Overview
30-class Euclidean code adopted 1942 with 80+ years of accretion: 15 residential codes (R-A, R-1A, R-1, R-2A, R-2, G, HR, R-3, R-3A, R-3B, U-R, R-55A, R-55B, GR, AG), 2 office/research (AR, AR-1), 7 commercial (C-O, NC, LC, GC, SC, SM, SM-1), 2 industrial (LI, HI), and 2 mixed-use (KPMU 2014, NMU). Form-based-leaning sub-overlay applies in KPMU via mandatory design manual + LEED-tied height bonus.
- 30 zoning-district classes across 14 residential codes (AG, R-A, R-1A, R-1, R-2A, R-2, G, HR, R-3, R-3A, R-3B, U-R, R-55A, R-55B, GR), 2 office/research (AR, AR-1), 7 commercial (C-O, NC, LC, GC, SC, SM, SM-1), 2 industrial (LI, HI), and 2 mixed-use (KPMU 2014, NMU). Among the most fragmented residential typologies in the corpus — the result of 80+ years of incremental amendment since the 1942 base ordinance. [severity: high; citation: §165 Establishment of Districts (ecode360.com/11658599)]
- KPMU height bonus tied to LEED certification — uncommon mechanism that ties land-use entitlement to sustainability certification rather than to fee-in-lieu / affordability / public benefit. Worth flagging for underwriting: pro forma must value LEED capex as a height-bonus enabler, not just an operating-cost premium. [severity: medium; citation: §165 KPMU Design Standards (ecode360.com/29439667)]
- C-O Commercial Office FAR is expressed as inverse lot:gross-floor ratio (4:1, 3:1, 5:1) rather than a direct FAR cap — equates to FAR 0.25 / 0.333 / 0.20 respectively. Tier varies by use type and stories. Common in legacy mid-20th-century PA codes; adapt pro forma carefully (a quoted '4:1' here means 0.25 FAR, the inverse of how 4:1 is read in most modern codes). [severity: high; citation: §165 C-O — lot-area-to-gross-floor ratio (ecode360.com/11659233)]
+ 5 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| AG | Agricultural District | ag | — | — | — | — | — | — | — / — / — |
| R-A | Recreational Area District | spec | — | — | — | — | — | — | — / — / — |
| R-1A | Single-Family Residential R-1A | res_sf | — | — | — | — | — | — | — / — / — |
| R-1 | Single-Family Residential R-1 | res_sf | — | — | — | — | — | — | — / 10[1] / 10[2] |
| R-2A | Single-Family Residential R-2A | res_sf | — | — | — | — | — | — | — / — / — |
| R-2 | Single-Family Residential R-2 | res_mf | — | — | — | — | — | — | — / — / — |
| G | Garden Apartment G District | res_mf | — | — | — | — | — | — | — / — / — |
| HR | High-Rise Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| R-3 | R-3 Residential District | res_mf | 5,000 sf[3] | [{'variant': 'base', 'value': 35, 'citation': '§165-11 Art IV'}, {'variant': 'multifamily_with_yard_expansion', 'value': 50, 'citation': '§165 R-3 — multifamily may exceed 35 ft up to 50 ft, provided each yard widened/deepened 1 ft per ft of height above 35 ft (ecode360.com/11658806)'}] ft[4] | — | — | — | — | — / — / — |
| R-3A | R-3A Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| R-3B | R-3B Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| U-R | U-R Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| R-55A | R-55A Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| R-55B | R-55B Residential District | res_mf | — | — | — | — | — | — | — / — / — |
| GR | Garden Apartment GR District | res_mf | — | — | — | — | — | — | — / — / — |
| AR | Administrative and Research District | off | — | — | — | — | — | — | — / — / — |
| AR-1 | AR-1 Administrative and Research District | off | — | — | — | — | — | — | — / — / — |
