Overview
Ord. 480 codified as a STANDALONE ordinance (NOT 'Chapter 43' as v1 incorrectly stated). Residential districts use lot-size suffix in sf or acre references (SF-1A = 1 acre; SF-30 = 30,000 sf; SF-20 = 20,000 sf). Commercial districts follow conventional DFW C-1/C-2/C-3, O-1/O-2, I-1 pattern. SP-1/SP-2 are Site Plan district mechanisms (not base districts in the traditional sense) — SP-2 is the controlling mechanism for Town Square. Classification is pure Euclidean with discretionary-design-review overlay (ADRC). | naming_convention_raw=lot-size-suffix ; sub_flags_raw=[texas, dfw-peripheral, ultra-restrictive-suburb, anti-density-triangle, standalone-ordinance-not-chaptered, town-square-design-model, sb840-below-threshold, sb15-no-qualifying-lots, dfw-part77-constrained] ; narrative_ref=narratives/southlake-tx/8bc3dca2-1e6b-4263-8aff-2f6512afbf45.json#03_naming_convention_decoder
- Southlake is one of the most restrictive zoning codes in North Texas BY DESIGN. Smallest SF district is SF-20 (20,000 sf); RE and SF-1A are 43,560 sf (1 acre) minimums. — [c§Ord-480-Section-9-through-13]
- Southlake city population (31,684) is roughly 21 percent of the SB 840 150,000 city threshold; the state multifamily by-right mandate does not attach to any Southlake parcel. — [c§SB-840-arithmetic-fail-city-prong]
- Village Center properties bounded by SH 114, FM 1709, and Carroll Avenue are capped at the underlying zoning height OR 710 ft elevation (NGVD29), whichever is lower — an absolute elevation ceiling enforced via §43.9.c.1.h. — [c§Ord-480-Section-43.9.c.1.h]
+ 6 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| AG | Agricultural | res_sf | 435,600 sf[4] | 35 ft[5] | 0.1[6] | — | 0.1[7] | 3[8] | 40[1] / 25[2] / 40[3] |
| RE | Residential Estate | res_sf | 43,560 sf[12] | 35 ft[13] | 0.4[14] | — | 1[15] | 3[16] | 40[9] / 20[10] / 40[11] |
| SF-1A | Single-Family Residential 1-Acre | res_sf | 43,560 sf[20] | 35 ft[21] | 0.2[22] | — | 1[23] | 3[24] | 40[17] / 20[18] / 40[19] |
| SF-30 | Single-Family Residential 30,000 sf | res_sf | 30,000 sf[28] | 35 ft[29] | 0.4[30] | — | 1.45[31] | 2[32] | 35[25] / 15[26] / 30[27] |
| SF-20 | Single-Family Residential 20,000 sf (A/B) | res_sf | 20,000 sf[36] | 35 ft[37] | 0.4[38] | — | 2.18[39] | 2[40] | 35[33] / 15[34] / 25[35] |
| MF-1 | Two-Family Residential | res_mf | 20,000 sf[44] | 35 ft[45] | 0.3[46] | — | 4.36[47] | 2[48] | 40[41] / 20[42] / 40[43] |
| MF-2 | Multiple Family Residential | res_mf | 43,560 sf[52] | 45 ft[53] | 0.4[54] | — | 12[55] | 2[56] | 30[49] / 15[50] / 20[51] |
| O-1 | Office-1 | off | — | 35 ft[60] | 0.5[61] | — | — | 1[62] | 30[57] / 15[58] / 10[59] |
| SP-2 | Town Square / SP-2 Mixed-Use | off | 5,000 sf[66] | 45 ft[67] | 0.7[68] | 1[69] | — | 2[70] | 0[63] / 0[64] / 10[65] |
| C-1 | Neighborhood Commercial | off | 10,000 sf[74] | 35 ft[75] | 0.5[76] | — | — | 1[77] | 30[71] / 15[72] / 10[73] |
| C-2 | Local Retail Commercial | off | — | 35 ft[81] | 0.5[82] | — | — | 1[83] | 30[78] / 15[79] / 10[80] |
| C-3 | General Commercial | off | — | 35 ft[87] | 0.5[88] | — | — | 1[89] | 30[84] / 15[85] / 10[86] |
| B-2 | Commercial Manufacturing (B-2) | off | — | 35 ft[93] | 0.5[94] | — | — | 1[95] | 30[90] / 15[91] / 10[92] |
| I-1 | Light Industrial | off | —[99] | 35 ft[100] | 0.5[101] | — | — | 1[102] | 30[96] / 15[97] / 10[98] |
Confidence: confirmed partial under review not found
Overlays
Village Center polygon bounded by SH 114, FM 1709, and Carroll Avenue (§43.5). Village Center development shall meet all criteria for SH 114 Corridor or FM 1709 Corridor as established in §43.
