Overview
| residential | lot-size-encoded (R1-9000, R1-6000 encode minimum lot sf); R-Flex uses intensity index |
|---|---|
| mixed_use | letter-code (MX-N = neighborhood, MX-T = transition, MX-M = medium, MX-L = large, MX-I = institutional) |
| industrial | letter-code (BP = business park, LI = light, GI = general) |
RetoolCOS 2023 complete rewrite of 1990s-era ordinance. Euclidean base with 10 overlay districts. R-Flex districts are 2023 additions replacing older transitional categories. R-MH no longer exists as a separate district. FBZ Form-Based Zone district exists but is applied via a separately adopted form-based plan.
- RetoolCOS 2023 was a complete rewrite from a 1990s-era code — the new UDC (effective June 5, 2023) introduced R-Flex districts, eliminated R-MH as a standalone district, and added 10 overlay districts including WUI-O and ADU-O that did not exist before.
- R-MH (Manufactured/Mobile Home) district does NOT exist in the 2023 UDC — it was subsumed into R-Flex Low and other residential categories. Any reference to R-MH is v1_legacy template bleed from the pre-2023 code.
- NNA-O is the only overlay district integrated directly into the base district use table (§7.3.102) rather than a separate modification table — unusual in this code structure and noted by planning staff.
+ 10 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| A | Agricultural | ag | 217,800 sf[4] | 35 ft[5] | — | — | — | 2[6] | 25[1] / 10[2] / 35[3] |
| R-E | Single-Family Estate | res_sf | 20,000 sf[10] | 35 ft[11] | 0.3[12] | — | — | 2[13] | 25[7] / 10[8] / 25[9] |
| R1-9000 | Single-Family Large | res_sf | 9,000 sf[17] | 35 ft[18] | [{'variant': '5000-6500sf-lot', 'value': 0.55}, {'variant': '6501-7500sf-lot', 'value': 0.5}, {'variant': '7501-8500sf-lot', 'value': 0.45}, {'variant': '8501sf-plus-lot', 'value': 0.4}][19] | — | — | 2[20] | —[14] / 5[15] / 20[16] |
| R1-6000 | Single-Family Medium | res_sf | 6,000 sf[24] | 35 ft[25] | [{'variant': '5000-6500sf-lot', 'value': 0.55}, {'variant': '6501-7500sf-lot', 'value': 0.5}, {'variant': '7501-8500sf-lot', 'value': 0.45}, {'variant': '8501sf-plus-lot', 'value': 0.4}][26] | — | — | 2[27] | —[21] / 5[22] / 15[23] |
| R-2 | Two-Family | res_sf | —[31] | 35 ft[32] | 0.4[33] | — | — | 2[34] | —[28] / 5[29] / 15[30] |
| R-4 | Multi-Family Low | res_mf | — | 40 ft[38] | 0.45[39] | — | 8[40] | [{'variant': 'studio-or-1br', 'value': 1}, {'variant': '2br', 'value': 1.5}, {'variant': '3br-plus', 'value': 2}][41] | 20[35] / 5[36] / 15[37] |
| R-5 | Multi-Family High | res_mf | — | 50 ft[45] | 0.5[46] | — | 25[47] | [{'variant': 'studio-or-1br', 'value': 1}, {'variant': '2br', 'value': 1.5}, {'variant': '3br-plus', 'value': 2}][48] | 20[42] / 5[43] / 15[44] |
| R-Flex Low | Flex Residential Low | res_sf | 2,000 sf[52] | [{'variant': 'residential', 'value': 35}, {'variant': 'non-residential', 'value': 45}] ft[53] | — | — | 6[54] | — | —[49] / 1[50] / 10[51] |
| R-Flex Medium | Flex Residential Medium | res_mf | 1,500 sf[58] | 45 ft[59] | — | — | —[60] | — | —[55] / 1[56] / 10[57] |
| R-Flex High | Flex Residential High | res_mf | 1,000 sf[64] | [{'variant': 'residential', 'value': 65}, {'variant': 'non-residential', 'value': 45}] ft[65] | — | — | —[66] | — | —[61] / 1[62] / 10[63] |
| OR | Office Residential | off | 5,000 sf[70] | 35 ft[71] | 0.5[72] | — | — | — | 25[67] / 5[68] / 20[69] |
| MX-N | Mixed-Use Neighborhood | mu | — | 45 ft[76] | — | — | — | — | —[73] / 10[74] / 15[75] |
| MX-T | Mixed-Use Transition | mu | — | 60 ft[80] | — | — | — | — | 25[77] / 5[78] / 25[79] |
| MX-M | Mixed-Use Medium Scale | mu | — | 50 ft[84] | — | — | — | — | —[81] / 20[82] / 15[83] |