| C-O | Commercial Office District | off | — | [{'variant': 'base', 'value': 35, 'citation': '§165 C-O — base max 35 ft / 3 stories (ecode360.com/11659233)'}, {'variant': 'with_yard_expansion', 'value': 65, 'citation': '§165 C-O — may rise to 65 ft if each yard widened/deepened 1 ft per ft above 35'}] ft | — | [{'variant': 'default_uses', 'value': 0.25, 'citation': '§165 C-O — 4 sf lot per 1 sf gross floor for permitted uses (ecode360.com/11659233)'}, {'variant': 'buildings_3_or_more_stories', 'value': 0.333, 'citation': '§165 C-O — 3:1 ratio for buildings 3+ stories'}, {'variant': 'certain_other_uses', 'value': 0.2, 'citation': '§165 C-O — 5:1 ratio for certain other uses'}][5] | — | — | — / — / — |
| NC | Neighborhood Commercial District | com | — | — | — | — | — | — | — / — / — |
| LC | Limited Commercial District | com | — | — | — | — | — | — | — / — / — |
| GC | General Commercial District | com | — | — | — | — | — | — | — / — / — |
| SC | Shopping Center District | com | — | — | — | — | — | — | — / — / — |
| SM | Suburban Metropolitan District | off | [{'variant': 'multi-building_lot', 'value': 261360, 'citation': '§165 SM — minimum lot area for multi-building lot is 6 acres (6 × 43,560 sf) (ecode360.com/11659379)'}] sf | — | — | — | — | — | — / — / — |
| SM-1 | Suburban Metropolitan-1 District | off | — | 75 ft[7] | — | — | — | — | —[6] / — / — |
| LI | Limited Industrial District | ind | — | — | — | — | — | — | — / — / — |
| HI | Heavy Industrial District | ind | — | — | — | — | — | — | — / — / — |
| KPMU | King of Prussia Mixed-Use District | mu | — | — | — | — | — | — | — / — / — |
| NMU | Neighborhood Mixed-Use District | mu | — | — | — | — | — | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
FEMA-mapped 100-year floodplain along Schuylkill River and tributaries traversing Upper Merion Township; supplementary Floodplain Ordinance (2016 amendment, umtownship.org Doc 706) controls
| items | Elevation requirements per FEMA / NFIP standards; Restrictions on fill, excavation, and dangerous materials in floodway; Floodproofing requirements for all new construction or substantial improvement |
|---|
Areas with slopes ≥15% (limited development) and ≥25% (severely restricted); plan submissions must delineate both thresholds
| items | Plan submission must show all areas with slopes ≥15% and ≥25%; Prevents inappropriate development; preserves existing vegetation and stable soil cover; Limits grading and earthwork on qualifying slopes |
|---|
Eligible underlying districts at applicant election; specific eligibility map not retrieved
| items | Open-space-preservation alternative to conventional subdivision; Allows reduced lot sizes in exchange for permanently preserved open space |
|---|
All development in KPMU base district
| items | Mandatory design-manual submission with land development plan; Demonstrates compliance with architectural articulation, building materials, integrated streetscape standards; Height bonus available for LEED-certified development (specific bonus value not retrieved); Promotes ground-floor retail / dining / personal service along main roads |
|---|
State preemptions
Non-applicable laws (1)
Adopted building codes
Most jurisdictions opt in
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-04-26 | retrieved at | research run |
| 2025-03-13 | last amended | ecode360.com/UP0975 'current through' header observed 2026-04-26 |
| 2014-09-22 | amendment effective | KPMU King of Prussia Mixed-Use District adopted (Ord. 2014; PlanPhilly coverage 2014-09-22) |
| 1974-11-18 | amendment effective | Article XXXII Floodplain Conservation District added |
| 1942-03-04 | adoption | Chapter 165 Zoning — original adoption by Board of Supervisors |
Quirks & notes