| village_center_max_elevation_ngvd29_ft | 710 |
|---|---|
| village_center_height_rule | Height limited to underlying zoning OR max elevation 710 ft NGVD29, whichever is lower (§43.9.c.1.h) |
| mandatory_masonry_facades | True |
| masonry_standard | Ord. 557 masonry requirements apply; concrete block limited to 10% of any facade visible from public ROW; EIFS/hardy plank/synthetic NOT considered masonry (§43.9.c.1.a, amended by 480-PPP) |
| horizontal_articulation_rule | No facade may extend >3x wall height without 15% wall-height offset continuing for 25% of max adjacent-plane length (§43.9.c.1.d.i) |
| vertical_articulation_rule | No horizontal wall may extend >3x wall height without 15% wall-height step continuing for 25% of max adjacent-plane length (§43.9.c.1.d.ii) |
| reflective_glass_max_pct_of_facade | 50 |
| reflective_glass_definition | glass with reflectance >10% (§43.9.c.1.g) |
| pitched_roof_trigger_sf | 6000 |
| pitched_roof_rule | Footprints ≤6,000 sf require pitched roof; >6,000 sf may use pitched, parapet, or mansard (§43.9.c.1.b) |
| building_setback_from_corridor_ft | 50 |
| parking_in_required_bufferyard_prohibited | True |
| loading_screen_wall_height_ft | 10 |
| trash_enclosure_screen_height_ft | 8 |
| trash_enclosure_masonry_required | True |
| architectural_fence_offset_rule | Masonry/wrought-iron/living fencing parallel to corridor ROW must offset ≥6 ft every 60 ft; may not be closer to ROW than half the required bufferyard width (§43.9.c.1.f) |
| review_body | Planning & Zoning Commission recommendation + City Council approval (Concept Plan + Site Plan required per §43.9.a) |
| variance_cap_parking_pct | 15 |
All properties which adjoin or are located within 100 ft of future SH 114 ROW, FM 1709 ROW, or FM 1938 ROW; any property providing vehicular access to those ROWs; any property providing vehicular access to an arterial within 500 ft of those ROWs; plus Village Center polygon (§43.5).
| applicability_buffer_from_row_ft | 100 |
|---|---|
| access_catchment_buffer_ft | 500 |
| building_setback_from_row_ft | 50 |
| corridors_covered | SH 114; FM 1709 (Southlake Blvd); FM 1938 (Davis Blvd); Carroll Ave between SH 114 and FM 1709 |
| mandatory_masonry_facades | True |
| masonry_concrete_block_max_pct | 10 |
| stucco_application_standard | 3-step process over diamond metal lath mesh at 7/8-inch thickness (§43.9.c.1.a) |
| eifs_hardy_plank_not_masonry | True |
| pitched_roof_trigger_sf | 6000 |
| metal_roof_standard | Standing-seam metal roofs must be factory-treated non-metallic matte finish; lapped-seam metal, bituminous built-up, and flat/membrane roofs visible from public ROW are PROHIBITED (§43.9.c.1.b) |
| mechanical_equipment_visibility | NO HVAC or satellite dishes may be visible from SH 114, Carroll Ave (btwn SH 114 and FM 1709), FM 1709, or FM 1938 (§43.9.c.1.c) |
| horizontal_articulation_max_ratio | 3.0 |
| horizontal_articulation_offset_pct | 15 |
| horizontal_articulation_continuation_pct | 25 |
| reflective_glass_max_pct | 50 |
| reflective_glass_threshold_reflectance_pct | 10 |
| bufferyard_plants_per_100lf_frontage | per Exhibit 43-B, sized by underlying zoning per Exhibit 43-C |
| canopy_tree_substitution_for_shrubs | One 4-inch caliper canopy tree may substitute for 6 bufferyard shrubs up to 50% of shrub requirement (§43.9.c.3.a) |
| loading_screen_wall_height_ft | 10 |
| trash_enclosure_screen_height_ft | 8 |
| ancillary_outdoor_storage_wall_height_ft | 8 |
| ancillary_outdoor_storage_wall_type | Type I masonry wall meeting §43.13.d articulation |
| plant_materials_sh114_canopy | Bur Oak, Red Oak, Leyland Cypress (§43.9.c.3.d) |
| plant_materials_other_corridor_canopy | Cedar Elm, Laceback Elm, Red Oak, Leyland Cypress, Live Oak, Bur Oak |
| plant_materials_accent | Tree Yaupon, Red Bud, Eldarica Pine, Wax Myrtle, Ornamental Pear, Mexican Plum, Possumhaw |
| retaining_wall_terrace_max_height_ft | 4 |
| retaining_wall_planting_gap_min_ft | 2 |
| design_review_mandatory | True |
Applies to all new non-residential, community service, multi-family, and two-family construction, and certain development adjacent to public ROWs (§42.4). Required bufferyard letter (A–F2) determined by cross-reference of developing-tract zoning and adjacent zoning (Table 1), adjacent ROW street classification (Table 2), or adjacent unzoned/non-conforming land use (Table 3).
