- R-2 interior side setback scales 7.5 ft per story: first story = 7.5 ft; two-story = 15 ft cumulative from property line (§Table 11-2A-4, ZOA 2025-0001).
- C-G district has NO minimum setback requirements but buildings may not encroach into required street landscape buffers (§11-2B-3).
- R-40 multifamily residential buildings must provide minimum 10 ft setback per §11-4-3-27B.1 unless Building Code requires more.
+ 7 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| R-2 | Low Density Residential | res_sf | 12,000 sf[4] | 35 ft[5] | — | — | — | [{'variant': '1-2BR SF detached', 'value': 2}, {'variant': '3-4BR SF detached', 'value': 4}, {'variant': '5BR+ SF detached', 'value': 6}][6] | 20[1] / 7.5[2] / 15[3] |
| R-4 | Medium Low Density Residential | res_sf | 8,000 sf[10] | —[11] | — | — | — | [{'variant': '1-2BR SF detached', 'value': 2}, {'variant': '3-4BR SF detached', 'value': 4}, {'variant': '5BR+ SF detached', 'value': 6}][12] | —[7] / —[8] / —[9] |
| R-8 | Medium Density Residential | res_sf | 4,000 sf[16] | —[17] | — | — | — | [{'variant': '1-2BR SF/duplex/townhouse', 'value': 2}, {'variant': '3-4BR SF/duplex/townhouse', 'value': 4}, {'variant': '5BR+ SF/duplex/townhouse', 'value': 6}][18] | —[13] / —[14] / —[15] |
| R-15 | Medium High Density Residential | res_mf | 2,500 sf[22] | —[23] | — | — | [{'variant': 'min', 'value': 8}, {'variant': 'max', 'value': 12}][24] | [{'variant': 'studio MF', 'value': 1}, {'variant': '1BR MF', 'value': 1.5}, {'variant': '2BR MF', 'value': 2}, {'variant': '3BR MF', 'value': 3}, {'variant': '4BR+ MF', 'value': 3}][25] | —[19] / —[20] / —[21] |
| R-40 | High Density Residential | res_mf | —[29] | —[30] | — | — | — | [{'variant': 'studio MF', 'value': 1}, {'variant': '1BR MF', 'value': 1.5}, {'variant': '2BR MF', 'value': 2}, {'variant': '3BR MF', 'value': 3}, {'variant': '4BR+ MF', 'value': 3}][31] | 10[26] / —[27] / —[28] |
| C-N | Neighborhood Business District | com | — | —[32] | — | — | — | — | — / — / — |
| C-C | Community Business District | com | — | —[33] | — | — | — | — | — / — / — |
| C-G | General Retail and Service Commercial District | com | — | 65 ft[37] | — | — | — | — | —[34] / —[35] / —[36] |
| L-O | Limited Office District | off | — | —[38] | — | — | — | — | — / — / — |
| M-E | Mixed Employment District | mu | — | —[39] | — | — | — | — | — / — / — |
| H-E | High Density Employment District | mu | — | —[40] | — | — | — | — | — / — / — |
| I-L | Light Industrial District | ind | —[44] | 50 ft[45] | — | — | — | — | 35[41] / —[42] / —[43] |
| I-H | Heavy Industrial District | ind | — | —[46] | — | — | — | — | — / — / — |
| TN-R | Traditional Neighborhood Residential | res_th | 2,000 sf[48] | —[49] | — | — | [{'variant': 'gross', 'value': 8.06}, {'variant': 'net', 'value': 14.23}][50] | — | —[47] / — / — |
| TN-C | Traditional Neighborhood Center | mu | — | —[51] | — | — | — | — | — / — / — |
| O-T | Old Town District | cbd | — | —[52] | — | — | — | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Applies to any parcel within a FEMA-designated Special Flood Hazard Area (Zone AE, AO, A) along Boise River tributaries, Five Mile Creek, Ten Mile Creek, Eight Mile Lateral, and other drainageways in Meridian.
