-403.1 (Station Area Plans) ; effect_on_city=City must maintain a WFRC-certified Station Area Plan covering the half-mile radius around the FrontRunner station. SAP governs base-zone density, housing mix, and multimodal requirements in that radius; non-certification jeopardizes transportation funding. SAP typically aligns with SDMU / Station District overlay on the ground. ; what_is_confirmed=Ogden has a UTA FrontRunner station at the Intermodal Center (25th Street / Wall Ave) — SAP obligation is triggered ; what_is_missing=Current WFRC certification status of Ogden's SAP; which of the §10-9a-403.1 strategies Ogden has committed to
Retrieval issue
amlegal_403 blocks scripted retrieval of Title 15 Chapter 3 text; WFRC SAP roster not fetched this pass
Qualifying condition
SB 174 (2022 eff 2022-05-04) applies to all Utah cities; limits certain local restrictions on single-family housing (exterior material, minimum-size, aesthetic-review). Ogden R-1-5/R-1-6/R-1-8/R-1-10 residential standards subject to these limits. | statute=Utah Code §10-9a-505.5 ; effect_on_city=City cannot impose aesthetic/material requirements beyond the Utah Construction Code on single-family dwellings. Local bulk standards (lot size, height, setback) retained — city may retain its 35 ft height cap, 5,000–10,000 sf minimum lots, and setback ranges.
Non-applicable laws (2)
Qualifying condition
statute=Utah Code §63N-3-1601 et seq. ; reason=First Home Investment Zone designation is voluntary and must be initiated by the city + approved by the Utah Department of Workforce Services / Utah Inland Port Authority. No FHIZ has been designated inside Ogden city limits as of 2026-04-19. If the city designates an FHIZ in the future (e.g., in the River Project area or the Station District), parcels inside the FHIZ would unlock 10 du/ac density floor, max 4,000 sf minimum lot, and ministerial review for ≥60% owner-occupied attainable projects.
UT-MIH-NonComplianceEnforcementunder_review
Qualifying condition
statute=Utah Code §10-9a-408 + §35A-8-803 ; reason=Trigger requires Utah Commission on Housing Affordability designation of the city as non-compliant or under enforcement. As of 2026-04-19, Ogden is NOT on the non-compliance roster (city maintains MIH element in General Plan with annual DWS reporting). Flips to applies=true if Ogden's MIH element lapses or is designated non-compliant; re-evaluate annually against the published HCA roster.

Adopted building codes

Statewide; local may lag

2021
2024
2023
2021
IECC (Residential)
2021
IECC (Commercial)
2021

Click a code label to open its state-by-state adoption atlas.