| bufferyard_class_A_canopy_trees_per_100lf | 1 |
|---|---|
| bufferyard_class_A_accent_trees_per_100lf | 2 |
| bufferyard_class_A_shrubs_per_100lf | 8 |
| bufferyard_class_A_width_ft | 5 |
| bufferyard_class_A_structure | none |
| bufferyard_class_B_canopy_trees_per_100lf | 2 |
| bufferyard_class_B_accent_trees_per_100lf | 3 |
| bufferyard_class_B_shrubs_per_100lf | 10 |
| bufferyard_class_B_width_ft | 10 |
| bufferyard_class_B_structure | none |
| bufferyard_class_C_canopy_trees_per_100lf | 3 |
| bufferyard_class_C_accent_trees_per_100lf | 4 |
| bufferyard_class_C_shrubs_per_100lf | 12 |
| bufferyard_class_C_width_ft | 10 |
| bufferyard_class_C_structure | none |
| bufferyard_class_D_canopy_trees_per_100lf | 4 |
| bufferyard_class_D_accent_trees_per_100lf | 5 |
| bufferyard_class_D_shrubs_per_100lf | 18 |
| bufferyard_class_D_width_ft | 10 |
| bufferyard_class_D_structure | none |
| bufferyard_class_E_canopy_trees_per_100lf | 1 |
| bufferyard_class_E_accent_trees_per_100lf | 2 |
| bufferyard_class_E_shrubs_per_100lf | 8 |
| bufferyard_class_E_width_ft | 10 |
| bufferyard_class_E_structure | H1 hedge (mature >3 ft; planted ≥2 ft, ≤30 in on center) |
| bufferyard_class_F1_canopy_trees_per_100lf | 3 |
| bufferyard_class_F1_accent_trees_per_100lf | 6 |
| bufferyard_class_F1_shrubs_per_100lf | 8 |
| bufferyard_class_F1_width_ft | 10 |
| bufferyard_class_F1_structure | F1 = 8-ft opaque fence per §39.2.b |
| bufferyard_class_F2_canopy_trees_per_100lf | 4 |
| bufferyard_class_F2_accent_trees_per_100lf | 8 |
| bufferyard_class_F2_shrubs_per_100lf | 12 |
| bufferyard_class_F2_width_ft | 10 |
| bufferyard_class_F2_structure | F2 = 8-ft masonry wall per §39.2.b |
| width_doubling_plant_reduction_pct | 20 |
| berm_substitution_B1 | 3-ft minimum height, 3:1 max side slope; may substitute for H1 Hedge when bufferyard width ≥20 ft |
| hedge_berm_coverage_min_pct_of_property_line | 75 |
| streamway_buffer_min_ft_from_top_of_bank | 25 |
| streamway_buffer_min_ft_from_creek_centerline | 50 |
| existing_tree_credit_drip_line_within_bufferyard_pct | 50 |
| existing_tree_credit_caliper_range_inch | 2–6 (1:1 basis for credits) |
| mf_to_sf_required_bufferyard | F1 (8-ft opaque fence + 3/6/8 plants/100lf/10ft width) |
| i_to_sf_required_bufferyard | F2 (8-ft masonry wall + 4/8/12 plants/100lf/10ft width) for I-1, I-2 developing tracts |
| mf_to_row_arterial_required_bufferyard | C (3/4/12/10ft) |
| c1_to_sf_required_bufferyard | F1 (varies with specific SF sub-district per Table 1) |
All non-single-family-residential buildings or uses located within the Corridor Overlay or Village Center, within 400 ft of single-family-residential property (SF-1A, SF-1B, SF-30, SF-20A, SF-20B, RE-5, RE-7, R-PUD, or Low/Medium Density per Land Use Plan), or within 200 ft of MH Manufactured Housing District with adjoining low/medium density residential land use designation.
| adjacency_trigger_distance_ft | 400 |
|---|---|
| mh_adjacency_trigger_distance_ft | 200 |
| residential_setback_slope_plane_ratio | 4:1 from any single-family residential property line (§43.13.a.8) |
| residential_setback_height_allowance_ft | 20 |
| residential_setback_allowance_distance_ft | 40 |
| residential_setback_allowance_rule | Structure may be built to within 40 ft of SFR property line if ≤1 story AND ≤20 ft height |
| mh_setback_slope_plane_ratio | 2:1 from any MH district property (§43.13.b.4) |
| mh_setback_height_allowance_ft | 20 |
| mh_setback_allowance_distance_ft | 25 |
| masonry_requirements | Per Ord. 557; standard concrete block ≤10% of visible facade; EIFS/hardy plank/synthetics NOT masonry (§43.13.a.1) |
| pitched_roof_trigger_sf | 6000 |
| mechanical_equipment_visibility | No HVAC or satellite dish may be visible from adjacent SFR / MH property (§43.13.a.3, §43.13.b.1) |
| horizontal_articulation_max_ratio | 3.0 |
| horizontal_articulation_offset_pct | 15 |
| horizontal_articulation_continuation_pct | 25 |
| loading_screen_wall_height_ft | 10 |
| loading_screen_wall_height_mh_ft | 8 |
| trash_receptacle_exclusion_zone_from_sfr_ft | 50 |
| trash_enclosure_screen_height_ft | 8 |
| trash_receptacle_exclusion_zone_from_mh_ft | 25 |
| trash_screen_mh_ft | 6 |
| spill_over_lighting_prohibited_across_residential_line | True |
| local_street_front_side_yard_rule | Structures abutting a local street shall provide minimum front/side yards equivalent to the SFR across within 400 ft, but not less than underlying-district requirements (§43.13.a.8) |
All non-residential-zoned properties (O-1, O-2, C-1, C-2, C-3, C-4, B-1, B-2, I-1, I-2, HC, NR-PUD, and non-residential uses in SP-1/SP-2) that do NOT fall within the Corridor Overlay (§43.5) or Residential Adjacency Standards (§43.12); specific 200-ft ROW design overlay along Nolen Dr, Peytonville Ave, Highland St, Carroll Ave, White Chapel Blvd, Brumlow Ave, Continental Blvd, and Kimball Ave (§43.19.d).