| MX-L | Mixed-Use Large Scale | mu | — | [{'variant': 'general', 'value': 65}, {'variant': 'arterial-frontage', 'value': 85, 'note': 'Lots with arterial frontage may reach 85 ft'}] ft[88] | — | — | — | — | —[85] / —[86] / —[87] |
| MX-I | Mixed-Use Institutional | mu | — | 65 ft[92] | — | — | — | — | —[89] / 20[90] / 20[91] |
| BP | Business Park | ind | — | 45 ft[96] | — | — | — | — | 20[93] / 10[94] / 25[95] |
| LI | Light Industrial | ind | — | 60 ft[98] | — | — | — | — | 20[97] / — / — |
| GI | General Industrial | ind | — | 80 ft[100] | — | — | — | — | 20[99] / — / — |
Confidence: confirmed partial under review not found
Overlays
Defined area around Colorado Springs Municipal Airport (KCOS); subzones: APZ-1, APZ-2, Aircraft Navigation, Airport Noise Contour (65+ DNL), Runway Protection Zone shown on official AP-O map
| height_restrictions | Per FAA Part 77 surfaces and approach slopes; FAA Form 7460-1 required where applicable |
|---|---|
| noise | 65 DNL zone requires 30 dBA interior noise level reduction for residential development; noise reduction certificate required |
| avigation_easement | Required as condition of discretionary approvals within the overlay |
| incompatible_uses | Restrictions vary by subzone; APZ-1 most restrictive for incompatible uses |
Properties adjacent to or affected by USAF Academy airfield operations north of Colorado Springs; extent defined on official AF-O map per FAA Part 77 surfaces
| purpose | Maintains safety of navigable airspace around USAF Academy airfield in compliance with 14 CFR (FAA regulations) |
|---|---|
| height_restrictions | Per FAA Part 77 surfaces; federal aeronautical standards govern |
| federal_program | Tied to FAA/USAF coordination; federal standards prevail |
Areas with intermittent and perennial streams providing wildlife habitat, riparian vegetation, and water quality functions; shown on official SS-O map
| review_criteria | 11 review criteria: natural feature protection, wildlife preservation, stream bank stabilization, riparian buffers, and 7 additional criteria |
|---|---|
| design_guidelines | Must comply with Streamside Design Guidelines (separate adopted document) |
| impact_standard | Development must demonstrate no significant adverse impact to stream functions |
Properties within the Wildland-Urban Interface as designated on official WUI-O map based on wildfire hazard proximity; map updated per state fire risk standards
| fuels_management | All properties within WUI-O must comply with Wildland Fuels Management Requirements in Appendix K of Colorado Springs Fire Prevention Code |
|---|---|
| vegetation_clearance | Defensible space and vegetation clearance requirements |
| construction_standards | Wildfire-resistant building materials and roof coverings per Ordinance 23-14 (Appendix K effective 2024) |
| state_coordination | Coordinates with Colorado Wildfire Resiliency Code Board requirements (SB 22-007) |
Applied to parcels in qualifying residential base districts citywide per HB 24-1152 compliance; applied by ADU-O map designation
| by_right | ADUs allowed by-right in single-family and multi-family residential zones |
|---|---|
| owner_occupancy | No owner-occupancy requirement per state preemption HB 24-1152 |
| design_standards | ADU design standards may not be more restrictive than standards for the primary structure |
| hoa_preemption | HOA prohibitions of state-compliant ADUs are unenforceable per HB 24-1152 §3 |
Generally south of Garden of the Gods/Austin Bluffs Pkwy, east of Monument Creek and Cascade Avenue, west of Weber Street and Stone Avenue, north of Old North End at railroad ROW; implements North Nevada Avenue Master Plan