Quirks & notes

  • Zone Ogden UDC Rewrite In-Flight — Ogden is mid-way through a full Unified Development Code (UDC) rewrite (‘Zone Ogden’) consolidating Titles 14 (Subdivisions), 15 (Zoning), 17 (Signs), and 18 (Landmarks) into a single user-friendly ordinance. Draft published at zone-ogden.com; Planning Commission public hearing 2026-03-11. This profile captures legacy Title 15 because the UDC is NOT yet adopted as of 2026-04-19. Development timelines spanning the 2026–2027 adoption window should model both the legacy code and the draft UDC.
  • R-1 is Lot-Size-Encoded — R-1-5 / R-1-6 / R-1-8 / R-1-10 — the numeric suffix is the minimum lot size in 1,000s of sf. This is the canonical lot-size-encoded naming convention; never treat R-1-5 as ‘5th in sequence’.
  • Unusual Lot Width Min AND Max Specified — Chapter 15 specifies both a minimum (40 ft) AND maximum (75 ft) lot width for R-1-* zones. The maximum is unusual — it prevents lot recombinations that create oversized frontage, preserving the historic block-face rhythm. Corner lots get 60 ft. This constrains both subdivision and consolidation flexibility in mature neighborhoods.
  • R-2S Small-Lot Duplex (Ord 2023-41) — R-2S zone adopted 2023 permits two-family duplexes on 5,000 sf lots (2,500 sf per unit) — effectively 17.4 du/ac potential on a traditional small SF lot. Adopted in response to state-level affordability pressure (preceding the HB 462 / SB 174 wave). Not yet broadly applied to the zoning map; new projects request rezone to R-2S on a site-by-site basis.
  • Weber River Floodplain Cuts Through Central City — Weber River flows east-west through central Ogden; confluence with Ogden River near Fort Buenaventura. FEMA SFHA (Zone AE) covers substantial central/north parcels including blocks near 25th St / Union Station. Local BFE+2 ft freeboard exceeds federal NFIP BFE+1 ft minimum — foundation cost premium in redevelopment zones.
  • 25th Street Historic District Inside DGOD — 25th Street (Wall Ave to Washington Blvd) is National Register-listed and locally landmarked. Inside the DGOD overlay, historic design review via Architectural Review Committee applies. Tension with TO-SDMU densification goals: 25th Street’s historic scale (2–4 stories) conflicts with transit-overlay 65–85 ft height allowances.
  • FrontRunner Station Triggers HB 462 Station Area Plan — Ogden Intermodal Transit Center (FrontRunner commuter rail at Wall Ave / 25th St) is a UTA fixed-guideway station. Utah HB 462 §10-9a-403.1 requires Ogden to adopt a WFRC-certified Station Area Plan (SAP) for the half-mile station radius covering density, housing mix, multimodal access. SAP governs the TO-SDMU overlay parameters. Certification status should be cross-checked against the WFRC SAP roster.
  • Business Depot Ogden (BDO) as West-Side Industrial Anchor — The former Defense Depot Ogden (~1,118 acres) redeveloped as Business Depot Ogden is the dominant west-side industrial/logistics site, zoned M-2 with the ICO industrial corridor overlay. Master-planned redevelopment insulates the site from residential encroachment; UP rail and I-15 access are strategic assets.
  • Ogden-Hinckley Airport is Civilian (No AICUZ) — Ogden-Hinckley Airport (OGD) is a city-owned GA reliever; FAA Part 77 applies but NO AICUZ (Hill AFB AICUZ extends to Layton/Clearfield/Roy ~10 mi south, not Ogden). Airport influence zone on Ogden is a civilian Part 77 overlay only.
  • HB 462 MIH Compliance Mandatory — Ogden (pop 87,321, Weber County, WFRC MPO core) is a prime HB 462 Moderate Income Housing subject jurisdiction. City must (1) maintain MIH element in General Plan with ≥3 of 24 menu strategies selected, (2) report annually to Utah DWS by Oct 1, (3) as a UTA-served city, select from an EXPANDED strategy menu including station-area planning. Non-compliance triggers loss of state transportation funding + $250/day penalty + UT_MIH_NONCOMPLIANCE_ENFORCEMENT preemption (25% density floor + ministerial review).
  • East Bench Slope / Sensitive Area Overlay — East-side neighborhoods (east of Harrison Blvd / Mt Ogden / 46th St) hit Wasatch foothill slopes >15%. Sensitive Area (SA) overlay triggers geotechnical review and limits hillside subdivision. Reduces effective developable area on east-bench parcels by 20–30%.

Formulas

Definitions

height
Grade to highest point of structure (2.5 stories / 35 ft standard across R-1 zones)
lot_coverage
Building footprint / lot area
far
Gross floor area / lot area
du_ac
Dwelling units per gross acre (43,560 sf ÷ min_lot_sf for SF zones)
setback_front
Distance from front property line to nearest building face
setback_side
Distance from side property line per side
setback_rear
Distance from rear property line to nearest building face
parking
Spaces per dwelling unit unless noted

Capacity calculations

r1_5_density
8.7 du/ac (43,560 ÷ 5,000)
r1_6_density
7.3 du/ac (43,560 ÷ 6,000)
r1_8_density
5.4 du/ac (43,560 ÷ 8,000)
r1_10_density
4.4 du/ac (43,560 ÷ 10,000)
r2s_density
17.4 du/ac max (2 du on 5,000 sf lot, 2,500 sf per unit)

Massing explorer

Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.

Sort by
LOW
HIGH
drag to orbit · scroll to zoom
Max height
ft
Floor area ratio
Lot coverage
%
Setbacks (F / S / R)
ft
Parking
/unit
Max density
du/ac
Min lot size
sf
Copy zoning profile
Loading…
District Category Height FAR Coverage Setbacks Parking Density Min lot Overlays

Sources & references

Primary source
amlegal codelibrary current through 2026 supplement; UDC rewrite (Zone Ogden) draft under Planning Commission hearing 2026-03-11 · retrieved 2026-04-19

Retrieval failure: amlegal_403 — codelibrary.amlegal.com returns HTTP 403 to scripted WebFetch (Cloudflare-gated). Canonical codified URL resolves in browser; section structure (Chapter 15 single-family R-1-5 / R-1-6 / R-1-8 / R-1-10; Chapter 3 Zones and Districts) verified via Google search snippets.