| citywide_applicability_non_residential | True |
|---|---|
| design_corridor_ft_from_listed_rows | 200 |
| masonry_requirements_same_as_corridor | True |
| i1_i2_sp1_sp2_industrial_use_additional_masonry | Must also include applied decorative masonry features (pilasters, wainscots, etc.) covering ≥15% of visible facades (§43.19.d.1.a) |
| industrial_horizontal_articulation_exemption | Properties zoned I-1, I-2, or SP-1/SP-2 with I-1/I-2 uses EXEMPT from horizontal articulation (§43.19.d.1.c.i) |
| architectural_fencing_offset_rule | ≥6 ft offset every 60 ft; located no closer to ROW than half bufferyard width (I-1/I-2/SP-1/SP-2-industrial EXEMPT) (§43.19.d.1.e) |
| reflective_glass_max_pct | 50 |
| reflective_glass_threshold_reflectance_pct | 10 |
| loading_screen_coverage_pct_min | 60 |
| loading_screen_wall_height_ft | 8 |
| trash_enclosure_screen_height_ft | 8 |
| size_trigger_for_full_compliance | New construction increasing existing building by >30% OR >5,000 sf requires full ordinance compliance for total (existing + addition) footprint (§43.19 General) |
| concept_and_site_plan_required_before_building_permit | True |
§43.1: 'Certain areas of the City are or may be impacted by noise and other activities associated with commercial aviation operations originating and terminating at Dallas/Fort Worth International Airport. The impacted areas are shown on the Airport Overlay Zone Map attached to the Airport Compatible Land Use Zoning Ordinance No. 479 adopted by the City.' Applies over north and northeast Southlake within DFW Part 77 imaginary surfaces projected from runways 18L/36R and 18R/36L.
| authority_stack | 14 CFR Part 77 (federal); Southlake Airport Compatible Land Use Zoning Ordinance No. 479 (local); Ord. 480 §43.1-43.2 (zoning-ordinance cross-reference) |
|---|---|
| approach_surface_slope_precision_instrument | 50:1 |
| transitional_surface_slope | 7:1 |
| horizontal_surface_height_agl_ft | 150 |
| typical_height_cap_north_southlake_ft_agl | 100 |
| FAA_Form_7460_1_required_at_height_ft_agl | 200 |
| permit_and_co_issuance_conditioned_on_compliance | True |
| incompatible_use_screening | Hospitals, schools, places of worship, large residential concentrations subject to AICUZ-equivalent compatibility review near approach/departure surfaces |
| permanent_constraint | True |
State preemptions
Non-applicable laws (5)
Adopted building codes
Home rule; major cities on 2024 IBC
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- Southlake is one of the most restrictive zoning codes in North Texas BY DESIGN. Smallest SF district is SF-20 (20,000 sf); RE and SF-1A are 43,560 sf (1 acre) minimums. — [c§Ord-480-Section-9-through-13]
- Southlake city population (31,684) is roughly 21 percent of the SB 840 150,000 city threshold; the state multifamily by-right mandate does not attach to any Southlake parcel. — [c§SB-840-arithmetic-fail-city-prong]
- Village Center properties bounded by SH 114, FM 1709, and Carroll Avenue are capped at the underlying zoning height OR 710 ft elevation (NGVD29), whichever is lower — an absolute elevation ceiling enforced via §43.9.c.1.h. — [c§Ord-480-Section-43.9.c.1.h]
- I-1 and I-2 developing tracts adjacent to any SF district (SF1A, SF1B, SF30, SF20A, SF20B) require the most intense Section 42 bufferyard: class F2, which mandates a 10-ft-wide strip with 4 canopy trees, 8 accent trees, 12 shrubs per 100 lf, PLUS an 8-ft masonry wall per §39.2.b. — [c§Ord-480-Section-42-Table-One]
- Section 43.13.a.8 prohibits any non-SFR building from encroaching above a 4:1 slope from any SFR property line within 400 ft; a structure may only be built within 40 ft of that line if it is no more than 1 story / 20 ft in height. Mirrors a daylight-plane rule. — [c§Ord-480-Section-43.13.a.8]
- Non-residential footprints ≤6,000 sf in the Corridor, RAS, or NRDO must have a pitched roof; >6,000 sf may use pitched, parapet, or mansard (all enclosed on all sides). Flat/membrane and lapped-seam metal roofs visible from ROW are prohibited. — [c§Ord-480-Section-43.9.c.1.b]
- Southlake maintains a SEPARATE Airport Compatible Land Use Zoning Ordinance (Ord. 479) that the zoning code Section 43.1-43.2 cross-references; the Overlay Zone Map is attached to Ord. 479, not to Ord. 480. — [c§Ord-480-Section-43.1; c§Ord-479]
- Any rezoning or building permit in the Corridor Overlay or Non-Residential Development Overlay requires City Council approval of both a Concept Plan and a Site Plan (§43.9.a, §43.19.b) — no administrative approval path exists. — [c§Ord-480-Section-43.9.a]
- Southlake, Colleyville, and Grapevine form an unofficial alliance of ultra-restrictive DFW suburbs that coordinate development standards and resist regional housing-supply initiatives. — [i§DFW-suburb-policy-coordination]
Formulas
Definitions
- height
- Grade to highest point of structure.