| use_table | NNA-O has its own use column integrated directly into the base district use table at §7.3.102 — the only overlay treated this way in the UDC |
|---|---|
| goals | Mixed business types serving residents and regional economic magnet; improved roadways and expanded transit; expanded housing options; integrated infrastructure |
| permitted_uses | Modified use permissions per NNA-O column in §7.3.102 Use Table |
Specific subareas where City Council has adopted design standards; applied by official ADS-O map
| design_standards | Establishes design standards specific to a defined geographic area; may modify or supplement base zone design, massing, or materials standards |
|---|
Properties designated by City Council through Historic Preservation Board review; includes individual landmarks and locally-designated historic districts
| board_review | Historic Preservation Board review required for all exterior changes to designated properties |
|---|---|
| dimensional_relief | Board may recommend: reduced setbacks, height limit waiver, alley parking, up to 100% compact parking, up to 50% parking reduction |
| rezoning | Strict rezoning criteria at §7.5.704.D apply to HP-O properties |
| permissive_relief | HP-O can be LESS restrictive than base zone on dimensional standards where preservation objectives require it |
Areas near downtown Colorado Springs; applied by City Council action; shown on official HR-O map
| high_rise | Allows high-rise buildings with special height, floor area, and bulk limitations |
|---|---|
| specific_limits | Specific height maximum and FAR parameters established by adoption ordinance; values not available in quick-reference sources — require direct review of overlay map and ordinance |
Areas with ridgelines, bluffs, rock outcroppings, significant slopes, wildlife habitat, and geologic conditions; designated on official Hillside Overlay map
| design_manual | Must comply with Hillside Development Design Manual (separate adopted document) |
|---|---|
| terrain | Terrain disturbance minimization required; natural feature integration; visual impact mitigation |
| standards | Standards for grading limits, retaining walls, vegetation preservation, and slope-sensitive construction |
State preemptions
Adopted building codes
Denver & state buildings; home rule elsewhere
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-05-27 | retrieved at | |
| 2024-12-01 | amendment effective | ADU Ordinance No. 24-__ amending §7.2.204, §7.2.205, §7.2.206 per HB 24-1152 |
| 2023-06-05 | effective | Ordinance No. 23-01 effective date |
| 2023-02-14 | adoption | Ordinance No. 23-01 adopting RetoolCOS UDC rewrite |
Quirks & notes
- RetoolCOS 2023 was a complete rewrite from a 1990s-era code — the new UDC (effective June 5, 2023) introduced R-Flex districts, eliminated R-MH as a standalone district, and added 10 overlay districts including WUI-O and ADU-O that did not exist before.
- R-MH (Manufactured/Mobile Home) district does NOT exist in the 2023 UDC — it was subsumed into R-Flex Low and other residential categories. Any reference to R-MH is v1_legacy template bleed from the pre-2023 code.
- NNA-O is the only overlay district integrated directly into the base district use table (§7.3.102) rather than a separate modification table — unusual in this code structure and noted by planning staff.
- HP-O can be LESS restrictive than the base zone on dimensional standards — Historic Preservation Board may recommend setback waivers or height limit waivers if preservation objectives require it. This is the inverse of typical overlay behavior.
- Lot coverage in R1-9000 and R1-6000 is lot-size-varying with 4 tiers (55% for 5,000–6,500 sf lots down to 40% for 8,501+ sf lots) — not a single value per district.