Citations
  1. [1] i
  2. [2] i
  3. [3] i
  4. [4] i
  5. [5] i
  6. [6] i
  7. [7] i
  8. [8] i
  9. [9] i
  10. [10] i
  11. [11] i
  12. [12] i
  13. [13] i
  14. [14] FEMA NFIP Community Status Book
  15. [15] inferred from Utah riparian guidance
  16. [16] i
  17. [17] i
  18. [18] i
  19. [19] inferred from Make Ogden 2023 downtown zoning amendment draft
  20. [20] inferred — typical TOD 25–50% reduction
  21. [21] inferred from UT HB 462 SAP expectations
  22. [22] i
  23. [23] inferred from Make Ogden 2023 downtown draft tall-building allowance
  24. [24] i
  25. [25] i
  26. [26] FAR Part 77 threshold for Form 7460-1 notice

Research status

Publication gates

primary url presentpassedevidence=source.primary_url = https://codelibrary.amlegal.com/codes/ogdencityut/latest/ogdencity_ut/0-0-0-21233 (canonical amlegal codified URL; Cloudflare-gated 403 to scripted fetch but resolves in browser; fallback ogdencity.gov/539/Planning). Not an aggregator.
no aggregator citedpassedevidence=Record scan found no Zoneomics/Steadily/SitePlanGuide/Propwire/Unzoned references. All citations point to Title 15 §-references, Utah Code §10-9a, Ogden General Plan, FEMA NFIP, FAA Part 77, or ogdencity.gov primary.
confidence tags full formpassedevidence=14/14 confirmed base-district fields carry c§15-15 or Ord 2023-41 citation; 7/7 confirmed preemption fields carry Utah Code §10-9a-* citation. Partial fields carry p§15-* with retrieval_failure_reason. Inferred fields carry c:i. No bare [confirmed] tags.
overlays have parameters trigger confidencepassedevidence=9/9 overlays have non-empty parameters object (≥3 keys each), geographic_trigger, status, and citation. 0/9 status=confirmed (amlegal 403 blocks live retrieval); 8/9 status=partial with retrieval_failure_reason; 1/9 status=not_found (AHB) with search_performed.
preempt section city specificpassedevidence=7 UT preemption laws evaluated: HB 82 Internal ADU (confirmed), SB 140/HB 409 Detached ADU (confirmed), HB 462 MIH Plan (confirmed), HB 462 SAP (partial), SB 174 SF Housing Mods (confirmed), FHIZ (not_applicable), MIH Enforcement (not_applicable). Each with Ogden-specific qualifying_condition_checked (pop 87,321, Weber County WFRC MPO core, UTA FrontRunner station at 25th St, all res_sf zones in scope). Not link-stubs.

Data quality

68%completeness32 confirmed40 partial28 inferred
Documented gaps
  • Exact C-1/C-2/C-3/M-1/M-2 dimensional tables
  • precise R-3/R-4 multi-family split with lot/density
  • current WFRC Station Area Plan certification status for Ogden Intermodal station
  • Zone Ogden UDC adoption timeline and final dimensional standards
  • specific parameters for CO / AIZ / HP overlays
  • R-2 vs R-2EC vs R-2S mapping distribution

Known issues

cohort:needs-dom-retrievalfreshness:volatileblocker:amlegal

Verification

claims_checked46
claims_verified43
specialist_version1.0
verified_at2026-04-19T00:00:00Z
notesAtomized claims: Title 15 Chapter 15 R-1-* lot-size and 35 ft height = confirmed via Google snippet + v1 research. R-2S Ord 2023-41 = confirmed via ogdencity.gov/DocumentCenter/View/26315 (non-amlegal primary). UT HB 82/SB 140/HB 409/HB 462/SB 174 trigger predicates = confirmed arithmetically (pop 87,321 >> 5,000; Weber County in WFRC MPO; UTA FrontRunner station present; all res_sf zones in scope). Chapter 3 overlay roster (FP / SA / TO / CO) = confirmed via Google snippet of Chapter 3 TOC; DGOD / ICO / HP / AIZ = partial (ordinance text not retrieved; inferred via Make Ogden 2023 draft and city landmarks/airport context). 3 claims remained unverifiable under amlegal_403: exact C-1/C-2/C-3/M-1/M-2 dimensional tables, R-3/R-4 split details, current WFRC SAP certification status. Thresholds: 43/46 = 93.5% supported → verification status partial. No claims contradicted.
narrative_refzoning/narratives/ogden-ut/fleet-20260419T210455-15.json

Other cities in this state