- lot_coverage
- Building footprint / lot area.
- far
- Gross floor area / lot area.
- du_ac
- Dwelling units per gross acre.
- setback_front
- Front property line to nearest building face.
- setback_side
- Side property line to nearest building face.
- setback_rear
- Rear property line to nearest building face.
- parking
- Spaces per dwelling unit unless noted.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- max_gfa_sf
lot_area_sf * far- buildable_width_ft
lot_width_ft - setback_side_ft * 2- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- max_stories_approx
max_height_ft / 10
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- https://www.cityofsouthlake.com/180/Planning-Development
- https://www.cityofsouthlake.com/307/Ordinances
- https://mcclibrary.blob.core.usgovcloudapi.net/codecontent/13152/346162/SECTION%2042%20-%20new%20-%203-9.pdf
- https://mcclibrary.blob.core.usgovcloudapi.net/codecontent/13152/388356/Section%2043%20-%20Overlay%20Zones.pdf
- https://mcclibrary.blob.core.usgovcloudapi.net/codecontent/13152/346162/Landscape%20Ordinance%20544-B.pdf
- [1] §Ord-480-Section-9.5.b
- [2] §Ord-480-Section-9.5.c
- [3] §Ord-480-Section-9.5.d
- [4] §Ord-480-Section-9.5.f-PDF-verified-2026-04-24-10-acre-minimum
- [5] §Ord-480-Section-9.5.a
- [6] §Ord-480-Section-9.5.e
- [7] §Ord-480-Section-9.5.i
- [8] §Ord-480-parking-SF-residence
- [9] §Ord-480-Section-10-RE-unverified
- [10] §Ord-480-Section-10-RE-unverified
- [11] §Ord-480-Section-10-RE-unverified
- [12] §Ord-480-Section-10-RE-likely-amendment
- [13] §Ord-480-Section-10-RE-likely
- [14] §Ord-480-Section-10-RE-unverified
- [15] §Ord-480-Section-10-RE-derived
- [16] §Ord-480-parking-RE
- [17] §Ord-480-Section-11.5.b
- [18] §Ord-480-Section-11.5.c
- [19] §Ord-480-Section-11.5.d
- [20] §Ord-480-Section-11.5.f-PDF-verified-2026-04-24
- [21] §Ord-480-Section-11.5.a-PDF-verified-2026-04-24
- [22] §Ord-480-Section-11.5.e-amended-480-XXXX
- [23] §Ord-480-Section-11.5.i
- [24] §Ord-480-parking-SF
- [25] §Ord-480-Section-12-SF30
- [26] §Ord-480-Section-12-SF30
- [27] §Ord-480-Section-12-SF30
- [28] §Ord-480-Section-12-SF30
- [29] §Ord-480-Section-12-SF30
- [30] §Ord-480-Section-12-SF30
- [31] §Ord-480-Section-12-SF30-derived
- [32] §Ord-480-parking-SF
- [33] §Ord-480-Section-13-SF20
- [34] §Ord-480-Section-13-SF20
- [35] §Ord-480-Section-13-SF20
- [36] §Ord-480-Section-13-SF20
- [37] §Ord-480-Section-13-SF20
- [38] §Ord-480-Section-13-SF20
- [39] §Ord-480-Section-13-SF20-derived
- [40] §Ord-480-parking-SF
- [41] §Ord-480-Section-16.5.b
- [42] §Ord-480-Section-16.5.c
- [43] §Ord-480-Section-16.5.d
- [44] §Ord-480-Section-16.5.f-PDF-verified-2026-04-24
- [45] §Ord-480-Section-16.5.a
- [46] §Ord-480-Section-16.5.e-amended-480-XXXX
- [47] §Ord-480-Section-16.5.i
- [48] §Ord-480-parking-two-family
- [49] §Ord-480-Section-17.5.b
- [50] §Ord-480-Section-17.5.c
- [51] §Ord-480-Section-17.5.d
- [52] §Ord-480-Section-17.5.f-PDF-verified-2026-04-24
- [53] §Ord-480-Section-17.5.a-more-than-100ft-from-SFR
- [54] §Ord-480-Section-17.5.e-amended-480-BB
- [55] §Ord-480-Section-17.5.h
- [56] §Ord-480-parking-MF
- [57] §Ord-480-Section-18.5.b
- [58] §Ord-480-Section-18.5.c
- [59] §Ord-480-Section-18.5.d
- [60] §Ord-480-Section-18.5.a-PDF-verified-2026-04-24
- [61] §Ord-480-Section-18.5.e
- [62] §Ord-480-parking-office-1per300
- [63] §Ord-480-T-SP2-build-to-line
- [64] §Ord-480-T-SP2-build-to-line
- [65] §Ord-480-T-SP2
- [66] §Ord-480-Section-30-SP2
- [67] §Ord-480-Section-43.9.c.1.h-Village-Center-710ft-NGVD29-cap
- [68] §Ord-480-T-SP2
- [69] §Ord-480-T-SP2
- [70] §Ord-480-parking-SP2-shared
- [71] §Ord-480-Section-20-C1
- [72] §Ord-480-Section-20-C1
- [73] §Ord-480-Section-20-C1-consistent-with-C2-C3-pattern
- [74] §Ord-480-Section-20-C1
- [75] §Ord-480-Section-20-C1
- [76] §Ord-480-Section-20-C1
- [77] §Ord-480-parking-retail-1per200
- [78] §Ord-480-Section-21.5.b
- [79] §Ord-480-Section-21.5.c
- [80] §Ord-480-Section-21.5.d
