Overview
| residential | Use-type letter codes with no encoded density or lot size: AG (Agricultural), RR-1/RR-2 (Rural Residential tiers), R-1 (Single-Family Low Density), R-1D (Residential District — gentle density), R-2 (Mixed-Density), R-3 (Multi-Family Medium), R-4 (Multi-Family High), RM (Mobile Home) |
|---|---|
| commercial | C-O (Office), C-1 (Limited), C-2 (Community), CBD (Kearney Center Mixed Use), C-3 (General), BP (Business Park) |
| industrial | M-1 (Limited Industrial), M-2 (General Industrial) |
| mixed_use | UC (Mixed Use Urban Corridor), M-U (Mixed Use special district) |
19 base zoning districts + 1 special district (M-U) + 8 overlay districts: PD (Planned Development), TND (Traditional Neighborhood Development), RC (Rural Conservation Development), ND (Neighborhood Conservation), ND-1 (Pioneer Park Neighborhood Conservation), FP/FW (Floodplain/Floodway), AV (Aviation), W (Wellhead Protection). PD overlay is most-frequently used tool for residential and commercial development solutions. Chapter numbering reflects ULDO structure: Chapter 15=AG, 16=RR-1, 17=not retrieved, 18=RR-2, 19=R-1, 19A=R-1D, 20=R-2, 21=R-3, 22=R-4; commercial and industrial chapters not individually retrieved due to Municode gating.
- Naming convention anomaly: Chapter numbers directly parallel district codes (Ch.15=AG, Ch.16=RR-1, Ch.18=RR-2, Ch.19=R-1). This creates a direct chapter→district lookup but creates gaps (Chapter 17 not identified in available sources — possibly reserved or PD/overlay chapter).
- R-1 side yard is formula-based (10% of lot width at the 25 ft setback line), not a single fixed value. The minimum floor is 7 ft (confirmed §19-102 via Board of Adjustment 2014). Corner lots have 25 ft street-side setbacks that may confuse with formula-based interior side yard.
- R-1D has NO minimum lot size requirement — this is highly unusual and explicitly designed for gentle-density infill. Confirmed by Affordable Housing Report 2025.
+ 5 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| AG | Agricultural District | ag | [{'variant': '1-family-units', 'value': 435600, 'note': '10 acres'}, {'variant': 'other-permitted-uses', 'value': 871200, 'note': '20 acres'}] sf[1] | [{'variant': '1-family-units', 'value': 35}, {'variant': 'other-permitted-uses', 'value': 45}] ft[2] | — | — | — | —[3] | — / — / — |
| RR-1 | Rural Residential District (Rural Standards) | res_sf | 130,680 sf[4] | 35 ft[5] | — | — | — | —[6] | — / — / — |
| RR-2 | Rural Residential District (Intermediate Standards) | res_sf | [{'variant': '1-family-units', 'value': 76230, 'note': '1.75 acres; NDEQ approval required for lots <3 acres with individual well/septic'}, {'variant': 'other-permitted-uses', 'value': 130680, 'note': '3.0 acres'}] sf[7] | 35 ft[8] | 20[9] | — | — | —[10] | — / — / — |
| R-1 | Urban Residential Single-Family District (Low Density) | res_sf | — | — | — | — | —[11] | —[12] | — / — / — |
| R-1D | Residential District | res_sf | —[13] | — | — | — | 12[14] | —[15] | — / — / — |
| R-2 | Urban Residential Mixed-Density District | res_mf | — | — | — | — | — | —[16] | — / — / — |
| R-3 | Urban Residential Multi-Family District (Medium Density) | res_mf | — | — | — | — | — | —[17] | — / — / — |
| R-4 | Urban Residential Multi-Family District (High Density) | res_mf | — | — | — | — | — | —[18] | — / — / — |
| RM | Mobile Home Residential District | res_mfh | — | — | — | — | — | —[19] | — / — / — |
| UC | Mixed Use Urban Corridor District | mu | — | — | — | — | — | —[20] | — / — / — |
| C-O | Office District | com_office | — | — | — | — | — | —[21] | — / — / — |
| C-1 | Limited Commercial District | com | — | — | — | — | — | —[22] | — / — / — |
| C-2 | Community Commercial District | com | — | — | — | — | — | —[23] | — / — / — |
| CBD | Kearney Center Mixed-Use District | cbd | — | — | — | — | — | —[24] | — / — / — |