| ffa_freeboard_min_ft | 1 |
|---|---|
| fill_placement_restricted | True |
| irrigation_lateral_piping_required | True |
Parcels within the Boise Airport Part 77 surfaces and FAA airspace notification area. Meridian's northern and central areas lie within the BOI influence area (~10 miles west of BOI).
| height_limit_note | Graduated height limits based on FAA Part 77 surface at specific coordinates; varies by location within city |
|---|---|
| faa_notification_required | True |
Parcels within designated wellhead protection zones for Meridian's municipal water supply wells. Restricts certain land uses and underground storage.
| hazardous_materials_restricted | True |
|---|---|
| underground_storage_tanks_restricted | True |
Applies to any parcel subject to a recorded Development Agreement (DA) per Idaho Code §67-6511A. A significant portion of Meridian's annexed land is under DA.
| custom_standards_may_override_base_zone | True |
|---|---|
| da_runs_with_land | True |
| modification_requires_city_council_approval | True |
State preemptions
Non-applicable laws (2)
Adopted building codes
Statewide; extensive NEC amendments
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- R-2 interior side setback scales 7.5 ft per story: first story = 7.5 ft; two-story = 15 ft cumulative from property line (§Table 11-2A-4, ZOA 2025-0001).
- C-G district has NO minimum setback requirements but buildings may not encroach into required street landscape buffers (§11-2B-3).
- R-40 multifamily residential buildings must provide minimum 10 ft setback per §11-4-3-27B.1 unless Building Code requires more.
- Education facilities are allowed maximum 50 ft height in ALL residential districts as an exception to base district height limits per §11-2A-3E.3.
- Multifamily parking requires covered spaces: 1BR = 1 covered of 1.5 total; 2BR = 1 covered of 2 total; 3BR = 1 covered of 3 total; 4BR+ = 2 covered of 3 total (Table 11-3C-6).
- SF detached parking scales by bedroom count: 1-2BR = 2 spaces (1 enclosed garage + pad option); 3-4BR = 4 spaces (2 enclosed); 5+BR = 6 spaces (3 enclosed) per Table 11-3C-6.
- Municode SPA blocks scripted fetch; dimensional tables for R-4 through R-40 and all commercial/industrial districts require JavaScript rendering. Full dimensional tables for these districts are not_found in this record — a Municode-bypass retrieval pass is needed.
- Street buffers in Meridian are measured from back of curb for landscaping width per §11-3B-7C; local streets do not require landscape buffers in residential districts.
- SB 1354, SB 1352, and HB 707 (all effective July 1, 2026) impose new by-right requirements for ADUs, starter-home subdivisions (min lot 2,000 sf), and lot splits that will require Meridian UDC amendments.
- TEMPLATE-BLEED CORRECTED: Prior v1 record used fabricated district codes SF-5/SF-7.5/SF-10/MF-12/MF-18/MF-25 with identical fabricated values (lot_coverage=0.5, far=0.5, parking=2 for all). These codes do not exist in Meridian UDC. Actual codes are R-2/R-4/R-8/R-15/R-40 (residential), C-N/C-C/C-G/L-O/M-E/H-E (commercial), I-L/I-H (industrial), TN-R/TN-C/O-T (special).
Formulas
Definitions
- height
- Grade to highest point of structure.
- lot_coverage
- Building footprint divided by lot area.
- far
- Gross floor area divided by lot area.
- du_ac
- Dwelling units per gross acre.
- setback_front
- Front property line (or back of sidewalk) to nearest building face.
- setback_side
- Side property line to nearest building face.
- setback_rear
- Rear property line to nearest building face.