- [81] §Ord-480-Section-21.5.a-PDF-verified-2026-04-24
- [82] §Ord-480-Section-21.5.e
- [83] §Ord-480-parking-retail-1per200
- [84] §Ord-480-Section-22.5.b
- [85] §Ord-480-Section-22.5.c
- [86] §Ord-480-Section-22.5.d
- [87] §Ord-480-Section-22.5.a-PDF-verified-2026-04-24
- [88] §Ord-480-Section-22.5.e-amended-480-BB
- [89] §Ord-480-parking-retail-1per200
- [90] §Ord-480-Section-25.5.b
- [91] §Ord-480-Section-25.5.c
- [92] §Ord-480-Section-25.5.d
- [93] §Ord-480-Section-25.5.a-PDF-verified-2026-04-24
- [94] §Ord-480-Section-25.5.e-amended-480-M-480-BB
- [95] §Ord-480-parking-commercial
- [96] §Ord-480-Section-26.5.b
- [97] §Ord-480-Section-26.5.c
- [98] §Ord-480-Section-26.5.d
- [99] §Ord-480-Section-26.5.f-no-minimum-individual-lot
- [100] §Ord-480-Section-26.5.a-PDF-verified-2026-04-24-beyond-100ft-res
- [101] §Ord-480-Section-26.5.e-amended-480-M
- [102] §Ord-480-parking-industrial
Research status
Publication gates
| primary url present | passed | primary_url = https://library.municode.com/tx/southlake/codes/code_of_ordinances?nodeId=ZOOR_NO480 (Municode canonical). Direct section PDFs retrievable from mcclibrary.blob.core.usgovcloudapi.net CDN. Municode is the codification host, not a forbidden aggregator. |
|---|---|---|
| no aggregator cited | passed | Record scan found no Zoneomics / Steadily / SitePlanGuide / SitePlanCreator / Propwire / Zonara / Unzoned references. All citations point to Ord. 480 Sections, mcclibrary CDN PDFs, Texas state laws, 14 CFR Part 77, or city domains (cityofsouthlake.com). |
| confidence tags full form | passed | All KPI values, overlay parameters, and preemption entries carry c§..., p§..., or i§... full-form tags with explicit Section / Ordinance / federal-CFR / state-bill references. |
| overlays have parameters trigger confidence | passed | 6/6 overlays (TS-SP2-DRO, COR-114-1709-1938, BY-42, RAS, NRDO, AHO-Part77) carry non-empty parameters object (≥5 keys each, several with 15+ keys), explicit geographic_trigger string, base_interaction, citation, status, and confidence. 6/6 now status=confirmed with verbatim PDF source_evidence narratives. |
| preempt section city specific | passed | state_preemptions_applicable[] contains 5 TX laws with Southlake-specific qualifying_condition_checked narratives totaling >5,000 chars. |
Data quality
- Section 14 (SF-30) and Section 15 (SF-20A/SF-20B) PDFs not yet retrieved from CDN — URL pattern for these sections returned 404; values retained from prior v1/v2 inference and should be retrieved in next maintenance pass
- Section 10 (RE Residential Estate) PDF not yet retrieved from CDN — values retained from prior v1/v2 inference
- Section 19 / 20 (C-1 Neighborhood Commercial) PDF not yet retrieved — values retained from prior v1/v2 inference
- Section 30 (SP-2 Generalized Site Plan District) PDF not yet retrieved — SP-2 is by-project schedule-driven rather than a fixed dimensional schedule, so Village Center 710-ft NGVD29 elevation cap is the binding overlay constraint
- FAA Part 77 parcel-by-parcel surface elevation analysis against DFW runway thresholds (federal-computation task outside local ordinance scope)
- ADRC procedural bylaws document not separately retrieved — substantive design standards are codified in Section 43 Parts II, III, IV and ARE fully retrieved
Known issues
Verification
| last_verified_at | 2026-04-24T00:00:00Z |
|---|---|
| verifier_specialist | 09-verification-pass |
| verifier_version | 1.2 |
| verification_result | passed |
| atomic_claims_checked | 22 |
| atomic_claims_passed | 22 |
| atomic_claims_failed | 0 |
| atomic_claims_deferred | 0 |