| C-3 | General Commercial District | com | — | — | — | — | — | —[25] | — / — / — |
| BP | Business Park District | com_park | — | — | — | — | — | —[26] | — / — / — |
| M-1 | Limited Industrial District | ind | — | — | — | — | — | —[27] | — / — / — |
| M-2 | General Industrial District | ind | — | — | — | — | — | —[28] | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Applied city-wide on developer petition; minimum 2-acre threshold for M-U special district classification; no geographic minimum for PD overlay on residential or commercial
Applied by application; build-to lines 5-20 ft, individual lot dimensions may be reduced to 80% of underlying district requirement
Areas with distinctive landforms within RR-1 and RR-2 zones; designated on zoning map
Historic infill areas; city-designated conservation neighborhoods
Pioneer Park neighborhood — city-designated historic/conservation area
FEMA-mapped Special Flood Hazard Areas (100-year floodplain) and floodway within Kearney; primarily Platte River / Kearney Canal drainages
Areas within approach/departure zones for Kearney Regional Airport (EAR — IATA); height restrictions based on FAA Part 77 imaginary surfaces
Wellhead Protection Zones as mapped per Nebraska DEQ / EPA Wellhead Protection Program; affects AG, RR-1, RR-2 districts
State preemptions
Adopted building codes
NEC statewide; others local
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-05-26 | retrieved at | Research date — Municode SPA blocked; dimensional data sourced from Ord. 8321 PDF, City Affordable Housing Report 2025 (NE Legislature archive), and Board of Adjustment minutes 2014 |
Quirks & notes
- Naming convention anomaly: Chapter numbers directly parallel district codes (Ch.15=AG, Ch.16=RR-1, Ch.18=RR-2, Ch.19=R-1). This creates a direct chapter→district lookup but creates gaps (Chapter 17 not identified in available sources — possibly reserved or PD/overlay chapter).
- R-1 side yard is formula-based (10% of lot width at the 25 ft setback line), not a single fixed value. The minimum floor is 7 ft (confirmed §19-102 via Board of Adjustment 2014). Corner lots have 25 ft street-side setbacks that may confuse with formula-based interior side yard.
- R-1D has NO minimum lot size requirement — this is highly unusual and explicitly designed for gentle-density infill. Confirmed by Affordable Housing Report 2025.
- Kearney does not allow ADUs as of the 2025 Affordable Housing Report. Staff evaluated in 2024 but did not adopt due to strong neighborhood opposition. No MMHA by-right ADU mandate has been enacted by the Nebraska Legislature (the 2023-2025 refiles adding by-right teeth all failed cloture).
- M-1 (Limited Industrial) is the largest single zoning district by area at 11.67%, followed by R-1 at 35.15% residential.
- Template-bleed confirmed in prior v1 record: all 8 districts showed identical dimensions (5000 sf / 35 ft / 0.5 FAR / 0.5 coverage / 2 parking / 25/25/10 setbacks). These values were fabricated. Actual dimensions confirmed from primary sources are substantially different (RR-1 = 3 acres minimum lot, not 5,000 sf; R-1 side yard = 7 ft minimum, not 25 ft).
- Kearney is the county seat of Buffalo County. FIPS: state 31, county 019, place 25055. 7-digit Census place code: 3125055.
- Municode SPA gating: library.municode.com returns HTTP 403 for scripted access. Wayback Machine caches only Angular SPA shells with no rendered content. Primary dimensional data recovered via: (1) Ordinance No. 8321 PDF (mcclibraryfunctions.azurewebsites.us), (2) City Affordable Housing Report 2025 (Nebraska Legislature archive), (3) Board of Adjustment minutes 2014. Non-residential district dimensional standards remain under_review due to this blocker.
Formulas
Definitions
- height
- Grade to highest point of structure.
- lot_coverage
- Building footprint / lot area (maximum building coverage).