- 30 zoning-district classes across 14 residential codes (AG, R-A, R-1A, R-1, R-2A, R-2, G, HR, R-3, R-3A, R-3B, U-R, R-55A, R-55B, GR), 2 office/research (AR, AR-1), 7 commercial (C-O, NC, LC, GC, SC, SM, SM-1), 2 industrial (LI, HI), and 2 mixed-use (KPMU 2014, NMU). Among the most fragmented residential typologies in the corpus — the result of 80+ years of incremental amendment since the 1942 base ordinance. [severity: high; citation: §165 Establishment of Districts (ecode360.com/11658599)]
- KPMU height bonus tied to LEED certification — uncommon mechanism that ties land-use entitlement to sustainability certification rather than to fee-in-lieu / affordability / public benefit. Worth flagging for underwriting: pro forma must value LEED capex as a height-bonus enabler, not just an operating-cost premium. [severity: medium; citation: §165 KPMU Design Standards (ecode360.com/29439667)]
- C-O Commercial Office FAR is expressed as inverse lot:gross-floor ratio (4:1, 3:1, 5:1) rather than a direct FAR cap — equates to FAR 0.25 / 0.333 / 0.20 respectively. Tier varies by use type and stories. Common in legacy mid-20th-century PA codes; adapt pro forma carefully (a quoted '4:1' here means 0.25 FAR, the inverse of how 4:1 is read in most modern codes). [severity: high; citation: §165 C-O — lot-area-to-gross-floor ratio (ecode360.com/11659233)]
- SM-1 height-conditional residential-buffer setback: 10 ft additional setback per ft of building height above 65 ft from existing residential dwellings. A 75-ft (max) building 30 ft from a residential parcel is non-compliant — buffer would require 100 ft. Functions as a contextual height taper rather than a flat front-setback. [severity: medium; citation: §165 SM-1 (ecode360.com/11659413)]
- 2nd-class township governance — 5-member elected Board of Supervisors with staggered 6-year terms; professional township manager. MPC-governed (53 P.S. §10101 et seq.), not home-rule. First township in the PA corpus (other PA records: Pittsburgh / Philadelphia cities, Indiana borough, Connellsville city). [severity: medium; citation: PA Code 2nd-class township statute; Wikipedia Upper Merion Township; township About page]
- King of Prussia Mall + I-76 / I-276 (PA Turnpike) / US-202 corridor drives near-continuous ordinance amendment activity — the 2014 KPMU rezoning, 2015 commercial-districts rezoning (NC/LC/GC replacing C-1/C-2/C-3), and 2024 spectator-sport-facilities ordinance are all corridor-driven. Treat the eCode360 'current through' date as load-bearing for any underwriting use; freshness_tier=standard (90-day TTL). [severity: high; citation: ecode360.com/UP0975 'current through 2025-03-13' header observed 2026-04-26]
- Schuylkill River + Valley Forge National Historical Park (NPS, ~1,300 acres) form the township's northern and western boundaries. NPS land use is sui generis (not subject to township zoning); the federal park footprint substantially constrains the township's developable land in the Valley Forge / Gulph Mills sector. Federal-overlay refs are global, not city-attached. [severity: low; citation: Valley Forge NHP boundary; Wikipedia Upper Merion Township]
- FIPS uses the 10-digit Census GeoID (4209179136 = state 42 + county 091 + sub-county 79136) because Upper Merion is a township minor civil division, not a Census Place. Pittsburgh's record uses a 7-digit Place FIPS (4261000); the two should not be compared as if the same code class. [severity: low; citation: U.S. Census Bureau QuickFacts page for Upper Merion township]
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §165
- [2] §165
- [3] §165
- [4] §165-11
- [5] i
- [6] z
- [7] §165
Research status
Publication gates
| primary url present | passed | |
|---|---|---|
| no aggregator cited | passed | |
| confidence tags full form | passed | |
| overlays have parameters trigger confidence | passed | |
| preempt section city specific | passed |
Other cities in this state