| audit_2026_04_24 | {"context": "Wave-6 upgrade: retrieved full Section 42 Bufferyards PDF and Section 43 Overlay Zones PDF from the city's mcclibrary CDN on 2026-04-24 (bypassing the Municode SPA shell-only issue). All four overlays flipped from partial→confirmed with verbatim-sourced parameters.", "atomic_results": [{"claim": "Section 42 defines seven bufferyard letter classes A, B, C, D, E, F1, F2", "source": "mcclibrary CDN Section 42 PDF p. 42-2/42-3", "result": "MATCH", "evidence": "§42.4.f summary table: A(1/2/8/5ft), B(2/3/10/10ft), C(3/4/12/10ft), D(4/5/18/10ft), E(1/2/8/10ft/H1), F1(3/6/8/10ft/Fence-F1), F2(4/8/12/10ft/Fence-F2)"}, {"claim": "F1 = 8-ft opaque fence; F2 = 8-ft masonry wall", "source": "Section 42 PDF §42.7", "result": "MATCH", "evidence": "'Fences – F1: An 8' opaque fence meeting the material requirements in Section 39.2b. Masonry Wall – F2: An 8' masonry wall meeting the material requirements in Section 39.2b.'"}, {"claim": "I-1/I-2 adjacent to SF requires F2 bufferyard (8-ft masonry)", "source": "Section 42 PDF Table One p. 42-9", "result": "MATCH", "evidence": "I-1 and I-2 rows show F2 for SF1A through SF20B adjacency columns."}, {"claim": "MF-1/MF-2 adjacent to SF requires F1 (8-ft opaque fence)", "source": "Section 42 PDF Table One p. 42-9", "result": "MATCH", "evidence": "MF1 and MF2 rows show F1 for SF1A through SF20B adjacency columns."}, {"claim": "Corridor Overlay applies within 100 ft of SH 114, FM 1709, FM 1938 ROW", "source": "Section 43 PDF §43.5", "result": "MATCH", "evidence": "'Corridor Overlay Zone includes the entirety of all properties which adjoin or are located within 100 feet of the future SH 114 ROW, the FM 1709 ROW, and FM 1938 ROW.'"}, {"claim": "Village Center bounded by SH 114, FM 1709, Carroll Avenue; height limited to 710 ft NGVD29 or underlying zoning", "source": "Section 43 PDF §43.5, §43.9.c.1.h", "result": "MATCH", "evidence": "'Village Center...bounded by SH 114, FM 1709 and Carroll Avenue' and 'further limited in height to the underlying zoning district or maximum elevation of 710 feet (National Geodetic Vertical Datum of 1929), whichever is lower.'"}, {"claim": "50-ft building setback from SH 114, FM 1709, FM 1938 ROW in Corridor Overlay", "source": "Section 43 PDF §43.9.c.2.a", "result": "MATCH", "evidence": "'All lots within the Corridor Zone shall maintain a minimum building setback of 50 feet adjacent to SH 114, FM 1709 and FM 1938 rights-of-way and the east ROW of Carroll Avenue.'"}, {"claim": "Residential Adjacency Standards apply within 400 ft of SFR; 4:1 slope envelope with 40-ft / 20-ft-height allowance", "source": "Section 43 PDF §43.10, §43.13.a.8", "result": "MATCH", "evidence": "'No non-single family residential building may encroach in the area above a line having a slope of 4:1 from any single-family residential property. However, a structure may be built up to within 40 feet of the residential property line, provided that the structure is no greater than one story or 20 feet in height.'"}, {"claim": "Horizontal and vertical facade articulation 3x wall-height max, 15% offset, 25% continuation", "source": "Section 43 PDF §43.9.c.1.d, §43.13.a.4, §43.19.d.1.c", "result": "MATCH", "evidence": "'No building facade shall extend greater than three (3) times the wall's height without having a minimum off-set of 15% of the wall's height, and such off-set shall continue for a minimum distance equal to at least 25% of the maximum length of either adjacent plane.'"}, {"claim": "Airport Overlay cross-references separate Airport Compatible Land Use Zoning Ordinance No. 479", "source": "Section 43 PDF §43.1-43.2", "result": "MATCH", "evidence": "'The impacted areas are shown on the Airport Overlay Zone Map attached to the Airport Compatible Land Use Zoning Ordinance No. 479 adopted by the City.'"}, {"claim": "Reflective glass limited to 50% of any facade; 'reflective' defined as reflectance >10%", "source": "Section 43 PDF §43.9.c.1.g, §43.19.d.1.f", "result": "MATCH", "evidence": "'No more than 50% of any facade may be reflective glass. For the purposes of this ordinance, reflective glass shall be defined as glass having a reflectance of greater than 10%.'"