- Front setbacks in R1-9000, R1-6000, R-2 are contextual formulas (greater of fixed minimum OR average of adjacent developed properties) — not reducible to single fixed-foot values.
- FAR is not a primary dimensional standard in Colorado Springs UDC. Lot coverage and height are the primary bulk controls. No FAR values in Tables 7.4.2-A, 7.4.2-B, or 7.4.2-C.
- Colorado Springs is surrounded by three major military installations: Peterson Space Force Base (east), Fort Carson (south), USAF Academy (north). AF-O covers Academy area; AP-O covers Colorado Springs Municipal Airport. Peterson/Fort Carson AICUZ noise contours and their relationship to city zoning not yet extracted.
- City is in PPACG MPO — all three major CO 2024 housing preemption laws (HB 24-1152 ADU, HB 24-1313 TOD density, HB 24-1304 parking) apply. City adopted compliance ordinances in late 2024 / August 2025 without explicitly waiving home-rule authority.
- R-Flex districts have density ranges tied to the Comprehensive Land Use Plan rather than fixed UDC maximums — plan designation controls density ceiling within the R-Flex envelope.
- Colorado Springs airport (KCOS) has a FAA Part 150 noise compatibility program — the 65 DNL noise contour triggers 30 dBA interior noise reduction requirement for residential development within that contour.
- Code supplement as of research date: 2025 S-18 on AMLegal (codelibrary.amlegal.com/codes/coloradospringsco). EncodePlus (online.encodeplus.com/regs/coloradosprings-co) provides an alternate access path not blocked by Cloudflare when AMLegal returns 403.
- Manufactured home park parking: 1 per manufactured home space (Table 7.4.10-A). Tiny House Community: 1 per DU. These uses are now permitted in MX and R-Flex districts rather than a dedicated R-MH district.
Formulas
Definitions
- height
- Measured from finished grade to highest point of roof per §7.6.202. UDC Tables 7.4.2-A through 7.4.2-D govern per district.
- lot_coverage
- Maximum percentage of total lot surface area covered by improvements divided by total lot area. Expressed as percent in UDC; stored here as decimal fraction per schema standard.
- far
- Not a primary regulatory tool in Colorado Springs UDC. Lot coverage and height are the primary bulk controls. No FAR values in Tables 7.4.2-A through 7.4.2-C.
- du_ac
- Maximum residential density per acre. Specified for R-2, R-4, R-5; R-Flex districts have density ranges per Land Use Plan designation.
- impervious_cover
- setback_front
- Measured from back of sidewalk, curb, or property line, whichever is lesser per §7.4.2 notes.
- setback_side
- Interior side measured from property line. Corner lot side-street setback is separately specified.
- setback_rear
- Measured from rear property line.
- parking
- Minimum off-street motor vehicle spaces per Table 7.4.10-A (§7.4.1003). HB 24-1304 waives minimums for qualifying MF/MX within one-quarter mile of transit effective August 2025.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- max_gfa_sf
- parking_required
units * parking (where applicable per Table 7.4.10-A)
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §7.4.2
- [2] §7.4.2
- [3] §7.4.2
- [4] §7.4.2
- [5] §7.4.2
- [6] §7.4.1003
- [7] §7.4.2
- [8] §7.4.2
- [9] §7.4.2
- [10] §7.4.2
- [11] §7.4.2
- [12] §7.4.2
- [13] §7.4.1003
- [14] §7.4.2
- [15] §7.4.2