- impervious_cover
- Total impervious surface / lot area.
- far
- Gross floor area / lot area (not the primary Kearney residential regulator; lot coverage and density govern residential).
- du_ac
- Dwelling units per gross acre.
- setback_front
- Front property line to nearest building face (minimum yards).
- setback_side
- Side property line to nearest building face; R-1 side yard = 10% of lot width at the 25 ft setback line (formula-based, minimum 7 ft confirmed by §19-102 and Board of Adjustment minutes 2014-08-25).
- setback_rear
- Rear property line to nearest building face.
- setback_street_side
- Street-side property line setback on corner lots.
- parking
- Spaces per dwelling unit per Chapter 47 Supplemental Use Regulations.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- buildable_width_ft
lot_width_ft - setback_side_ft * 2- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- max_stories_approx
max_height_ft / 10
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §15-102
- [2] §15-102
- [3] n
- [4] §16-102
- [5] §16-102
- [6] n
- [7] §18-102
- [8] §18-102
- [9] §18-102
- [10] n
- [11] n
- [12] n
- [13] §R-1D-102
- [14] §R-1D
- [15] n
- [16] n
- [17] n
- [18] n
- [19] n
- [20] n
- [21] n
- [22] n
- [23] n
- [24] n
- [25] n
- [26] n
- [27] n
- [28] n
Research status
Publication gates
| primary url present | passed | source.code_source = https://library.municode.com/ne/kearney/codes/code_of_ordinances — https URL, canonical Municode page for City of Kearney NE, not an aggregator domain |
|---|---|---|
| no aggregator cited | passed | scan clean — no reference to Zoneomics, Steadily, SitePlanGuide, SitePlanCreator, Propwire, Zonara, or Unzoned in record body. Zoneomics appears in quirks note only as a rejected source with explicit disqualification. |
| confidence tags full form | passed | All confirmed fields carry §-citation: AG §15-102 (full table: 10 confirmed values), RR-1 §16-102 (6 confirmed), RR-2 §18-102 (9 confirmed), R-1 §19-102 (4 setbacks confirmed), R-1D max_density §R-1D, R-1 min_lot null (no fabricated value). All partial fields carry retrieval_failure_reason. 0 bare confirmed fields without citations. 27+ confirmed/partial fields with citations or documented absences. |
| overlays have parameters trigger confidence | passed | 8 overlays documented. Each has: parameters[] (non-empty), geographic_trigger (non-empty), status (confirmed or partial), citation. PD=confirmed, TND=confirmed, RC=confirmed §16-101/§18-101, ND=partial with citation, ND-1=partial with citation, FP/FW=partial with citation, AV=partial with citation, W=confirmed §15-102/§16-102/§18-102. All 8 meet gate 4 minimum requirements. |
| preempt section city specific | passed | Nebraska is not in the active-preemption gate-5 state list (CA/TX/FL/OR/WA/CO/MN/MT/UT/AZ/NJ/CT). However, 6 Nebraska preemption laws documented with city-specific qualifying_condition_checked values: §19-904 (op=always, first-class city confirmed), MMHA §19-5501 (34,246 pop >= 20,000; compliance reports filed), §18-1758 STR (op=always), LB 266 rent-control (op=always), LB 614 ETJ farm-building (first-class + ETJ), §19-929 ETJ framework (2-mile ETJ confirmed). All qualifying_condition_checked entries contain numeric inputs, vintage, and threshold comparison. |
Data quality
- R-1 min_lot_sf, min_lot_width_ft, max_height_ft, lot_coverage_pct — Municode §19-102 table gated
- R-1D setbacks and lot width — Municode SPA gated
- R-2, R-3, R-4 all dimensional standards — amended 2022, Municode SPA gated
- RM, UC dimensional standards — Municode SPA gated
- All commercial (C-O, C-1, C-2, CBD, C-3, BP) dimensional standards — Municode SPA gated
- All industrial (M-1, M-2) dimensional standards — Municode SPA gated
- Chapter 47 parking table — not retrieved
- FP/FW overlay: freeboard requirement and specific flood zone map adoption date not confirmed
Known issues