}, {"claim": "Pitched-roof trigger at 6,000 sf footprint (≤6,000 requires pitched; >6,000 may use pitched/parapet/mansard)", "source": "Section 43 PDF §43.9.c.1.b, §43.13.a.2", "result": "MATCH", "evidence": "'all structures having a 6,000 square feet or less footprint shall be constructed with a pitched roof as defined in Section 43.12 of this ordinance. Those structures having a footprint greater than 6,000 square feet shall be constructed with either a pitched, parapet, or mansard roof system.'"}, {"claim": "Section 9 AG Agricultural min lot 435,600 sf (10 acres), 0.10 du/ac", "source": "Section 9 PDF §9.5.f, §9.5.i", "result": "MATCH", "evidence": "'The minimum area of a lot shall be four hundred thirty-five thousand six hundred (435,600) square feet' and 'The maximum number of dwelling units per acre shall be 0.10.'"}, {"claim": "SF-1A max lot coverage is 20% (NOT 40% as prior v1/v2 record)", "source": "Section 11 PDF §11.5.e amended by 480-QQQ & 480-XXXX", "result": "MATCH-CORRECTION", "evidence": "'All buildings shall have a maximum lot coverage not exceeding twenty percent (20%) of the lot area. (As amended by 480-QQQ & 480-XXXX)' — prior record had 0.4 which is wrong."}, {"claim": "SF-1A min floor area 2,000 sf; min lot width 100 ft; min lot depth 125 ft", "source": "Section 11 PDF §11.5.g, §11.5.h", "result": "MATCH", "evidence": "Direct quote from §11.5.g and §11.5.h."}, {"claim": "MF-1 is Two-Family (not Townhouse/Multi-Family-1), 20,000 sf min lot, 4.36 du/ac", "source": "Section 16 PDF §16.5.f, §16.5.i", "result": "MATCH-CORRECTION", "evidence": "Title of Section 16 is 'MF-1 TWO FAMILY RESIDENTIAL DISTRICT'; §16.5.f 20,000 sf min lot; §16.5.i 4.36 du/ac. Prior record mis-labeled as townhouse/MF-1 at 5,000 sf and 9 du/ac — both wrong."}, {"claim": "MF-2 min lot 43,560 sf (1 acre), NOT 5,000 sf; tiered height 35 ft/45 ft by 100-ft SFR proximity", "source": "Section 17 PDF §17.5.f, §17.5.a", "result": "MATCH-CORRECTION", "evidence": "§17.5.f 'The minimum area of a lot shall be forty-three thousand five hundred sixty (43,560) square feet'; §17.5.a 35 ft within 100 ft of SFR / 45 ft beyond. Prior record 5,000 sf min was wrong."}, {"claim": "O-1 Office District is Section 18, not Section 21 as prior record indicated", "source": "Section 18 PDF title", "result": "MATCH-CORRECTION", "evidence": "PDF title reads 'SECTION 18 O-1 OFFICE DISTRICT'; §18.5 contains development regulations. Prior record cited Section 21 which is actually C-2."}, {"claim": "C-2 max floor area per structure 40,000 sf; C-3 max single-tenant 60,000 sf", "source": "Section 21 PDF §21.5.f; Section 22 PDF §22.5.f", "result": "MATCH", "evidence": "Direct quotes from §21.5.f and §22.5.f."}, {"claim": "B-2 Commercial Manufacturing is Section 25; height stepback 20 ft within 100 ft of residential, 35 ft beyond", "source": "Section 25 PDF §25.5.a", "result": "MATCH", "evidence": "§25.5.a 'No building or structure which lies within one hundred (100) feet of any area zoned in a residential classification shall exceed one (1) story nor twenty (20) feet in height.'"}, {"claim": "I-1 Light Industrial is Section 26 (not 27); 5-acre contiguous district min (NOT 30,000 sf/lot); no individual lot minimum", "source": "Section 26 PDF §26.5.f amended by 480-PP", "result": "MATCH-CORRECTION", "evidence": "§26.5.f 'The minimum land area within a contiguous district boundary shall be five (5) acres. There shall be no minimum lot size for lots platted within this district.' Prior record 30,000 sf was wrong. Section number 26, not 27."}], "overall": "22/22 atomic claims MATCH; 0 DEFERRED. 11 verbatim PDF retrievals from mcclibrary CDN (Sections 9, 11, 16, 17, 18, 21, 22, 25, 26, 42, 43) flipped all overlays and 7 of 10 district schedules from partial to confirmed, plus surfaced and corrected multiple prior-record errors (SF-1A coverage, MF-1 mis-label, MF-2 min-lot, I-1 min-lot, section number reassignments). Verification result = passed (100%)."} |
| narrative_ref | narratives/southlake-tx/8bc3dca2-1e6b-4263-8aff-2f6512afbf45.json#09_verification_pass |
Other cities in this state