- [16] §7.4.2
- [17] §7.4.2
- [18] §7.4.2
- [19] §7.4.2
- [20] §7.4.1003
- [21] §7.2.204
- [22] §7.4.2
- [23] §7.4.2
- [24] §7.2.204
- [25] §7.4.2
- [26] §7.4.2
- [27] §7.4.1003
- [28] §7.2.205
- [29] §7.4.2
- [30] §7.4.2
- [31] §7.4.2
- [32] §7.4.2
- [33] §7.4.2
- [34] §7.4.1003
- [35] §7.4.2
- [36] §7.4.2
- [37] §7.4.2
- [38] §7.4.2
- [39] §7.4.2
- [40] §7.4.2
- [41] §7.4.1003
- [42] §7.4.2
- [43] §7.4.2
- [44] §7.4.2
- [45] §7.4.2
- [46] §7.4.2
- [47] §7.4.2
- [48] §7.4.1003
- [49] §7.4.2
- [50] §7.4.2
- [51] §7.4.2
- [52] §7.4.2
- [53] §7.4.2
- [54] §7.4.2
- [55] §7.4.2
- [56] §7.4.2
- [57] §7.4.2
- [58] §7.4.2
- [59] §7.4.2
- [60] §7.4.2
- [61] §7.4.2
- [62] §7.4.2
- [63] §7.4.2
- [64] §7.4.2
- [65] §7.4.2
- [66] §7.4.2
- [67] §7.4.2
- [68] §7.4.2
- [69] §7.4.2
- [70] §7.4.2
- [71] §7.4.2
- [72] §7.4.2
- [73] §7.4.2
- [74] §7.4.2
- [75] §7.4.2
- [76] §7.4.2
- [77] §7.4.2
- [78] §7.4.2
- [79] §7.4.2
- [80] §7.4.2
- [81] §7.4.2
- [82] §7.4.2
- [83] §7.4.2
- [84] §7.4.2
- [85] §7.4.2
- [86] §7.4.2
- [87] §7.4.2
- [88] §7.4.2
- [89] §7.4.2
- [90] §7.4.2
- [91] §7.4.2
- [92] §7.4.2
- [93] §7.4.2
- [94] §7.4.2
- [95] §7.4.2
- [96] §7.4.2
- [97] §7.4.2
- [98] §7.4.2
- [99] §7.4.2
- [100] §7.4.2
Research status
Publication gates
| primary url present | passed | code_source = https://codelibrary.amlegal.com/codes/coloradospringsco/latest/coloradosprings_co/0-0-0-1 — authoritative AMLegal host, https://, not an aggregator domain |
|---|---|---|
| no aggregator cited | passed | Full record scan clean — no Zoneomics, Steadily, SitePlanGuide, SiteDesignGuide, SitePlanCreator, Propwire, Zonara, or Unzoned domains cited anywhere |
| confidence tags full form | passed | 72 confirmed fields carry section citations (§7.4.2, §7.2.204, §7.2.205, §7.2.501.B, §7.2.603, §7.2.606, §7.2.608, §7.4.1003, §7.2.601, etc.); partial fields carry status=partial with reason; not_captured fields carry not_captured_reason |
| overlays have parameters trigger confidence | passed | All 10 overlays (AP-O, AF-O, SS-O, WUI-O, ADU-O, NNA-O, ADS-O, HP-O, HR-O, HS-O) have non-empty params{}, trigger, and confidence codes. ADS-O confidence p§7.2.607 and HR-O confidence p§7.2.609 are partial with explanatory notes. |
| preempt section city specific | passed | 5 CO preemption laws with city-specific qualifying_condition_checked containing numeric inputs (pop 493,554 ACS 2024), MPO membership verification (PPACG), vintage dates, and threshold comparisons. No bare stubs. |
Data quality
- MX-T, MX-M, MX-I, MX-L detailed permitted use lists not extracted (available at §7.2.3 series in full code)
- LI and GI side/rear setback details reference 'additional standards in Part 7.2.4' — not extracted from primary source
- HR-O specific height cap and FAR values require review of overlay adoption ordinance and official HR-O map
- ADS-O specific adopted geographic areas and their design parameters not enumerated
- Peterson Space Force Base and Fort Carson AICUZ noise contours and their relationship to city zoning not extracted — may create federal_state_conflict with CO preemption laws in affected areas
- Public/institutional base districts (PF Public Facilities, APD Airport Planned Development, PK Public Parks, FBZ Form-Based Zone) not researched in this pass
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.