- parking
- Spaces per dwelling unit unless noted.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- max_gfa_sf
lot_area_sf * far- buildable_width_ft
lot_width_ft - setback_side_ft * 2- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- max_stories_approx
max_height_ft / 10
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §Table 11-2A-4
- [2] §Table 11-2A-4
- [3] §Table 11-2A-4
- [4] §Table 11-2A-4
- [5] §Table 11-2A-4
- [6] §Table 11-3C-6
- [7] n
- [8] n
- [9] n
- [10] i§11-2A-5/Table 11-2A-5
- [11] n
- [12] §Table 11-3C-6
- [13] n
- [14] n
- [15] n
- [16] i§11-2A-6/Table 11-2A-6
- [17] n
- [18] §Table 11-3C-6
- [19] n
- [20] n
- [21] n
- [22] i§11-2A-7/Table 11-2A-7
- [23] n
- [24] §11-2A-7
- [25] §Table 11-3C-6
- [26] §11-4-3-27B.1
- [27] n
- [28] n
- [29] n
- [30] n
- [31] §Table 11-3C-6
- [32] n
- [33] n
- [34] §11-2B-3
- [35] §11-2B-3
- [36] §11-2B-3
- [37] §11-2B-3A.3
- [38] n
- [39] n
- [40] n
- [41] §11-2C-3
- [42] n
- [43] n
- [44] n
- [45] §11-2C-3
- [46] n
- [47] n
- [48] i§11-2D-3/Table 11-2D-6
- [49] n
- [50] §11-2D-3
- [51] n
- [52] n
Research status
Publication gates
| primary url present | passed | source.primary_url = https://library.municode.com/id/meridian/codes/code_of_ordinances?nodeId=TIT11UNDECO (official Municode-hosted Meridian UDC Title 11); not an aggregator |
|---|---|---|
| no aggregator cited | passed | scan clean — all citations reference Title 11 section/table refs, Idaho Code section refs, or Meridian city ordinance numbers; no Zoneomics/Steadily/SitePlanGuide or other aggregator domains cited |
| confidence tags full form | failed | R-2 confirmed fields have c§Table 11-2A-4 citations; C-G/I-L confirmed fields have c§11-2B-3/c§11-2C-3 citations. However, 9 of 16 districts have dimensional fields (max_height_ft, setback_front_ft, setback_side_ft, setback_rear_ft) recorded as not_found (c=n) due to Municode SPA block preventing retrieval of Tables 11-2A-5 through 11-2A-8, 11-2B-1 through 11-2B-6, 11-2C-2, 11-2D-5, O-T section. Partial fields carry i§ citations from staff report practice ranges. Gate fails until full dimensional tables retrieved. |
| overlays have parameters trigger confidence | passed | 4 overlays documented: FP-O (c confidence, params + trigger), AIA-BOI (p confidence, params + trigger + note), WHP-O (p confidence, params + trigger + note), DA-O (c confidence, params + trigger). All have non-empty params object, explicit trigger string, status, and ordinance citation. |
| preempt section city specific | passed | 10 Idaho preemption laws evaluated with Meridian-specific qualifying_condition_checked: population 125,400 used for threshold-gated laws (SB 1354, SB 1352, HB 707 require pop ≥ 10,000); Comprehensive Plan Res. 19-2179 cited for LLUPA framework; STR posture and HB 706 opt-in correctly recorded as false/not-confirmed per available sources. |
Data quality
- R-4 height, front/side/rear setbacks — requires Municode Table 11-2A-5
- R-8 frontage, height, front/side/rear setbacks — requires Municode Table 11-2A-6
- R-15 frontage, height, setbacks — requires Municode Table 11-2A-7
- R-40 min lot, frontage, height, setbacks — requires Municode Table 11-2A-8
- C-N, C-C, L-O, M-E, H-E all dimensional standards — requires Municode Tables 11-2B-1 through 11-2B-6
- I-H all dimensional standards — requires Municode Table 11-2C
- TN-C, O-T all dimensional standards — requires Municode Tables 11-2D-5 and O-T section